Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/03 14:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -666,7 +666,7 @@ 666 666 667 667 (% style="color:blue" %)**AT Command: AT+3V3T** 668 668 669 -(% border="1" cellspacing="4" style="width:474px" %) 669 +(% border="1" cellspacing="4" style="width:474px;background-color:#F2F2F2" %) 670 670 |=(% style="width: 154px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 201px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 116px;background-color:#D9E2F3;color:#0070C0" %)**Response** 671 671 |(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=?|(% style="background-color:#f2f2f2; width:201px" %)Show 3V3 open time.|(% style="background-color:#f2f2f2; width:116px" %)((( 672 672 0 ... ... @@ -685,7 +685,7 @@ 685 685 686 686 (% style="color:blue" %)**AT Command: AT+5VT** 687 687 688 -(% border="1" cellspacing="4" style="width:470px" %) 688 +(% border="1" cellspacing="4" style="width:470px;background-color:#F2F2F2" %) 689 689 |=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 114px;background-color:#D9E2F3;color:#0070C0" %)**Response** 690 690 |(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=?|(% style="background-color:#f2f2f2; width:196px" %)Show 5V open time.|(% style="background-color:#f2f2f2; width:114px" %)((( 691 691 0 ... ... @@ -704,7 +704,7 @@ 704 704 705 705 (% style="color:blue" %)**AT Command: AT+12VT** 706 706 707 -(% border="1" cellspacing="4" style="width:443px" %) 707 +(% border="1" cellspacing="4" style="width:443px;background-color:#F2F2F2" %) 708 708 |=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 199px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 83px;background-color:#D9E2F3;color:#0070C0" %)**Response** 709 709 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)((( 710 710 0 ... ... @@ -734,7 +734,7 @@ 734 734 735 735 Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value. 736 736 737 -**AT Command: AT** **+PROBE** 737 +(% style="color:blue" %)**AT Command: AT** **+PROBE** 738 738 739 739 AT+PROBE=aabb 740 740 ... ... @@ -746,7 +746,7 @@ 746 746 747 747 (A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C) 748 748 749 -(% border="1" cellspacing="4" style="width:510px" %) 749 +(% border="1" cellspacing="4" style="width:510px;background-color:#F2F2F2" %) 750 750 |(% style="background-color:#d9e2f3; color:#0070c0; width:154px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:269px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Response** 751 751 |(% style="background-color:#f2f2f2; width:154px" %)AT +PROBE =?|(% style="background-color:#f2f2f2; width:269px" %)Get or Set the probe model.|(% style="background-color:#f2f2f2" %)0 752 752 OK ... ... @@ -759,7 +759,7 @@ 759 759 |(% style="background-color:#f2f2f2; width:154px" %)AT +PROBE =0101|(% style="background-color:#f2f2f2; width:269px" %)Set pressure transmitters mode, first type(A).|(% style="background-color:#f2f2f2" %)OK 760 760 |(% style="background-color:#f2f2f2; width:154px" %)AT +PROBE =0000|(% style="background-color:#f2f2f2; width:269px" %)Initial state, no settings.|(% style="background-color:#f2f2f2" %)OK 761 761 762 -**Downlink Command: 0x08** 762 +(% style="color:blue" %)**Downlink Command: 0x08** 763 763 764 764 Format: Command Code (0x08) followed by 2 bytes. 765 765 ... ... @@ -782,7 +782,7 @@ 782 782 (% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535 783 783 (% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120 784 784 785 -(% border="1" cellspacing="4" style="width:510px" %) 785 +(% border="1" cellspacing="4" style="width:510px;background-color:#F2F2F2" %) 786 786 |(% style="background-color:#d9e2f3; color:#0070c0; width:160px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:215px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Response** 787 787 |(% style="background-color:#f2f2f2; width:160px" %)AT+STDC=?|(% style="background-color:#f2f2f2; width:215px" %)Get the mode of multiple acquisitions and one uplink.|(% style="background-color:#f2f2f2" %)1,10,18 788 788 OK