... ... @@ -139,8 +139,11 @@
139 139  * Measuring Range: Measure range can be customized, up to 100m.
140 140  * Accuracy: 0.2% F.S
141 141  * Long-Term Stability: ±0.2% F.S / Year
142 +* Overload 200% F.S
143 +* Zero Temperature Drift: ±2% F.S)
144 +* FS Temperature Drift: ±2% F.S
142 142  * Storage temperature: -30℃~~80℃
143 -* Operating temperature: 0℃~~50
146 +* Operating temperature: -40℃~~85℃
144 144  * Material: 316 stainless steels
145 145  
146 146  
... ... @@ -902,7 +902,7 @@
902 902  
903 903  = 7. FAQ =
904 904  
905 -== 7.1 How to use AT Command via UART to access device? ==
908 +== 7.1 How to use AT Command to access device? ==
906 906  
907 907  
908 908  See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]