... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Bei
Content
... ... @@ -58,9 +58,9 @@
58 58  * Uplink on periodically
59 59  * Downlink to change configure
60 60  * 8500mAh Battery for long term use
61 -* Controllable 3.3v,5v and 12v output to power external sensor
62 62  
63 63  
63 +
64 64  == 1.3 Specification ==
65 65  
66 66  
... ... @@ -108,6 +108,7 @@
108 108  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
109 109  
110 110  
111 +
111 111  == 1.4 Probe Types ==
112 112  
113 113  === 1.4.1 Thread Installation Type ===
... ... @@ -127,6 +127,7 @@
127 127  * Connector Type: Various Types, see order info
128 128  
129 129  
131 +
130 130  === 1.4.2 Immersion Type ===
131 131  
132 132  
... ... @@ -136,11 +136,15 @@
136 136  * Measuring Range: Measure range can be customized, up to 100m.
137 137  * Accuracy: 0.2% F.S
138 138  * Long-Term Stability: ±0.2% F.S / Year
141 +* Overload 200% F.S
142 +* Zero Temperature Drift: ±2% F.S)
143 +* FS Temperature Drift: ±2% F.S
139 139  * Storage temperature: -30℃~~80℃
140 -* Operating temperature: 0℃~~50
145 +* Operating temperature: -40℃~~85℃
141 141  * Material: 316 stainless steels
142 142  
143 143  
149 +
144 144  == 1.5 Probe Dimension ==
145 145  
146 146  
... ... @@ -212,6 +212,7 @@
212 212  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.
213 213  
214 214  
221 +
215 215  == 1.9 Pin Mapping ==
216 216  
217 217  
... ... @@ -308,6 +308,15 @@
308 308  
309 309  == 2.3 ​Uplink Payload ==
310 310  
318 +
319 +Uplink payloads have two types:
320 +
321 +* Distance Value: Use FPORT=2
322 +* Other control commands: Use other FPORT fields.
323 +
324 +The application server should parse the correct value based on FPORT settings.
325 +
326 +
311 311  === 2.3.1 Device Status, FPORT~=5 ===
312 312  
313 313  
... ... @@ -394,9 +394,23 @@
394 394  [[image:1675144608950-310.png]]
395 395  
396 396  
397 -=== 2.3.3 Battery Info ===
413 +=== 2.3.3 Sensor value, FPORT~=7 ===
398 398  
399 399  
416 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
417 +|(% style="width:94px" %)(((
418 +**Size(bytes)**
419 +)))|(% style="width:43px" %)2|(% style="width:367px" %)n
420 +|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)(((
421 +Voltage value, each 2 bytes is a set of voltage values.
422 +)))
423 +
424 +[[image:image-20230220171300-1.png||height="207" width="863"]]
425 +
426 +
427 +=== 2.3.4 Battery Info ===
428 +
429 +
400 400  Check the battery voltage for PS-LB.
401 401  
402 402  Ex1: 0x0B45 = 2885mV
... ... @@ -404,27 +404,26 @@
404 404  Ex2: 0x0B49 = 2889mV
405 405  
406 406  
407 -=== 2.3.4 Probe Model ===
437 +=== 2.3.5 Probe Model ===
408 408  
409 409  
410 -PS-LB has different kind of probe, 4~~20mA represent the full scale of the measuring range. So a 12mA output means different meaning for different probe. 
440 +PS-LB has different kind of probe, 0~~20mA represent the full scale of the measuring range. So a 15mA output means different meaning for different probe. 
411 411  
412 412  
413 413  For example.
414 414  
415 415  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
416 -|**Part Number**|**Probe Used**|**4~~20mA scale**|**Example: 12mA meaning**
417 -|PS-LB-I3|immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
418 -|PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
419 -|PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure
446 +|(% style="width:111px" %)**Part Number**|(% style="width:158px" %)**Probe Used**|**0~~20mA scale**|**Example: 10mA meaning**
447 +|(% style="width:111px" %)PS-LB-I3|(% style="width:158px" %)immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
448 +|(% style="width:111px" %)PS-LB-I5|(% style="width:158px" %)immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
420 420  
421 -The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value.
450 +The probe model field provides the convenient for server to identical how it should parse the 0~~20mA sensor value and get the correct value.
422 422  
423 423  
424 -=== 2.3.5 0~~20mA value (IDC_IN) ===
453 +=== 2.3.6 0~~20mA value (IDC_IN) ===
425 425  
426 426  
427 -The output value from **Pressure Probe**, use together with Probe Model to get the pressure value or water level.
456 +The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level.
428 428  
429 429  (% style="color:#037691" %)**Example**:
430 430  
... ... @@ -431,14 +431,9 @@
431 431  27AE(H) = 10158 (D)/1000 = 10.158mA.
432 432  
433 433  
434 -Instead of pressure probe, User can also connect a general 4~~20mA in this port to support different types of 4~~20mA sensors. below is the connection example:
463 +=== 2.3.7 0~~30V value ( pin VDC_IN) ===
435 435  
436 -[[image:image-20230225154759-1.png||height="408" width="741"]]
437 437  
438 -
439 -=== 2.3.6 0~~30V value ( pin VDC_IN) ===
440 -
441 -
442 442  Measure the voltage value. The range is 0 to 30V.
443 443  
444 444  (% style="color:#037691" %)**Example**:
... ... @@ -446,7 +446,7 @@
446 446  138E(H) = 5006(D)/1000= 5.006V
447 447  
448 448  
449 -=== 2.3.7 IN1&IN2&INT pin ===
473 +=== 2.3.8 IN1&IN2&INT pin ===
450 450  
451 451  
452 452  IN1 and IN2 are used as digital input pins.
... ... @@ -469,24 +469,6 @@
469 469  0x01: Interrupt Uplink Packet.
470 470  
471 471  
472 -=== (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 ===
473 -
474 -
475 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
476 -|(% style="width:94px" %)(((
477 -**Size(bytes)**
478 -)))|(% style="width:43px" %)2|(% style="width:367px" %)n
479 -|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)(((
480 -Voltage value, each 2 bytes is a set of voltage values.
481 -)))
482 -
483 -[[image:image-20230220171300-1.png||height="207" width="863"]]
484 -
485 -Multiple sets of data collected are displayed in this form:
486 -
487 -[voltage value1], [voltage value2], [voltage value3],…[voltage value n/2]
488 -
489 -
490 490  === 2.3.9 ​Decode payload in The Things Network ===
491 491  
492 492  
... ... @@ -623,6 +623,7 @@
623 623  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
624 624  
625 625  
632 +
626 626  == 3.2 Set Interrupt Mode ==
627 627  
628 628  
... ... @@ -635,14 +635,14 @@
635 635  |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
636 636  0
637 637  OK
638 -the mode is 0 =Disable Interrupt
645 +the mode is 0 = No interruption
639 639  )))
640 640  |(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
641 641  Set Transmit Interval
642 -0. (Disable Interrupt),
643 -~1. (Trigger by rising and falling edge)
644 -2. (Trigger by falling edge)
645 -3. (Trigger by rising edge)
649 +~1. (Disable Interrupt),
650 +2. (Trigger by rising and falling edge)
651 +3. (Trigger by falling edge)
652 +4. (Trigger by rising edge)
646 646  )))|(% style="width:157px" %)OK
647 647  
648 648  (% style="color:blue" %)**Downlink Command: 0x06**
... ... @@ -655,6 +655,7 @@
655 655  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
656 656  
657 657  
665 +
658 658  == 3.3 Set the output time ==
659 659  
660 660  
... ... @@ -725,44 +725,35 @@
725 725  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
726 726  
727 727  
736 +
728 728  == 3.4 Set the Probe Model ==
729 729  
730 730  
731 -Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value.
740 +(% style="color:blue" %)**AT Command: AT** **+PROBE**
732 732  
733 -**AT Command: AT** **+PROBE**
734 -
735 -AT+PROBE=aabb
736 -
737 -When aa=00, it is the water depth mode, and the current is converted into the water depth value; bb is the probe at a depth of several meters.
738 -
739 -When aa=01, it is the pressure mode, which converts the current into a pressure value;
740 -
741 -bb represents which type of pressure sensor it is.
742 -
743 -(A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C)
744 -
745 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
746 -|**Command Example**|**Function**|**Response**
747 -|AT +PROBE =?|Get or Set the probe model.|0
742 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:448px" %)
743 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 204px;" %)**Function**|=(% style="width: 85px;" %)**Response**
744 +|(% style="width:154px" %)AT +PROBE =?|(% style="width:204px" %)Get or Set the probe model.|(% style="width:85px" %)(((
745 +0
748 748  OK
749 -|AT +PROBE =0003|Set water depth sensor mode, 3m type.|OK
750 -|(((
751 -AT +PROBE =000A
747 +)))
748 +|(% style="width:154px" %)AT +PROBE =0003|(% style="width:204px" %)Set water depth sensor mode, 3m type.|(% style="width:85px" %)OK
749 +|(% style="width:154px" %)AT +PROBE =0101|(% style="width:204px" %)Set pressure transmitters mode, first type.|(% style="width:85px" %)(((
750 +OK
751 +)))
752 +|(% style="width:154px" %)AT +PROBE =0000|(% style="width:204px" %)Initial state, no settings.|(% style="width:85px" %)(((
753 +OK
754 +)))
752 752  
753 -
754 -)))|Set water depth sensor mode, 10m type.|OK
755 -|AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK
756 -|AT +PROBE =0000|Initial state, no settings.|OK
756 +(% style="color:blue" %)**Downlink Command: 0x08**
757 757  
758 -**Downlink Command: 0x08**
759 -
760 760  Format: Command Code (0x08) followed by 2 bytes.
761 761  
762 -* Example 1: Downlink Payload: 080003  **~-~-->**  AT+PROBE=0003
763 -* Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
760 +* Example 1: Downlink Payload: 080003  **~-~-->**  AT+PROBE=0003
761 +* Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
764 764  
765 765  
764 +
766 766  == 3.5 Multiple collections are one uplink(Since firmware V1.1) ==
767 767  
768 768  
... ... @@ -770,31 +770,21 @@
770 770  
771 771  (% style="color:blue" %)**AT Command: AT** **+STDC**
772 772  
773 -AT+STDC=aa,bb,bb
774 -
775 -(% style="color:#037691" %)**aa:**(%%)
776 -**0:** means disable this function and use TDC to send packets.
777 -**1:** means enable this function, use the method of multiple acquisitions to send packets.
778 -(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
779 -(% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120
780 -
781 781  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
782 -|**Command Example**|**Function**|**Response**
783 -|AT+STDC=?|Get the mode of multiple acquisitions and one uplink.|1,10,18
773 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response**
774 +|(% style="width:156px" %)AT+STDC=?|(% style="width:137px" %)(((
775 +Get the mode of multiple acquisitions and one uplink
776 +)))|(((
777 +1,10,18
784 784  OK
785 -|AT+STDC=1,10,18|Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|(((
786 -Attention:Take effect after ATZ
787 -
788 -OK
789 789  )))
790 -|AT+STDC=0, 0,0|(((
791 -Use the TDC interval to send packets.(default)
792 -
793 -
794 -)))|(((
795 -Attention:Take effect after ATZ
796 -
780 +|(% style="width:156px" %)AT+STDC=1,10,18|(% style="width:137px" %)Set the mode of multiple acquisitions and one uplink|(((
797 797  OK
782 +(% style="color:#037691" %)**aa:**(%%)
783 +**0:** means disable this function and use TDC to send packets.
784 +**1:** means enable this function, use the method of multiple acquisitions to send packets.
785 +(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
786 +(% style="color:#037691" %)**cc: **(%%)the number of collection times, the value is 1~~120
798 798  )))
799 799  
800 800  (% style="color:blue" %)**Downlink Command: 0xAE**
... ... @@ -804,6 +804,7 @@
804 804  * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->**  AT+STDC=1,600,18
805 805  
806 806  
796 +
807 807  = 4. Battery & how to replace =
808 808  
809 809  == 4.1 Battery Type ==
... ... @@ -932,6 +932,7 @@
932 932  * Weight / pcs : g
933 933  
934 934  
925 +
935 935  = 10. Support =
936 936  
937 937  