... ... @@ -58,7 +58,6 @@
58 58  * Uplink on periodically
59 59  * Downlink to change configure
60 60  * 8500mAh Battery for long term use
61 -* Controllable 3.3v,5v and 12v output to power external sensor
62 62  
63 63  
64 64  
... ... @@ -316,6 +316,15 @@
316 316  
317 317  == 2.3 ​Uplink Payload ==
318 318  
318 +
319 +Uplink payloads have two types:
320 +
321 +* Distance Value: Use FPORT=2
322 +* Other control commands: Use other FPORT fields.
323 +
324 +The application server should parse the correct value based on FPORT settings.
325 +
326 +
319 319  === 2.3.1 Device Status, FPORT~=5 ===
320 320  
321 321  
... ... @@ -402,9 +402,23 @@
402 402  [[image:1675144608950-310.png]]
403 403  
404 404  
405 -=== 2.3.3 Battery Info ===
413 +=== 2.3.3 Sensor value, FPORT~=7 ===
406 406  
407 407  
416 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
417 +|(% style="width:94px" %)(((
418 +**Size(bytes)**
419 +)))|(% style="width:43px" %)2|(% style="width:367px" %)n
420 +|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)(((
421 +Voltage value, each 2 bytes is a set of voltage values.
422 +)))
423 +
424 +[[image:image-20230220171300-1.png||height="207" width="863"]]
425 +
426 +
427 +=== 2.3.4 Battery Info ===
428 +
429 +
408 408  Check the battery voltage for PS-LB.
409 409  
410 410  Ex1: 0x0B45 = 2885mV
... ... @@ -412,27 +412,26 @@
412 412  Ex2: 0x0B49 = 2889mV
413 413  
414 414  
415 -=== 2.3.4 Probe Model ===
437 +=== 2.3.5 Probe Model ===
416 416  
417 417  
418 -PS-LB has different kind of probe, 4~~20mA represent the full scale of the measuring range. So a 12mA output means different meaning for different probe. 
440 +PS-LB has different kind of probe, 0~~20mA represent the full scale of the measuring range. So a 15mA output means different meaning for different probe. 
419 419  
420 420  
421 421  For example.
422 422  
423 423  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
424 -|**Part Number**|**Probe Used**|**4~~20mA scale**|**Example: 12mA meaning**
425 -|PS-LB-I3|immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
426 -|PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
427 -|PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure
446 +|(% style="width:111px" %)**Part Number**|(% style="width:158px" %)**Probe Used**|**0~~20mA scale**|**Example: 10mA meaning**
447 +|(% style="width:111px" %)PS-LB-I3|(% style="width:158px" %)immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
448 +|(% style="width:111px" %)PS-LB-I5|(% style="width:158px" %)immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
428 428  
429 -The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value.
450 +The probe model field provides the convenient for server to identical how it should parse the 0~~20mA sensor value and get the correct value.
430 430  
431 431  
432 -=== 2.3.5 0~~20mA value (IDC_IN) ===
453 +=== 2.3.6 0~~20mA value (IDC_IN) ===
433 433  
434 434  
435 -The output value from **Pressure Probe**, use together with Probe Model to get the pressure value or water level.
456 +The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level.
436 436  
437 437  (% style="color:#037691" %)**Example**:
438 438  
... ... @@ -439,14 +439,9 @@
439 439  27AE(H) = 10158 (D)/1000 = 10.158mA.
440 440  
441 441  
442 -Instead of pressure probe, User can also connect a general 4~~20mA in this port to support different types of 4~~20mA sensors. below is the connection example:
463 +=== 2.3.7 0~~30V value ( pin VDC_IN) ===
443 443  
444 -[[image:image-20230225154759-1.png||height="408" width="741"]]
445 445  
446 -
447 -=== 2.3.6 0~~30V value ( pin VDC_IN) ===
448 -
449 -
450 450  Measure the voltage value. The range is 0 to 30V.
451 451  
452 452  (% style="color:#037691" %)**Example**:
... ... @@ -454,7 +454,7 @@
454 454  138E(H) = 5006(D)/1000= 5.006V
455 455  
456 456  
457 -=== 2.3.7 IN1&IN2&INT pin ===
473 +=== 2.3.8 IN1&IN2&INT pin ===
458 458  
459 459  
460 460  IN1 and IN2 are used as digital input pins.
... ... @@ -477,24 +477,6 @@
477 477  0x01: Interrupt Uplink Packet.
478 478  
479 479  
480 -=== (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 ===
481 -
482 -
483 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
484 -|(% style="width:94px" %)(((
485 -**Size(bytes)**
486 -)))|(% style="width:43px" %)2|(% style="width:367px" %)n
487 -|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)(((
488 -Voltage value, each 2 bytes is a set of voltage values.
489 -)))
490 -
491 -[[image:image-20230220171300-1.png||height="207" width="863"]]
492 -
493 -Multiple sets of data collected are displayed in this form:
494 -
495 -[voltage value1], [voltage value2], [voltage value3],…[voltage value n/2]
496 -
497 -
498 498  === 2.3.9 ​Decode payload in The Things Network ===
499 499  
500 500  
... ... @@ -644,14 +644,14 @@
644 644  |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
645 645  0
646 646  OK
647 -the mode is 0 =Disable Interrupt
645 +the mode is 0 = No interruption
648 648  )))
649 649  |(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
650 650  Set Transmit Interval
651 -0. (Disable Interrupt),
652 -~1. (Trigger by rising and falling edge)
653 -2. (Trigger by falling edge)
654 -3. (Trigger by rising edge)
649 +~1. (Disable Interrupt),
650 +2. (Trigger by rising and falling edge)
651 +3. (Trigger by falling edge)
652 +4. (Trigger by rising edge)
655 655  )))|(% style="width:157px" %)OK
656 656  
657 657  (% style="color:blue" %)**Downlink Command: 0x06**
... ... @@ -739,39 +739,28 @@
739 739  == 3.4 Set the Probe Model ==
740 740  
741 741  
742 -Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value.
740 +(% style="color:blue" %)**AT Command: AT** **+PROBE**
743 743  
744 -**AT Command: AT** **+PROBE**
745 -
746 -AT+PROBE=aabb
747 -
748 -When aa=00, it is the water depth mode, and the current is converted into the water depth value; bb is the probe at a depth of several meters.
749 -
750 -When aa=01, it is the pressure mode, which converts the current into a pressure value;
751 -
752 -bb represents which type of pressure sensor it is.
753 -
754 -(A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C)
755 -
756 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
757 -|**Command Example**|**Function**|**Response**
758 -|AT +PROBE =?|Get or Set the probe model.|0
742 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:448px" %)
743 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 204px;" %)**Function**|=(% style="width: 85px;" %)**Response**
744 +|(% style="width:154px" %)AT +PROBE =?|(% style="width:204px" %)Get or Set the probe model.|(% style="width:85px" %)(((
745 +0
759 759  OK
760 -|AT +PROBE =0003|Set water depth sensor mode, 3m type.|OK
761 -|(((
762 -AT +PROBE =000A
747 +)))
748 +|(% style="width:154px" %)AT +PROBE =0003|(% style="width:204px" %)Set water depth sensor mode, 3m type.|(% style="width:85px" %)OK
749 +|(% style="width:154px" %)AT +PROBE =0101|(% style="width:204px" %)Set pressure transmitters mode, first type.|(% style="width:85px" %)(((
750 +OK
751 +)))
752 +|(% style="width:154px" %)AT +PROBE =0000|(% style="width:204px" %)Initial state, no settings.|(% style="width:85px" %)(((
753 +OK
754 +)))
763 763  
764 -
765 -)))|Set water depth sensor mode, 10m type.|OK
766 -|AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK
767 -|AT +PROBE =0000|Initial state, no settings.|OK
756 +(% style="color:blue" %)**Downlink Command: 0x08**
768 768  
769 -**Downlink Command: 0x08**
770 -
771 771  Format: Command Code (0x08) followed by 2 bytes.
772 772  
773 -* Example 1: Downlink Payload: 080003  **~-~-->**  AT+PROBE=0003
774 -* Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
760 +* Example 1: Downlink Payload: 080003  **~-~-->**  AT+PROBE=0003
761 +* Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
775 775  
776 776  
777 777  
... ... @@ -782,31 +782,21 @@
782 782  
783 783  (% style="color:blue" %)**AT Command: AT** **+STDC**
784 784  
785 -AT+STDC=aa,bb,bb
786 -
787 -(% style="color:#037691" %)**aa:**(%%)
788 -**0:** means disable this function and use TDC to send packets.
789 -**1:** means enable this function, use the method of multiple acquisitions to send packets.
790 -(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
791 -(% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120
792 -
793 793  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
794 -|**Command Example**|**Function**|**Response**
795 -|AT+STDC=?|Get the mode of multiple acquisitions and one uplink.|1,10,18
773 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response**
774 +|(% style="width:156px" %)AT+STDC=?|(% style="width:137px" %)(((
775 +Get the mode of multiple acquisitions and one uplink
776 +)))|(((
777 +1,10,18
796 796  OK
797 -|AT+STDC=1,10,18|Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|(((
798 -Attention:Take effect after ATZ
799 -
800 -OK
801 801  )))
802 -|AT+STDC=0, 0,0|(((
803 -Use the TDC interval to send packets.(default)
804 -
805 -
806 -)))|(((
807 -Attention:Take effect after ATZ
808 -
780 +|(% style="width:156px" %)AT+STDC=1,10,18|(% style="width:137px" %)Set the mode of multiple acquisitions and one uplink|(((
809 809  OK
782 +(% style="color:#037691" %)**aa:**(%%)
783 +**0:** means disable this function and use TDC to send packets.
784 +**1:** means enable this function, use the method of multiple acquisitions to send packets.
785 +(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
786 +(% style="color:#037691" %)**cc: **(%%)the number of collection times, the value is 1~~120
810 810  )))
811 811  
812 812  (% style="color:blue" %)**Downlink Command: 0xAE**
image-20230225154759-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -468.9 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0