Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Bei - Content
-
... ... @@ -136,8 +136,11 @@ 136 136 * Measuring Range: Measure range can be customized, up to 100m. 137 137 * Accuracy: 0.2% F.S 138 138 * Long-Term Stability: ±0.2% F.S / Year 139 +* Overload 200% F.S 140 +* Zero Temperature Drift: ±2% F.S) 141 +* FS Temperature Drift: ±2% F.S 139 139 * Storage temperature: -30℃~~80℃ 140 -* Operating temperature: 0℃~~5 0℃143 +* Operating temperature: -40℃~~85℃ 141 141 * Material: 316 stainless steels 142 142 143 143 ... ... @@ -394,6 +394,9 @@ 394 394 [[image:1675144608950-310.png]] 395 395 396 396 400 +=== === 401 + 402 + 397 397 === 2.3.3 Battery Info === 398 398 399 399 ... ... @@ -418,6 +418,8 @@ 418 418 |PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 419 419 |PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure 420 420 427 + 428 + 421 421 The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value. 422 422 423 423 ... ... @@ -424,7 +424,7 @@ 424 424 === 2.3.5 0~~20mA value (IDC_IN) === 425 425 426 426 427 -The output value from **Pressure Probe**, use together with Probe Model to get the pressure value or water level.435 +The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level. 428 428 429 429 (% style="color:#037691" %)**Example**: 430 430 ... ... @@ -431,11 +431,6 @@ 431 431 27AE(H) = 10158 (D)/1000 = 10.158mA. 432 432 433 433 434 -Instead of pressure probe, User can also connect a general 4~~20mA in this port to support different types of 4~~20mA sensors. below is the connection example: 435 - 436 -[[image:image-20230225154759-1.png||height="408" width="741"]] 437 - 438 - 439 439 === 2.3.6 0~~30V value ( pin VDC_IN) === 440 440 441 441 ... ... @@ -468,7 +468,6 @@ 468 468 469 469 0x01: Interrupt Uplink Packet. 470 470 471 - 472 472 === (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 === 473 473 474 474 ... ... @@ -484,7 +484,7 @@ 484 484 485 485 Multiple sets of data collected are displayed in this form: 486 486 487 -[voltage value1], [voltage value2], [voltage value3],…[voltage value n /2]489 +[voltage value1], [voltage value2], [voltage value3],…[voltage value n] 488 488 489 489 490 490 === 2.3.9 Decode payload in The Things Network === ... ... @@ -567,18 +567,17 @@ 567 567 [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]] 568 568 569 569 570 -= 3. Configure PS-LB = 572 += 3. Configure PS-LB via AT Command or LoRaWAN Downlink = 571 571 572 -== 3.1 Configure Methods == 573 573 574 - PS-LB-NAsupports belowconfiguremethod:575 +Use can configure PS-LB via AT Command or LoRaWAN Downlink. 575 575 576 -* AT Command via Bluetooth Connection (**Recommand Way**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 577 -* AT Command via UART Connection : See [[FAQ>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/#H7.FAQ]]. 578 -* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 577 +* AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]]. 578 +* LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 579 579 580 +There are two kinds of commands to configure PS-LB, they are: 580 580 581 - ==3.2General Commands==582 +* (% style="color:#037691" %)**General Commands** 582 582 583 583 These commands are to configure: 584 584 ... ... @@ -585,18 +585,17 @@ 585 585 * General system settings like: uplink interval. 586 586 * LoRaWAN protocol & radio related command. 587 587 588 -They are same for all Dragino Device swhich support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:589 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 589 589 590 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>> url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]591 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 591 591 592 592 594 +* (% style="color:#037691" %)**Commands special design for PS-LB** 593 593 594 -== 3.3 Commands special design for PS-LB == 595 - 596 596 These commands only valid for PS-LB, as below: 597 597 598 598 599 -== =3.3.1 Set Transmit Interval Time ===599 +== 3.1 Set Transmit Interval Time == 600 600 601 601 602 602 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -625,7 +625,7 @@ 625 625 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 626 626 627 627 628 -== =3.3.2 Set Interrupt Mode ===628 +== 3.2 Set Interrupt Mode == 629 629 630 630 631 631 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -657,7 +657,7 @@ 657 657 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 658 658 659 659 660 -== =3.3.3Set the output time ===660 +== 3.3 Set the output time == 661 661 662 662 663 663 Feature, Control the output 3V3 , 5V or 12V. ... ... @@ -727,7 +727,7 @@ 727 727 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 728 728 729 729 730 -== =3.3.4 Set the Probe Model ===730 +== 3.4 Set the Probe Model == 731 731 732 732 733 733 Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value. ... ... @@ -757,6 +757,8 @@ 757 757 |AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK 758 758 |AT +PROBE =0000|Initial state, no settings.|OK 759 759 760 + 761 + 760 760 **Downlink Command: 0x08** 761 761 762 762 Format: Command Code (0x08) followed by 2 bytes. ... ... @@ -765,7 +765,7 @@ 765 765 * Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 766 766 767 767 768 -== =3.3.5=770 +== 3.5 Multiple collections are one uplink(Since firmware V1.1) == 769 769 770 770 771 771 Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. ... ... @@ -799,6 +799,8 @@ 799 799 OK 800 800 ))) 801 801 804 + 805 + 802 802 (% style="color:blue" %)**Downlink Command: 0xAE** 803 803 804 804 Format: Command Code (0x08) followed by 5 bytes. ... ... @@ -806,34 +806,107 @@ 806 806 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 807 807 808 808 809 -= 4. Battery & PowerConsumption=813 += 4. Battery & how to replace = 810 810 811 - PS-LB-NAuses ER26500 + SPC1520batterypack. See below link for detail information about the batteryinfo and how to replace.815 +== 4.1 Battery Type == 812 812 813 - [[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 814 814 818 +PS-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 815 815 816 - =5.OTAfirmwareupdate=820 +The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 817 817 822 +[[image:1675146710956-626.png]] 818 818 824 + 825 +Minimum Working Voltage for the PS-LB: 826 + 827 +PS-LB: 2.45v ~~ 3.6v 828 + 829 + 830 +== 4.2 Replace Battery == 831 + 832 + 833 +Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 834 + 835 +And make sure the positive and negative pins match. 836 + 837 + 838 +== 4.3 Power Consumption Analyze == 839 + 840 + 841 +Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 842 + 843 +Instruction to use as below: 844 + 845 +(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]] 846 + 847 +(% style="color:blue" %)**Step 2:**(%%) Open it and choose 848 + 849 +* Product Model 850 +* Uplink Interval 851 +* Working Mode 852 + 853 +And the Life expectation in difference case will be shown on the right. 854 + 855 +[[image:1675146895108-304.png]] 856 + 857 + 858 +The battery related documents as below: 859 + 860 +* [[Battery Dimension>>https://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]], 861 +* [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]] 862 +* [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]] 863 + 864 +[[image:image-20230131145708-3.png]] 865 + 866 + 867 +=== 4.3.1 Battery Note === 868 + 869 + 870 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 871 + 872 + 873 +=== 4.3.2 Replace the battery === 874 + 875 + 876 +You can change the battery in the PS-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 877 + 878 +The default battery pack of PS-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 879 + 880 + 881 += 5. Remote Configure device = 882 + 883 +== 5.1 Connect via BLE == 884 + 885 + 886 +Please see this instruction for how to configure via BLE: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]] 887 + 888 + 889 +== 5.2 AT Command Set == 890 + 891 + 892 + 893 += 6. OTA firmware update = 894 + 895 + 819 819 Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 820 820 821 821 822 -= 6. FAQ =899 += 7. FAQ = 823 823 824 -== 6.1 How to use AT Commandvia UARTto access device? ==901 +== 7.1 How to use AT Command to access device? == 825 825 826 826 827 827 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 828 828 829 829 830 -== 6.2 How to update firmware via UART port? ==907 +== 7.2 How to update firmware via UART port? == 831 831 832 832 833 833 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 834 834 835 835 836 -== 6.3 How to change the LoRa Frequency Bands/Region? ==913 +== 7.3 How to change the LoRa Frequency Bands/Region? == 837 837 838 838 839 839 You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]. ... ... @@ -840,13 +840,13 @@ 840 840 When downloading the images, choose the required image file for download. 841 841 842 842 843 -= 7. Order Info =920 += 8. Order Info = 844 844 845 845 846 846 [[image:image-20230131153105-4.png]] 847 847 848 848 849 -= 8. Packing Info =926 += 9. Packing Info = 850 850 851 851 852 852 (% style="color:#037691" %)**Package Includes**: ... ... @@ -861,7 +861,7 @@ 861 861 * Weight / pcs : g 862 862 863 863 864 -= 9. Support =941 += 10. Support = 865 865 866 866 867 867 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- image-20230225154759-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -468.9 KB - Content