Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/27 10:31
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Bei - Content
-
... ... @@ -60,7 +60,6 @@ 60 60 * 8500mAh Battery for long term use 61 61 * Controllable 3.3v,5v and 12v output to power external sensor 62 62 63 - 64 64 == 1.3 Specification == 65 65 66 66 ... ... @@ -107,7 +107,6 @@ 107 107 * Sleep Mode: 5uA @ 3.3v 108 108 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 109 109 110 - 111 111 == 1.4 Probe Types == 112 112 113 113 === 1.4.1 Thread Installation Type === ... ... @@ -126,7 +126,6 @@ 126 126 * Operating temperature: -20℃~~60℃ 127 127 * Connector Type: Various Types, see order info 128 128 129 - 130 130 === 1.4.2 Immersion Type === 131 131 132 132 ... ... @@ -136,11 +136,13 @@ 136 136 * Measuring Range: Measure range can be customized, up to 100m. 137 137 * Accuracy: 0.2% F.S 138 138 * Long-Term Stability: ±0.2% F.S / Year 136 +* Overload 200% F.S 137 +* Zero Temperature Drift: ±2% F.S) 138 +* FS Temperature Drift: ±2% F.S 139 139 * Storage temperature: -30℃~~80℃ 140 -* Operating temperature: 0℃~~5 0℃140 +* Operating temperature: -40℃~~85℃ 141 141 * Material: 316 stainless steels 142 142 143 - 144 144 == 1.5 Probe Dimension == 145 145 146 146 ... ... @@ -211,7 +211,6 @@ 211 211 ))) 212 212 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 213 213 214 - 215 215 == 1.9 Pin Mapping == 216 216 217 217 ... ... @@ -394,6 +394,9 @@ 394 394 [[image:1675144608950-310.png]] 395 395 396 396 395 +=== === 396 + 397 + 397 397 === 2.3.3 Battery Info === 398 398 399 399 ... ... @@ -418,6 +418,7 @@ 418 418 |PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 419 419 |PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure 420 420 422 + 421 421 The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value. 422 422 423 423 ... ... @@ -424,7 +424,7 @@ 424 424 === 2.3.5 0~~20mA value (IDC_IN) === 425 425 426 426 427 -The output value from **Pressure Probe**, use together with Probe Model to get the pressure value or water level.429 +The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level. 428 428 429 429 (% style="color:#037691" %)**Example**: 430 430 ... ... @@ -431,11 +431,6 @@ 431 431 27AE(H) = 10158 (D)/1000 = 10.158mA. 432 432 433 433 434 -Instead of pressure probe, User can also connect a general 4~~20mA in this port to support different types of 4~~20mA sensors. below is the connection example: 435 - 436 -[[image:image-20230225154759-1.png||height="408" width="741"]] 437 - 438 - 439 439 === 2.3.6 0~~30V value ( pin VDC_IN) === 440 440 441 441 ... ... @@ -468,7 +468,6 @@ 468 468 469 469 0x01: Interrupt Uplink Packet. 470 470 471 - 472 472 === (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 === 473 473 474 474 ... ... @@ -622,7 +622,6 @@ 622 622 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 623 623 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 624 624 625 - 626 626 == 3.2 Set Interrupt Mode == 627 627 628 628 ... ... @@ -654,7 +654,6 @@ 654 654 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 655 655 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 656 656 657 - 658 658 == 3.3 Set the output time == 659 659 660 660 ... ... @@ -724,7 +724,6 @@ 724 724 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 725 725 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 726 726 727 - 728 728 == 3.4 Set the Probe Model == 729 729 730 730 ... ... @@ -755,6 +755,7 @@ 755 755 |AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK 756 756 |AT +PROBE =0000|Initial state, no settings.|OK 757 757 751 + 758 758 **Downlink Command: 0x08** 759 759 760 760 Format: Command Code (0x08) followed by 2 bytes. ... ... @@ -762,7 +762,6 @@ 762 762 * Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 763 763 * Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 764 764 765 - 766 766 == 3.5 Multiple collections are one uplink(Since firmware V1.1) == 767 767 768 768 ... ... @@ -797,6 +797,7 @@ 797 797 OK 798 798 ))) 799 799 793 + 800 800 (% style="color:blue" %)**Downlink Command: 0xAE** 801 801 802 802 Format: Command Code (0x08) followed by 5 bytes. ... ... @@ -803,7 +803,6 @@ 803 803 804 804 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 805 805 806 - 807 807 = 4. Battery & how to replace = 808 808 809 809 == 4.1 Battery Type == ... ... @@ -931,7 +931,6 @@ 931 931 * Package Size / pcs : cm 932 932 * Weight / pcs : g 933 933 934 - 935 935 = 10. Support = 936 936 937 937
- image-20230225154759-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -468.9 KB - Content