Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/27 10:31
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -60,6 +60,7 @@ 60 60 * 8500mAh Battery for long term use 61 61 * Controllable 3.3v,5v and 12v output to power external sensor 62 62 63 + 63 63 == 1.3 Specification == 64 64 65 65 ... ... @@ -106,6 +106,7 @@ 106 106 * Sleep Mode: 5uA @ 3.3v 107 107 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 108 108 110 + 109 109 == 1.4 Probe Types == 110 110 111 111 === 1.4.1 Thread Installation Type === ... ... @@ -124,6 +124,7 @@ 124 124 * Operating temperature: -20℃~~60℃ 125 125 * Connector Type: Various Types, see order info 126 126 129 + 127 127 === 1.4.2 Immersion Type === 128 128 129 129 ... ... @@ -133,13 +133,11 @@ 133 133 * Measuring Range: Measure range can be customized, up to 100m. 134 134 * Accuracy: 0.2% F.S 135 135 * Long-Term Stability: ±0.2% F.S / Year 136 -* Overload 200% F.S 137 -* Zero Temperature Drift: ±2% F.S) 138 -* FS Temperature Drift: ±2% F.S 139 139 * Storage temperature: -30℃~~80℃ 140 -* Operating temperature: -40℃~~85℃140 +* Operating temperature: 0℃~~50℃ 141 141 * Material: 316 stainless steels 142 142 143 + 143 143 == 1.5 Probe Dimension == 144 144 145 145 ... ... @@ -210,6 +210,7 @@ 210 210 ))) 211 211 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 212 212 214 + 213 213 == 1.9 Pin Mapping == 214 214 215 215 ... ... @@ -392,9 +392,6 @@ 392 392 [[image:1675144608950-310.png]] 393 393 394 394 395 -=== === 396 - 397 - 398 398 === 2.3.3 Battery Info === 399 399 400 400 ... ... @@ -419,7 +419,6 @@ 419 419 |PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 420 420 |PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure 421 421 422 - 423 423 The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value. 424 424 425 425 ... ... @@ -426,7 +426,7 @@ 426 426 === 2.3.5 0~~20mA value (IDC_IN) === 427 427 428 428 429 -The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level. 427 +The output value from **Pressure Probe**, use together with Probe Model to get the pressure value or water level. 430 430 431 431 (% style="color:#037691" %)**Example**: 432 432 ... ... @@ -433,6 +433,11 @@ 433 433 27AE(H) = 10158 (D)/1000 = 10.158mA. 434 434 435 435 434 +Instead of pressure probe, User can also connect a general 4~~20mA in this port to support different types of 4~~20mA sensors. below is the connection example: 435 + 436 +[[image:image-20230225154759-1.png||height="408" width="741"]] 437 + 438 + 436 436 === 2.3.6 0~~30V value ( pin VDC_IN) === 437 437 438 438 ... ... @@ -465,6 +465,7 @@ 465 465 466 466 0x01: Interrupt Uplink Packet. 467 467 471 + 468 468 === (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 === 469 469 470 470 ... ... @@ -563,17 +563,18 @@ 563 563 [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]] 564 564 565 565 566 -= 3. Configure PS-LB via AT Command or LoRaWAN Downlink=570 += 3. Configure PS-LB = 567 567 572 +== 3.1 Configure Methods == 568 568 569 - Use can configurePS-LBviaATCommand orLoRaWANDownlink.574 +PS-LB-NA supports below configure method: 570 570 571 -* AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]]. 572 -* LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 576 +* AT Command via Bluetooth Connection (**Recommand Way**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 577 +* AT Command via UART Connection : See [[FAQ>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/#H7.FAQ]]. 578 +* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 573 573 574 -There are two kinds of commands to configure PS-LB, they are: 575 575 576 - * (% style="color:#037691"%)**General Commands**581 +== 3.2 General Commands == 577 577 578 578 These commands are to configure: 579 579 ... ... @@ -580,17 +580,18 @@ 580 580 * General system settings like: uplink interval. 581 581 * LoRaWAN protocol & radio related command. 582 582 583 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 588 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 584 584 585 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 590 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 586 586 587 587 588 -* (% style="color:#037691" %)**Commands special design for PS-LB** 589 589 594 +== 3.3 Commands special design for PS-LB == 595 + 590 590 These commands only valid for PS-LB, as below: 591 591 592 592 593 -== 3.1 Set Transmit Interval Time == 599 +=== 3.3.1 Set Transmit Interval Time === 594 594 595 595 596 596 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -618,9 +618,10 @@ 618 618 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 619 619 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 620 620 621 -== 3.2 Set Interrupt Mode == 622 622 628 +=== 3.3.2 Set Interrupt Mode === 623 623 630 + 624 624 Feature, Set Interrupt mode for GPIO_EXIT. 625 625 626 626 (% style="color:blue" %)**AT Command: AT+INTMOD** ... ... @@ -649,9 +649,10 @@ 649 649 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 650 650 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 651 651 652 -== 3.3 Set the output time == 653 653 660 +=== 3.3.3 Set the output time === 654 654 662 + 655 655 Feature, Control the output 3V3 , 5V or 12V. 656 656 657 657 (% style="color:blue" %)**AT Command: AT+3V3T** ... ... @@ -718,9 +718,10 @@ 718 718 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 719 719 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 720 720 721 -== 3.4 Set the Probe Model == 722 722 730 +=== 3.3.4 Set the Probe Model === 723 723 732 + 724 724 Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value. 725 725 726 726 **AT Command: AT** **+PROBE** ... ... @@ -748,7 +748,6 @@ 748 748 |AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK 749 749 |AT +PROBE =0000|Initial state, no settings.|OK 750 750 751 - 752 752 **Downlink Command: 0x08** 753 753 754 754 Format: Command Code (0x08) followed by 2 bytes. ... ... @@ -756,9 +756,10 @@ 756 756 * Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 757 757 * Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 758 758 759 -== 3.5 Multiple collections are one uplink(Since firmware V1.1) == 760 760 768 +=== 3.3.5 Multiple collections are one uplink(Since firmware V1.1) === 761 761 770 + 762 762 Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. 763 763 764 764 (% style="color:blue" %)**AT Command: AT** **+STDC** ... ... @@ -790,7 +790,6 @@ 790 790 OK 791 791 ))) 792 792 793 - 794 794 (% style="color:blue" %)**Downlink Command: 0xAE** 795 795 796 796 Format: Command Code (0x08) followed by 5 bytes. ... ... @@ -797,107 +797,35 @@ 797 797 798 798 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 799 799 800 -= 4. Battery & how to replace = 801 801 802 -= =4.1BatteryType ==809 += 4. Battery & Power Consumption = 803 803 811 +PS-LB-NA uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 804 804 805 - PS-LBisequippedwitha[[8500mAHER26500 Li-SOCI2battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable batterywithlow dischargete targeting for 8~~10yearsuse. This type of battery is commonly used in IoT target for long-term running,suchas water meter.813 + [[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 806 806 807 -The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 808 808 809 - [[image:1675146710956-626.png]]816 += 5. OTA firmware update = 810 810 811 811 812 -Minimum Working Voltage for the PS-LB: 813 - 814 -PS-LB: 2.45v ~~ 3.6v 815 - 816 - 817 -== 4.2 Replace Battery == 818 - 819 - 820 -Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 821 - 822 -And make sure the positive and negative pins match. 823 - 824 - 825 -== 4.3 Power Consumption Analyze == 826 - 827 - 828 -Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 829 - 830 -Instruction to use as below: 831 - 832 -(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]] 833 - 834 -(% style="color:blue" %)**Step 2:**(%%) Open it and choose 835 - 836 -* Product Model 837 -* Uplink Interval 838 -* Working Mode 839 - 840 -And the Life expectation in difference case will be shown on the right. 841 - 842 -[[image:1675146895108-304.png]] 843 - 844 - 845 -The battery related documents as below: 846 - 847 -* [[Battery Dimension>>https://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]], 848 -* [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]] 849 -* [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]] 850 - 851 -[[image:image-20230131145708-3.png]] 852 - 853 - 854 -=== 4.3.1 Battery Note === 855 - 856 - 857 -The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 858 - 859 - 860 -=== 4.3.2 Replace the battery === 861 - 862 - 863 -You can change the battery in the PS-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 864 - 865 -The default battery pack of PS-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 866 - 867 - 868 -= 5. Remote Configure device = 869 - 870 -== 5.1 Connect via BLE == 871 - 872 - 873 -Please see this instruction for how to configure via BLE: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]] 874 - 875 - 876 -== 5.2 AT Command Set == 877 - 878 - 879 - 880 -= 6. OTA firmware update = 881 - 882 - 883 883 Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 884 884 885 885 886 -= 7. FAQ =822 += 6. FAQ = 887 887 888 -== 7.1 How to use AT Command to access device? ==824 +== 6.1 How to use AT Command via UART to access device? == 889 889 890 890 891 891 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 892 892 893 893 894 -== 7.2 How to update firmware via UART port? ==830 +== 6.2 How to update firmware via UART port? == 895 895 896 896 897 897 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 898 898 899 899 900 -== 7.3 How to change the LoRa Frequency Bands/Region? ==836 +== 6.3 How to change the LoRa Frequency Bands/Region? == 901 901 902 902 903 903 You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]. ... ... @@ -904,13 +904,13 @@ 904 904 When downloading the images, choose the required image file for download. 905 905 906 906 907 -= 8. Order Info =843 += 7. Order Info = 908 908 909 909 910 910 [[image:image-20230131153105-4.png]] 911 911 912 912 913 -= 9. Packing Info =849 += 8. Packing Info = 914 914 915 915 916 916 (% style="color:#037691" %)**Package Includes**: ... ... @@ -924,9 +924,10 @@ 924 924 * Package Size / pcs : cm 925 925 * Weight / pcs : g 926 926 927 -= 10. Support = 928 928 864 += 9. Support = 929 929 866 + 930 930 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 931 931 932 932 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]