Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -133,8 +133,11 @@ 133 133 * Measuring Range: Measure range can be customized, up to 100m. 134 134 * Accuracy: 0.2% F.S 135 135 * Long-Term Stability: ±0.2% F.S / Year 136 +* Overload 200% F.S 137 +* Zero Temperature Drift: ±2% F.S) 138 +* FS Temperature Drift: ±2% F.S 136 136 * Storage temperature: -30℃~~80℃ 137 -* Operating temperature: 0℃~~5 0℃140 +* Operating temperature: -40℃~~85℃ 138 138 * Material: 316 stainless steels 139 139 140 140 == 1.5 Probe Dimension == ... ... @@ -194,20 +194,19 @@ 194 194 [[image:1675071855856-879.png]] 195 195 196 196 197 -(% border="1" cellspacing="4" style="width:510px" %) 198 -|=(% style="width: 167px; background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action**199 -|(% style=" background-color:#f2f2f2;width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2;width:117px" %)Send an uplink|(% style="background-color:#f2f2f2;width:225px" %)(((200 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 201 +|=(% style="width: 167px;" %)**Behavior on ACT**|=(% style="width: 117px;" %)**Function**|=(% style="width: 225px;" %)**Action** 202 +|(% style="width:167px" %)Pressing ACT between 1s < time < 3s|(% style="width:117px" %)Send an uplink|(% style="width:225px" %)((( 200 200 If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once. 201 201 Meanwhile, BLE module will be active and user can connect via BLE to configure device. 202 202 ))) 203 -|(% style=" background-color:#f2f2f2;width:167px" %)Pressing ACT for more than 3s|(% style="background-color:#f2f2f2;width:117px" %)Active Device|(% style="background-color:#f2f2f2;width:225px" %)(((204 -(% style=" background-color:#f2f2f2; color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network.205 -(% style=" background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.206 +|(% style="width:167px" %)Pressing ACT for more than 3s|(% style="width:117px" %)Active Device|(% style="width:225px" %)((( 207 +(% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. 208 +(% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 206 206 Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network. 207 207 ))) 208 -|(% style=" background-color:#f2f2f2;width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2;width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2;width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NAis in Deep Sleep Mode.211 +|(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 209 209 210 - 211 211 == 1.9 Pin Mapping == 212 212 213 213 ... ... @@ -390,6 +390,9 @@ 390 390 [[image:1675144608950-310.png]] 391 391 392 392 395 +=== === 396 + 397 + 393 393 === 2.3.3 Battery Info === 394 394 395 395 ... ... @@ -414,6 +414,7 @@ 414 414 |PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 415 415 |PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure 416 416 422 + 417 417 The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value. 418 418 419 419 ... ... @@ -420,7 +420,7 @@ 420 420 === 2.3.5 0~~20mA value (IDC_IN) === 421 421 422 422 423 -The output value from **Pressure Probe**, use together with Probe Model to get the pressure value or water level.429 +The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level. 424 424 425 425 (% style="color:#037691" %)**Example**: 426 426 ... ... @@ -427,11 +427,6 @@ 427 427 27AE(H) = 10158 (D)/1000 = 10.158mA. 428 428 429 429 430 -Instead of pressure probe, User can also connect a general 4~~20mA in this port to support different types of 4~~20mA sensors. below is the connection example: 431 - 432 -[[image:image-20230225154759-1.png||height="408" width="741"]] 433 - 434 - 435 435 === 2.3.6 0~~30V value ( pin VDC_IN) === 436 436 437 437 ... ... @@ -464,7 +464,6 @@ 464 464 465 465 0x01: Interrupt Uplink Packet. 466 466 467 - 468 468 === (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 === 469 469 470 470 ... ... @@ -563,35 +563,34 @@ 563 563 [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]] 564 564 565 565 566 -= 3. Configure PS-LB = 566 += 3. Configure PS-LB via AT Command or LoRaWAN Downlink = 567 567 568 -== 3.1 Configure Methods == 569 569 570 - PS-LB-NAsupports belowconfiguremethod:569 +Use can configure PS-LB via AT Command or LoRaWAN Downlink. 571 571 572 -* AT Command via Bluetooth Connection (**Recommand Way**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 573 -* AT Command via UART Connection : See [[FAQ>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/#H7.FAQ]]. 574 -* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 571 +* AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]]. 572 +* LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 575 575 576 - == 3.2 GeneralCommands==574 +There are two kinds of commands to configure PS-LB, they are: 577 577 576 +* (% style="color:#037691" %)**General Commands** 577 + 578 578 These commands are to configure: 579 579 580 580 * General system settings like: uplink interval. 581 581 * LoRaWAN protocol & radio related command. 582 582 583 -They are same for all Dragino Device swhich support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:583 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 584 584 585 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>> url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]585 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 586 586 587 587 588 +* (% style="color:#037691" %)**Commands special design for PS-LB** 588 588 589 -== 3.3 Commands special design for PS-LB == 590 - 591 591 These commands only valid for PS-LB, as below: 592 592 593 593 594 -== =3.3.1 Set Transmit Interval Time ===593 +== 3.1 Set Transmit Interval Time == 595 595 596 596 597 597 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -619,7 +619,7 @@ 619 619 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 620 620 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 621 621 622 -== =3.3.2 Set Interrupt Mode ===621 +== 3.2 Set Interrupt Mode == 623 623 624 624 625 625 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -650,7 +650,7 @@ 650 650 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 651 651 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 652 652 653 -== =3.3.3Set the output time ===652 +== 3.3 Set the output time == 654 654 655 655 656 656 Feature, Control the output 3V3 , 5V or 12V. ... ... @@ -719,7 +719,7 @@ 719 719 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 720 720 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 721 721 722 -== =3.3.4 Set the Probe Model ===721 +== 3.4 Set the Probe Model == 723 723 724 724 725 725 Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value. ... ... @@ -749,6 +749,7 @@ 749 749 |AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK 750 750 |AT +PROBE =0000|Initial state, no settings.|OK 751 751 751 + 752 752 **Downlink Command: 0x08** 753 753 754 754 Format: Command Code (0x08) followed by 2 bytes. ... ... @@ -756,7 +756,7 @@ 756 756 * Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 757 757 * Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 758 758 759 -== =3.3.5=759 +== 3.5 Multiple collections are one uplink(Since firmware V1.1) == 760 760 761 761 762 762 Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. ... ... @@ -790,6 +790,7 @@ 790 790 OK 791 791 ))) 792 792 793 + 793 793 (% style="color:blue" %)**Downlink Command: 0xAE** 794 794 795 795 Format: Command Code (0x08) followed by 5 bytes. ... ... @@ -796,34 +796,107 @@ 796 796 797 797 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 798 798 799 -= 4. Battery & PowerConsumption=800 += 4. Battery & how to replace = 800 800 801 - PS-LB-NAuses ER26500 + SPC1520batterypack. See below link for detail information about the batteryinfo and how to replace.802 +== 4.1 Battery Type == 802 802 803 - [[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 804 804 805 +PS-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 805 805 806 - =5.OTAfirmwareupdate=807 +The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 807 807 809 +[[image:1675146710956-626.png]] 808 808 811 + 812 +Minimum Working Voltage for the PS-LB: 813 + 814 +PS-LB: 2.45v ~~ 3.6v 815 + 816 + 817 +== 4.2 Replace Battery == 818 + 819 + 820 +Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 821 + 822 +And make sure the positive and negative pins match. 823 + 824 + 825 +== 4.3 Power Consumption Analyze == 826 + 827 + 828 +Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 829 + 830 +Instruction to use as below: 831 + 832 +(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]] 833 + 834 +(% style="color:blue" %)**Step 2:**(%%) Open it and choose 835 + 836 +* Product Model 837 +* Uplink Interval 838 +* Working Mode 839 + 840 +And the Life expectation in difference case will be shown on the right. 841 + 842 +[[image:1675146895108-304.png]] 843 + 844 + 845 +The battery related documents as below: 846 + 847 +* [[Battery Dimension>>https://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]], 848 +* [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]] 849 +* [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]] 850 + 851 +[[image:image-20230131145708-3.png]] 852 + 853 + 854 +=== 4.3.1 Battery Note === 855 + 856 + 857 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 858 + 859 + 860 +=== 4.3.2 Replace the battery === 861 + 862 + 863 +You can change the battery in the PS-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 864 + 865 +The default battery pack of PS-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 866 + 867 + 868 += 5. Remote Configure device = 869 + 870 +== 5.1 Connect via BLE == 871 + 872 + 873 +Please see this instruction for how to configure via BLE: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]] 874 + 875 + 876 +== 5.2 AT Command Set == 877 + 878 + 879 + 880 += 6. OTA firmware update = 881 + 882 + 809 809 Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 810 810 811 811 812 -= 6. FAQ =886 += 7. FAQ = 813 813 814 -== 6.1 How to use AT Commandvia UARTto access device? ==888 +== 7.1 How to use AT Command to access device? == 815 815 816 816 817 817 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 818 818 819 819 820 -== 6.2 How to update firmware via UART port? ==894 +== 7.2 How to update firmware via UART port? == 821 821 822 822 823 823 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 824 824 825 825 826 -== 6.3 How to change the LoRa Frequency Bands/Region? ==900 +== 7.3 How to change the LoRa Frequency Bands/Region? == 827 827 828 828 829 829 You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]. ... ... @@ -830,13 +830,13 @@ 830 830 When downloading the images, choose the required image file for download. 831 831 832 832 833 -= 7. Order Info =907 += 8. Order Info = 834 834 835 835 836 836 [[image:image-20230131153105-4.png]] 837 837 838 838 839 -= 8. Packing Info =913 += 9. Packing Info = 840 840 841 841 842 842 (% style="color:#037691" %)**Package Includes**: ... ... @@ -850,7 +850,7 @@ 850 850 * Package Size / pcs : cm 851 851 * Weight / pcs : g 852 852 853 -= 9. Support =927 += 10. Support = 854 854 855 855 856 856 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- image-20230225154759-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -468.9 KB - Content