Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/03 14:00
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Edwin - Content
-
... ... @@ -567,17 +567,18 @@ 567 567 [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]] 568 568 569 569 570 -= 3. Configure PS-LB via AT Command or LoRaWAN Downlink=570 += 3. Configure PS-LB = 571 571 572 +== 3.1 Configure Methods == 572 572 573 - Use can configurePS-LBviaATCommand orLoRaWANDownlink.574 +PS-LB-NA supports below configure method: 574 574 575 -* AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]]. 576 -* LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 576 +* AT Command via Bluetooth Connection (**Recommand Way**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 577 +* AT Command via UART Connection : See [[FAQ>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/#H7.FAQ]]. 578 +* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 577 577 578 -There are two kinds of commands to configure PS-LB, they are: 579 579 580 - * (% style="color:#037691"%)**General Commands**581 +== 3.2 General Commands == 581 581 582 582 These commands are to configure: 583 583 ... ... @@ -584,17 +584,18 @@ 584 584 * General system settings like: uplink interval. 585 585 * LoRaWAN protocol & radio related command. 586 586 587 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 588 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 588 588 589 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 590 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 590 590 591 591 592 -* (% style="color:#037691" %)**Commands special design for PS-LB** 593 593 594 +== 3.3 Commands special design for PS-LB == 595 + 594 594 These commands only valid for PS-LB, as below: 595 595 596 596 597 -== 3.1 Set Transmit Interval Time == 599 +=== 3.3.1 Set Transmit Interval Time === 598 598 599 599 600 600 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -622,9 +622,10 @@ 622 622 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 623 623 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 624 624 625 -== 3.2 Set Interrupt Mode == 626 626 628 +=== 3.3.2 Set Interrupt Mode === 627 627 630 + 628 628 Feature, Set Interrupt mode for GPIO_EXIT. 629 629 630 630 (% style="color:blue" %)**AT Command: AT+INTMOD** ... ... @@ -654,7 +654,7 @@ 654 654 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 655 655 656 656 657 -== 3.3 Set the output time == 660 +=== 3.3.3 Set the output time === 658 658 659 659 660 660 Feature, Control the output 3V3 , 5V or 12V. ... ... @@ -724,7 +724,7 @@ 724 724 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 725 725 726 726 727 -== 3.4 Set the Probe Model == 730 +=== 3.3.4 Set the Probe Model === 728 728 729 729 730 730 Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value. ... ... @@ -762,7 +762,7 @@ 762 762 * Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 763 763 764 764 765 -== 3.5 768 +=== 3.3.5 Multiple collections are one uplink(Since firmware V1.1) === 766 766 767 767 768 768 Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. ... ... @@ -803,107 +803,34 @@ 803 803 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 804 804 805 805 806 -= 4. Battery & how toreplace=809 += 4. Battery & Power Consumption = 807 807 808 - ==4.1BatteryType==811 +PS-LB-NA uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 809 809 813 + [[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 810 810 811 -PS-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 812 812 813 - Thedischargecurveis not linearso can’t simply use percentage to showthe battery level.Below is the batteryperformance.816 += 5. OTA firmware update = 814 814 815 -[[image:1675146710956-626.png]] 816 816 817 - 818 -Minimum Working Voltage for the PS-LB: 819 - 820 -PS-LB: 2.45v ~~ 3.6v 821 - 822 - 823 -== 4.2 Replace Battery == 824 - 825 - 826 -Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 827 - 828 -And make sure the positive and negative pins match. 829 - 830 - 831 -== 4.3 Power Consumption Analyze == 832 - 833 - 834 -Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 835 - 836 -Instruction to use as below: 837 - 838 -(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]] 839 - 840 -(% style="color:blue" %)**Step 2:**(%%) Open it and choose 841 - 842 -* Product Model 843 -* Uplink Interval 844 -* Working Mode 845 - 846 -And the Life expectation in difference case will be shown on the right. 847 - 848 -[[image:1675146895108-304.png]] 849 - 850 - 851 -The battery related documents as below: 852 - 853 -* [[Battery Dimension>>https://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]], 854 -* [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]] 855 -* [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]] 856 - 857 -[[image:image-20230131145708-3.png]] 858 - 859 - 860 -=== 4.3.1 Battery Note === 861 - 862 - 863 -The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 864 - 865 - 866 -=== 4.3.2 Replace the battery === 867 - 868 - 869 -You can change the battery in the PS-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 870 - 871 -The default battery pack of PS-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 872 - 873 - 874 -= 5. Remote Configure device = 875 - 876 -== 5.1 Connect via BLE == 877 - 878 - 879 -Please see this instruction for how to configure via BLE: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]] 880 - 881 - 882 -== 5.2 AT Command Set == 883 - 884 - 885 - 886 -= 6. OTA firmware update = 887 - 888 - 889 889 Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 890 890 891 891 892 -= 7. FAQ =822 += 6. FAQ = 893 893 894 -== 7.1 How to use AT Command via UART to access device? ==824 +== 6.1 How to use AT Command via UART to access device? == 895 895 896 896 897 897 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 898 898 899 899 900 -== 7.2 How to update firmware via UART port? ==830 +== 6.2 How to update firmware via UART port? == 901 901 902 902 903 903 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 904 904 905 905 906 -== 7.3 How to change the LoRa Frequency Bands/Region? ==836 +== 6.3 How to change the LoRa Frequency Bands/Region? == 907 907 908 908 909 909 You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]. ... ... @@ -910,13 +910,13 @@ 910 910 When downloading the images, choose the required image file for download. 911 911 912 912 913 -= 8. Order Info =843 += 7. Order Info = 914 914 915 915 916 916 [[image:image-20230131153105-4.png]] 917 917 918 918 919 -= 9. Packing Info =849 += 8. Packing Info = 920 920 921 921 922 922 (% style="color:#037691" %)**Package Includes**: ... ... @@ -931,7 +931,7 @@ 931 931 * Weight / pcs : g 932 932 933 933 934 -= 10. Support =864 += 9. Support = 935 935 936 936 937 937 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.