... ... @@ -136,8 +136,11 @@ 136 136 * Measuring Range: Measure range can be customized, up to 100m. 137 137 * Accuracy: 0.2% F.S 138 138 * Long-Term Stability: ±0.2% F.S / Year 139 +* Overload 200% F.S 140 +* Zero Temperature Drift: ±2% F.S) 141 +* FS Temperature Drift: ±2% F.S 139 139 * Storage temperature: -30℃~~80℃ 140 -* Operating temperature: 0℃~~5 0℃143 +* Operating temperature: -40℃~~85℃ 141 141 * Material: 316 stainless steels 142 142 143 143 ... ... @@ -394,6 +394,9 @@ 394 394 [[image:1675144608950-310.png]] 395 395 396 396 400 +=== === 401 + 402 + 397 397 === 2.3.3 Battery Info === 398 398 399 399 ... ... @@ -418,6 +418,8 @@ 418 418 |PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 419 419 |PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure 420 420 427 + 428 + 421 421 The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value. 422 422 423 423 ... ... @@ -424,7 +424,7 @@ 424 424 === 2.3.5 0~~20mA value (IDC_IN) === 425 425 426 426 427 -The output value from **Pressure Probe**, use together with Probe Model to get the pressure value or water level.435 +The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level. 428 428 429 429 (% style="color:#037691" %)**Example**: 430 430 ... ... @@ -431,11 +431,6 @@ 431 431 27AE(H) = 10158 (D)/1000 = 10.158mA. 432 432 433 433 434 -Instead of pressure probe, User can also connect a general 4~~20mA in this port to support different types of 4~~20mA sensors. below is the connection example: 435 - 436 -[[image:image-20230225154759-1.png||height="408" width="741"]] 437 - 438 - 439 439 === 2.3.6 0~~30V value ( pin VDC_IN) === 440 440 441 441 ... ... @@ -468,7 +468,6 @@ 468 468 469 469 0x01: Interrupt Uplink Packet. 470 470 471 - 472 472 === (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 === 473 473 474 474 ... ... @@ -484,7 +484,7 @@ 484 484 485 485 Multiple sets of data collected are displayed in this form: 486 486 487 -[voltage value1], [voltage value2], [voltage value3],…[voltage value n /2]489 +[voltage value1], [voltage value2], [voltage value3],…[voltage value n] 488 488 489 489 490 490 === 2.3.9 Decode payload in The Things Network === ... ... @@ -622,6 +622,7 @@ 622 622 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 623 623 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 624 624 627 + 625 625 == 3.2 Set Interrupt Mode == 626 626 627 627 ... ... @@ -754,6 +754,8 @@ 754 754 |AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK 755 755 |AT +PROBE =0000|Initial state, no settings.|OK 756 756 760 + 761 + 757 757 **Downlink Command: 0x08** 758 758 759 759 Format: Command Code (0x08) followed by 2 bytes. ... ... @@ -796,6 +796,8 @@ 796 796 OK 797 797 ))) 798 798 804 + 805 + 799 799 (% style="color:blue" %)**Downlink Command: 0xAE** 800 800 801 801 Format: Command Code (0x08) followed by 5 bytes. ... ... @@ -891,7 +891,7 @@ 891 891 892 892 = 7. FAQ = 893 893 894 -== 7.1 How to use AT Command via UARTto access device? ==901 +== 7.1 How to use AT Command to access device? == 895 895 896 896 897 897 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]
- image-20230225154759-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -468.9 KB - Content