<
From version < 50.2 >
edited by Xiaoling
on 2023/02/27 09:26
To version < 52.2 >
edited by Xiaoling
on 2023/03/24 13:55
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -139,11 +139,8 @@
139 139  * Measuring Range: Measure range can be customized, up to 100m.
140 140  * Accuracy: 0.2% F.S
141 141  * Long-Term Stability: ±0.2% F.S / Year
142 -* Overload 200% F.S
143 -* Zero Temperature Drift: ±2% F.S)
144 -* FS Temperature Drift: ±2% F.S
145 145  * Storage temperature: -30℃~~80℃
146 -* Operating temperature: -40℃~~85℃
143 +* Operating temperature: 0℃~~50
147 147  * Material: 316 stainless steels
148 148  
149 149  
... ... @@ -905,7 +905,7 @@
905 905  
906 906  = 7. FAQ =
907 907  
908 -== 7.1 How to use AT Command to access device? ==
905 +== 7.1 How to use AT Command via UART to access device? ==
909 909  
910 910  
911 911  See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0