... ... @@ -139,8 +139,11 @@
139 139  * Measuring Range: Measure range can be customized, up to 100m.
140 140  * Accuracy: 0.2% F.S
141 141  * Long-Term Stability: ±0.2% F.S / Year
142 +* Overload 200% F.S
143 +* Zero Temperature Drift: ±2% F.S)
144 +* FS Temperature Drift: ±2% F.S
142 142  * Storage temperature: -30℃~~80℃
143 -* Operating temperature: 0℃~~50
146 +* Operating temperature: -40℃~~85℃
144 144  * Material: 316 stainless steels
145 145  
146 146  
... ... @@ -627,6 +627,8 @@
627 627  * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
628 628  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds