Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/27 10:31
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -58,9 +58,7 @@ 58 58 * Uplink on periodically 59 59 * Downlink to change configure 60 60 * 8500mAh Battery for long term use 61 -* Controllable 3.3v,5v and 12v output to power external sensor 62 62 63 - 64 64 == 1.3 Specification == 65 65 66 66 ... ... @@ -107,7 +107,6 @@ 107 107 * Sleep Mode: 5uA @ 3.3v 108 108 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 109 109 110 - 111 111 == 1.4 Probe Types == 112 112 113 113 === 1.4.1 Thread Installation Type === ... ... @@ -126,7 +126,6 @@ 126 126 * Operating temperature: -20℃~~60℃ 127 127 * Connector Type: Various Types, see order info 128 128 129 - 130 130 === 1.4.2 Immersion Type === 131 131 132 132 ... ... @@ -136,11 +136,13 @@ 136 136 * Measuring Range: Measure range can be customized, up to 100m. 137 137 * Accuracy: 0.2% F.S 138 138 * Long-Term Stability: ±0.2% F.S / Year 135 +* Overload 200% F.S 136 +* Zero Temperature Drift: ±2% F.S) 137 +* FS Temperature Drift: ±2% F.S 139 139 * Storage temperature: -30℃~~80℃ 140 -* Operating temperature: 0℃~~5 0℃139 +* Operating temperature: -40℃~~85℃ 141 141 * Material: 316 stainless steels 142 142 143 - 144 144 == 1.5 Probe Dimension == 145 145 146 146 ... ... @@ -211,7 +211,6 @@ 211 211 ))) 212 212 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 213 213 214 - 215 215 == 1.9 Pin Mapping == 216 216 217 217 ... ... @@ -306,8 +306,18 @@ 306 306 After join success, it will start to upload messages to TTN and you can see the messages in the panel. 307 307 308 308 306 + 309 309 == 2.3 Uplink Payload == 310 310 309 + 310 +Uplink payloads have two types: 311 + 312 +* Distance Value: Use FPORT=2 313 +* Other control commands: Use other FPORT fields. 314 + 315 +The application server should parse the correct value based on FPORT settings. 316 + 317 + 311 311 === 2.3.1 Device Status, FPORT~=5 === 312 312 313 313 ... ... @@ -389,14 +389,28 @@ 389 389 |(% style="width:97px" %)((( 390 390 **Size(bytes)** 391 391 )))|(% style="width:48px" %)**2**|(% style="width:71px" %)**2**|(% style="width:98px" %)**2**|(% style="width:73px" %)**2**|(% style="width:122px" %)**1** 392 -|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3. 4BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.5ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.607E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.707E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.8IN126IN226INTpin"]]399 +|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.7IN126IN226INTpin"]] 393 393 394 394 [[image:1675144608950-310.png]] 395 395 396 396 397 -=== 2.3.3 BatteryInfo===404 +=== 2.3.3 Sensor value, FPORT~=7 === 398 398 399 399 407 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %) 408 +|(% style="width:94px" %)((( 409 +**Size(bytes)** 410 +)))|(% style="width:43px" %)2|(% style="width:367px" %)n 411 +|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:367px" %)((( 412 +Voltage value, each 2 bytes is a set of voltage values. 413 +))) 414 + 415 +[[image:image-20230220171300-1.png||height="207" width="863"]] 416 + 417 + 418 +=== 2.3.4 Battery Info === 419 + 420 + 400 400 Check the battery voltage for PS-LB. 401 401 402 402 Ex1: 0x0B45 = 2885mV ... ... @@ -404,27 +404,26 @@ 404 404 Ex2: 0x0B49 = 2889mV 405 405 406 406 407 -=== 2.3. 4Probe Model ===428 +=== 2.3.5 Probe Model === 408 408 409 409 410 -PS-LB has different kind of probe, 4~~20mA represent the full scale of the measuring range. So a 12mA output means different meaning for different probe.431 +PS-LB has different kind of probe, 0~~20mA represent the full scale of the measuring range. So a 15mA output means different meaning for different probe. 411 411 412 412 413 413 For example. 414 414 415 415 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 416 -|**Part Number**|**Probe Used**|**4~~20mA scale**|**Example: 12mA meaning** 417 -|PS-LB-I3|immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water 418 -|PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 419 -|PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure 437 +|(% style="width:111px" %)**Part Number**|(% style="width:158px" %)**Probe Used**|**0~~20mA scale**|**Example: 10mA meaning** 438 +|(% style="width:111px" %)PS-LB-I3|(% style="width:158px" %)immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water 439 +|(% style="width:111px" %)PS-LB-I5|(% style="width:158px" %)immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 420 420 421 -The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value.441 +The probe model field provides the convenient for server to identical how it should parse the 0~~20mA sensor value and get the correct value. 422 422 423 423 424 -=== 2.3. 50~~20mA value (IDC_IN) ===444 +=== 2.3.6 0~~20mA value (IDC_IN) === 425 425 426 426 427 -The output value from **Pressure Probe**, use together with Probe Model to get the pressure value or water level.447 +The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level. 428 428 429 429 (% style="color:#037691" %)**Example**: 430 430 ... ... @@ -431,14 +431,9 @@ 431 431 27AE(H) = 10158 (D)/1000 = 10.158mA. 432 432 433 433 434 - Insteadofpressure probe, User can also connect a general 4~~20mAin this port to support differenttypesof 4~~20mA sensors. belowis the connectionexample:454 +=== 2.3.7 0~~30V value ( pin VDC_IN) === 435 435 436 -[[image:image-20230225154759-1.png||height="408" width="741"]] 437 437 438 - 439 -=== 2.3.6 0~~30V value ( pin VDC_IN) === 440 - 441 - 442 442 Measure the voltage value. The range is 0 to 30V. 443 443 444 444 (% style="color:#037691" %)**Example**: ... ... @@ -446,7 +446,7 @@ 446 446 138E(H) = 5006(D)/1000= 5.006V 447 447 448 448 449 -=== 2.3. 7IN1&IN2&INT pin ===464 +=== 2.3.8 IN1&IN2&INT pin === 450 450 451 451 452 452 IN1 and IN2 are used as digital input pins. ... ... @@ -469,24 +469,6 @@ 469 469 0x01: Interrupt Uplink Packet. 470 470 471 471 472 -=== (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 === 473 - 474 - 475 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %) 476 -|(% style="width:94px" %)((( 477 -**Size(bytes)** 478 -)))|(% style="width:43px" %)2|(% style="width:367px" %)n 479 -|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)((( 480 -Voltage value, each 2 bytes is a set of voltage values. 481 -))) 482 - 483 -[[image:image-20230220171300-1.png||height="207" width="863"]] 484 - 485 -Multiple sets of data collected are displayed in this form: 486 - 487 -[voltage value1], [voltage value2], [voltage value3],…[voltage value n/2] 488 - 489 - 490 490 === 2.3.9 Decode payload in The Things Network === 491 491 492 492 ... ... @@ -567,36 +567,35 @@ 567 567 [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]] 568 568 569 569 570 -= 3. Configure PS-LB = 571 571 572 -= =3.1ConfigureMethods==568 += 3. Configure PS-LB via AT Command or LoRaWAN Downlink = 573 573 574 -PS-LB-NA supports below configure method: 575 575 576 -* AT Command via Bluetooth Connection (**Recommand Way**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 577 -* AT Command via UART Connection : See [[FAQ>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/#H7.FAQ]]. 578 -* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 571 +Use can configure PS-LB via AT Command or LoRaWAN Downlink. 579 579 573 +* AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]]. 574 +* LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 580 580 581 - == 3.2 GeneralCommands==576 +There are two kinds of commands to configure PS-LB, they are: 582 582 578 +* (% style="color:#037691" %)**General Commands** 579 + 583 583 These commands are to configure: 584 584 585 585 * General system settings like: uplink interval. 586 586 * LoRaWAN protocol & radio related command. 587 587 588 -They are same for all Dragino Device swhich support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:585 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 589 589 590 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>> url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]587 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 591 591 592 592 590 +* (% style="color:#037691" %)**Commands special design for PS-LB** 593 593 594 -== 3.3 Commands special design for PS-LB == 595 - 596 596 These commands only valid for PS-LB, as below: 597 597 598 598 599 -== =3.3.1 Set Transmit Interval Time ===595 +== 3.1 Set Transmit Interval Time == 600 600 601 601 602 602 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -624,10 +624,9 @@ 624 624 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 625 625 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 626 626 623 +== 3.2 Set Interrupt Mode == 627 627 628 -=== 3.3.2 Set Interrupt Mode === 629 629 630 - 631 631 Feature, Set Interrupt mode for GPIO_EXIT. 632 632 633 633 (% style="color:blue" %)**AT Command: AT+INTMOD** ... ... @@ -637,14 +637,14 @@ 637 637 |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 638 638 0 639 639 OK 640 -the mode is 0 = DisableInterrupt635 +the mode is 0 = No interruption 641 641 ))) 642 642 |(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 643 643 Set Transmit Interval 644 - 0. (Disable Interrupt),645 - ~1. (Trigger by rising and falling edge)646 - 2. (Trigger by falling edge)647 - 3. (Trigger by rising edge)639 +~1. (Disable Interrupt), 640 +2. (Trigger by rising and falling edge) 641 +3. (Trigger by falling edge) 642 +4. (Trigger by rising edge) 648 648 )))|(% style="width:157px" %)OK 649 649 650 650 (% style="color:blue" %)**Downlink Command: 0x06** ... ... @@ -656,10 +656,9 @@ 656 656 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 657 657 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 658 658 654 +== 3.3 Set the output time == 659 659 660 -=== 3.3.3 Set the output time === 661 661 662 - 663 663 Feature, Control the output 3V3 , 5V or 12V. 664 664 665 665 (% style="color:blue" %)**AT Command: AT+3V3T** ... ... @@ -726,114 +726,163 @@ 726 726 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 727 727 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 728 728 723 +== 3.4 Set the Probe Model == 729 729 730 -=== 3.3.4 Set the Probe Model === 731 731 726 +(% style="color:blue" %)**AT Command: AT** **+PROBE** 732 732 733 -Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value. 728 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:448px" %) 729 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 204px;" %)**Function**|=(% style="width: 85px;" %)**Response** 730 +|(% style="width:154px" %)AT +PROBE =?|(% style="width:204px" %)Get or Set the probe model.|(% style="width:85px" %)((( 731 +0 732 +OK 733 +))) 734 +|(% style="width:154px" %)AT +PROBE =0003|(% style="width:204px" %)Set water depth sensor mode, 3m type.|(% style="width:85px" %)OK 735 +|(% style="width:154px" %)AT +PROBE =0101|(% style="width:204px" %)Set pressure transmitters mode, first type.|(% style="width:85px" %)((( 736 +OK 737 +))) 738 +|(% style="width:154px" %)AT +PROBE =0000|(% style="width:204px" %)Initial state, no settings.|(% style="width:85px" %)((( 739 +OK 740 +))) 734 734 735 -** ATCommand:AT****+PROBE**742 +(% style="color:blue" %)**Downlink Command: 0x08** 736 736 737 - AT+PROBE=aabb744 +Format: Command Code (0x08) followed by 2 bytes. 738 738 739 -When aa=00, it is the water depth mode, and the current is converted into the water depth value; bb is the probe at a depth of several meters. 746 +* Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 747 +* Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 740 740 741 - When aa=01,its thepressuremode, which convertsthe currentintoapressurevalue;749 +== 3.5 Multiple collections are one uplink(Since firmware V1.1) == 742 742 743 -bb represents which type of pressure sensor it is. 744 744 745 - (A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C)752 +Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. 746 746 754 +(% style="color:blue" %)**AT Command: AT** **+STDC** 755 + 747 747 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 748 -|**Command Example**|**Function**|**Response** 749 -|AT +PROBE =?|Get or Set the probe model.|0 757 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response** 758 +|(% style="width:156px" %)AT+STDC=?|(% style="width:137px" %)((( 759 +Get the mode of multiple acquisitions and one uplink 760 +)))|((( 761 +1,10,18 750 750 OK 751 -|AT +PROBE =0003|Set water depth sensor mode, 3m type.|OK 752 -|((( 753 -AT +PROBE =000A 763 +))) 764 +|(% style="width:156px" %)AT+STDC=1,10,18|(% style="width:137px" %)Set the mode of multiple acquisitions and one uplink|((( 765 +OK 766 +**(% style="color:#037691" %)aa:**(%%) 767 +**0** means disable this function and use TDC to send packets. 768 +**1** means enable this function, use the method of multiple acquisitions to send packets. 769 +**(% style="color:#037691" %)bb:**(%%) Each collection interval (s), the value is 1~~65535 770 +**(% style="color:#037691" %)cc:**(%%)the number of collection times, the value is 1~~120 771 +))) 754 754 755 - 756 -)))|Set water depth sensor mode, 10m type.|OK 757 -|AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK 758 -|AT +PROBE =0000|Initial state, no settings.|OK 773 +(% style="color:blue" %)**Downlink Command: 0xAE** 759 759 760 - **DownlinkCommand:0x08**775 +Format: Command Code (0x08) followed by 5 bytes. 761 761 762 - Format:CommandCode(0x08)followed by2bytes.777 +* Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 763 763 764 -* Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 765 -* Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 779 += 4. Battery & how to replace = 766 766 781 +== 4.1 Battery Type == 767 767 768 -=== 3.3.5 Multiple collections are one uplink(Since firmware V1.1) === 769 769 784 +PS-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 770 770 771 - AddedAT+STDCcommandto collectthevoltage ofVDC_INPUTmultiple timesanduploadit at onetime.786 +The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 772 772 773 - (% style="color:blue" %)**AT Command:AT** **+STDC**788 +[[image:1675146710956-626.png]] 774 774 775 -AT+STDC=aa,bb,bb 776 776 777 -(% style="color:#037691" %)**aa:**(%%) 778 -**0:** means disable this function and use TDC to send packets. 779 -**1:** means enable this function, use the method of multiple acquisitions to send packets. 780 -(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535 781 -(% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120 791 +Minimum Working Voltage for the PS-LB: 782 782 783 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 784 -|**Command Example**|**Function**|**Response** 785 -|AT+STDC=?|Get the mode of multiple acquisitions and one uplink.|1,10,18 786 -OK 787 -|AT+STDC=1,10,18|Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|((( 788 -Attention:Take effect after ATZ 793 +PS-LB: 2.45v ~~ 3.6v 789 789 790 -OK 791 -))) 792 -|AT+STDC=0, 0,0|((( 793 -Use the TDC interval to send packets.(default) 794 794 795 - 796 -)))|((( 797 -Attention:Take effect after ATZ 796 +== 4.2 Replace Battery == 798 798 799 -OK 800 -))) 801 801 802 - (%style="color:blue"%)**DownlinkCommand:0xAE**799 +Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 803 803 804 - Format:CommandCode(0x08)followedby 5 bytes.801 +And make sure the positive and negative pins match. 805 805 806 -* Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 807 807 804 +== 4.3 Power Consumption Analyze == 808 808 809 -= 4. Battery & Power Consumption = 810 810 811 - PS-LB-NAusesER26500+SPC1520batterypack.Seebelowlinkfordetail informationabout the battery infoand how to replace.807 +Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 812 812 813 - [[**BatteryInfo & Power ConsumptionAnalyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .809 +Instruction to use as below: 814 814 811 +(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]] 815 815 816 -= 5.OTAfirmwareupdate=813 +(% style="color:blue" %)**Step 2:**(%%) Open it and choose 817 817 815 +* Product Model 816 +* Uplink Interval 817 +* Working Mode 818 818 819 +And the Life expectation in difference case will be shown on the right. 820 + 821 +[[image:1675146895108-304.png]] 822 + 823 + 824 +The battery related documents as below: 825 + 826 +* [[Battery Dimension>>https://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]], 827 +* [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]] 828 +* [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]] 829 + 830 +[[image:image-20230131145708-3.png]] 831 + 832 + 833 +=== 4.3.1 Battery Note === 834 + 835 + 836 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 837 + 838 + 839 +=== 4.3.2 Replace the battery === 840 + 841 + 842 +You can change the battery in the PS-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 843 + 844 +The default battery pack of PS-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 845 + 846 + 847 += 5. Remote Configure device = 848 + 849 +== 5.1 Connect via BLE == 850 + 851 + 852 +Please see this instruction for how to configure via BLE: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]] 853 + 854 + 855 +== 5.2 AT Command Set == 856 + 857 + 858 + 859 += 6. OTA firmware update = 860 + 861 + 819 819 Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 820 820 821 821 822 -= 6. FAQ =865 += 7. FAQ = 823 823 824 -== 6.1 How to use AT Commandvia UARTto access device? ==867 +== 7.1 How to use AT Command to access device? == 825 825 826 826 827 827 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 828 828 829 829 830 -== 6.2 How to update firmware via UART port? ==873 +== 7.2 How to update firmware via UART port? == 831 831 832 832 833 833 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 834 834 835 835 836 -== 6.3 How to change the LoRa Frequency Bands/Region? ==879 +== 7.3 How to change the LoRa Frequency Bands/Region? == 837 837 838 838 839 839 You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]. ... ... @@ -840,13 +840,13 @@ 840 840 When downloading the images, choose the required image file for download. 841 841 842 842 843 -= 7. Order Info =886 += 8. Order Info = 844 844 845 845 846 846 [[image:image-20230131153105-4.png]] 847 847 848 848 849 -= 8. Packing Info =892 += 9. Packing Info = 850 850 851 851 852 852 (% style="color:#037691" %)**Package Includes**: ... ... @@ -860,10 +860,9 @@ 860 860 * Package Size / pcs : cm 861 861 * Weight / pcs : g 862 862 906 += 10. Support = 863 863 864 -= 9. Support = 865 865 866 - 867 867 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 868 868 869 869 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
- image-20230222174559-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.4 KB - Content
- image-20230225154759-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -468.9 KB - Content