Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 16:01
Change comment:
Uploaded new attachment "image-20230222174559-1.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -58,8 +58,9 @@ 58 58 * Uplink on periodically 59 59 * Downlink to change configure 60 60 * 8500mAh Battery for long term use 61 -* Controllable 3.3v,5v and 12v output to power external sensor 62 62 62 + 63 + 63 63 == 1.3 Specification == 64 64 65 65 ... ... @@ -106,6 +106,8 @@ 106 106 * Sleep Mode: 5uA @ 3.3v 107 107 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 108 108 110 + 111 + 109 109 == 1.4 Probe Types == 110 110 111 111 === 1.4.1 Thread Installation Type === ... ... @@ -124,6 +124,8 @@ 124 124 * Operating temperature: -20℃~~60℃ 125 125 * Connector Type: Various Types, see order info 126 126 130 + 131 + 127 127 === 1.4.2 Immersion Type === 128 128 129 129 ... ... @@ -140,6 +140,8 @@ 140 140 * Operating temperature: -40℃~~85℃ 141 141 * Material: 316 stainless steels 142 142 148 + 149 + 143 143 == 1.5 Probe Dimension == 144 144 145 145 ... ... @@ -210,6 +210,8 @@ 210 210 ))) 211 211 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 212 212 220 + 221 + 213 213 == 1.9 Pin Mapping == 214 214 215 215 ... ... @@ -306,6 +306,15 @@ 306 306 307 307 == 2.3 Uplink Payload == 308 308 318 + 319 +Uplink payloads have two types: 320 + 321 +* Distance Value: Use FPORT=2 322 +* Other control commands: Use other FPORT fields. 323 + 324 +The application server should parse the correct value based on FPORT settings. 325 + 326 + 309 309 === 2.3.1 Device Status, FPORT~=5 === 310 310 311 311 ... ... @@ -392,12 +392,23 @@ 392 392 [[image:1675144608950-310.png]] 393 393 394 394 395 -=== === 413 +=== 2.3.3 Sensor value, FPORT~=7 === 396 396 397 397 398 -=== 2.3.3 Battery Info === 416 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %) 417 +|(% style="width:94px" %)((( 418 +**Size(bytes)** 419 +)))|(% style="width:43px" %)2|(% style="width:367px" %)n 420 +|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)((( 421 +Voltage value, each 2 bytes is a set of voltage values. 422 +))) 399 399 424 +[[image:image-20230220171300-1.png||height="207" width="863"]] 400 400 426 + 427 +=== 2.3.4 Battery Info === 428 + 429 + 401 401 Check the battery voltage for PS-LB. 402 402 403 403 Ex1: 0x0B45 = 2885mV ... ... @@ -405,27 +405,25 @@ 405 405 Ex2: 0x0B49 = 2889mV 406 406 407 407 408 -=== 2.3. 4Probe Model ===437 +=== 2.3.5 Probe Model === 409 409 410 410 411 -PS-LB has different kind of probe, 4~~20mA represent the full scale of the measuring range. So a 12mA output means different meaning for different probe.440 +PS-LB has different kind of probe, 0~~20mA represent the full scale of the measuring range. So a 15mA output means different meaning for different probe. 412 412 413 413 414 414 For example. 415 415 416 416 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 417 -|**Part Number**|**Probe Used**|**4~~20mA scale**|**Example: 12mA meaning** 418 -|PS-LB-I3|immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water 419 -|PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 420 -|PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure 446 +|(% style="width:111px" %)**Part Number**|(% style="width:158px" %)**Probe Used**|**0~~20mA scale**|**Example: 10mA meaning** 447 +|(% style="width:111px" %)PS-LB-I3|(% style="width:158px" %)immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water 448 +|(% style="width:111px" %)PS-LB-I5|(% style="width:158px" %)immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 421 421 450 +The probe model field provides the convenient for server to identical how it should parse the 0~~20mA sensor value and get the correct value. 422 422 423 -The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value. 424 424 453 +=== 2.3.6 0~~20mA value (IDC_IN) === 425 425 426 -=== 2.3.5 0~~20mA value (IDC_IN) === 427 427 428 - 429 429 The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level. 430 430 431 431 (% style="color:#037691" %)**Example**: ... ... @@ -433,7 +433,7 @@ 433 433 27AE(H) = 10158 (D)/1000 = 10.158mA. 434 434 435 435 436 -=== 2.3. 60~~30V value ( pin VDC_IN) ===463 +=== 2.3.7 0~~30V value ( pin VDC_IN) === 437 437 438 438 439 439 Measure the voltage value. The range is 0 to 30V. ... ... @@ -443,7 +443,7 @@ 443 443 138E(H) = 5006(D)/1000= 5.006V 444 444 445 445 446 -=== 2.3. 7IN1&IN2&INT pin ===473 +=== 2.3.8 IN1&IN2&INT pin === 447 447 448 448 449 449 IN1 and IN2 are used as digital input pins. ... ... @@ -465,24 +465,7 @@ 465 465 466 466 0x01: Interrupt Uplink Packet. 467 467 468 -=== (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 === 469 469 470 - 471 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %) 472 -|(% style="width:94px" %)((( 473 -**Size(bytes)** 474 -)))|(% style="width:43px" %)2|(% style="width:367px" %)n 475 -|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)((( 476 -Voltage value, each 2 bytes is a set of voltage values. 477 -))) 478 - 479 -[[image:image-20230220171300-1.png||height="207" width="863"]] 480 - 481 -Multiple sets of data collected are displayed in this form: 482 - 483 -[voltage value1], [voltage value2], [voltage value3],…[voltage value n/2] 484 - 485 - 486 486 === 2.3.9 Decode payload in The Things Network === 487 487 488 488 ... ... @@ -618,6 +618,8 @@ 618 618 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 619 619 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 620 620 631 + 632 + 621 621 == 3.2 Set Interrupt Mode == 622 622 623 623 ... ... @@ -630,14 +630,14 @@ 630 630 |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 631 631 0 632 632 OK 633 -the mode is 0 = DisableInterrupt645 +the mode is 0 = No interruption 634 634 ))) 635 635 |(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 636 636 Set Transmit Interval 637 - 0. (Disable Interrupt),638 - ~1. (Trigger by rising and falling edge)639 - 2. (Trigger by falling edge)640 - 3. (Trigger by rising edge)649 +~1. (Disable Interrupt), 650 +2. (Trigger by rising and falling edge) 651 +3. (Trigger by falling edge) 652 +4. (Trigger by rising edge) 641 641 )))|(% style="width:157px" %)OK 642 642 643 643 (% style="color:blue" %)**Downlink Command: 0x06** ... ... @@ -649,6 +649,8 @@ 649 649 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 650 650 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 651 651 664 + 665 + 652 652 == 3.3 Set the output time == 653 653 654 654 ... ... @@ -718,43 +718,35 @@ 718 718 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 719 719 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 720 720 721 -== 3.4 Set the Probe Model == 722 722 723 723 724 - Usersneed to configure this parameter according to the type of external probe.In this way, theserver can decode accordingtothis value,and convert the current valueoutputby thesensor into waterdepth or pressure value.737 +== 3.4 Set the Probe Model == 725 725 726 -**AT Command: AT** **+PROBE** 727 727 728 -AT+PROBE =aabb740 +(% style="color:blue" %)**AT Command: AT** **+PROBE** 729 729 730 -When aa=00, it is the water depth mode, and the current is converted into the water depth value; bb is the probe at a depth of several meters. 731 - 732 -When aa=01, it is the pressure mode, which converts the current into a pressure value; 733 - 734 -bb represents which type of pressure sensor it is. 735 - 736 -(A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C) 737 - 738 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 739 -|**Command Example**|**Function**|**Response** 740 -|AT +PROBE =?|Get or Set the probe model.|0 742 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:448px" %) 743 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 204px;" %)**Function**|=(% style="width: 85px;" %)**Response** 744 +|(% style="width:154px" %)AT +PROBE =?|(% style="width:204px" %)Get or Set the probe model.|(% style="width:85px" %)((( 745 +0 741 741 OK 742 -|AT +PROBE =0003|Set water depth sensor mode, 3m type.|OK 743 -|((( 744 -AT +PROBE =000A 747 +))) 748 +|(% style="width:154px" %)AT +PROBE =0003|(% style="width:204px" %)Set water depth sensor mode, 3m type.|(% style="width:85px" %)OK 749 +|(% style="width:154px" %)AT +PROBE =0101|(% style="width:204px" %)Set pressure transmitters mode, first type.|(% style="width:85px" %)((( 750 +OK 751 +))) 752 +|(% style="width:154px" %)AT +PROBE =0000|(% style="width:204px" %)Initial state, no settings.|(% style="width:85px" %)((( 753 +OK 754 +))) 745 745 746 - 747 -)))|Set water depth sensor mode, 10m type.|OK 748 -|AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK 749 -|AT +PROBE =0000|Initial state, no settings.|OK 756 +(% style="color:blue" %)**Downlink Command: 0x08** 750 750 758 +Format: Command Code (0x08) followed by 2 bytes. 751 751 752 -**Downlink Command: 0x08** 760 +* Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 761 +* Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 753 753 754 -Format: Command Code (0x08) followed by 2 bytes. 755 755 756 -* Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 757 -* Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 758 758 759 759 == 3.5 Multiple collections are one uplink(Since firmware V1.1) == 760 760 ... ... @@ -763,34 +763,23 @@ 763 763 764 764 (% style="color:blue" %)**AT Command: AT** **+STDC** 765 765 766 -AT+STDC=aa,bb,bb 767 - 768 -(% style="color:#037691" %)**aa:**(%%) 769 -**0:** means disable this function and use TDC to send packets. 770 -**1:** means enable this function, use the method of multiple acquisitions to send packets. 771 -(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535 772 -(% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120 773 - 774 774 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 775 -|**Command Example**|**Function**|**Response** 776 -|AT+STDC=?|Get the mode of multiple acquisitions and one uplink.|1,10,18 773 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response** 774 +|(% style="width:156px" %)AT+STDC=?|(% style="width:137px" %)((( 775 +Get the mode of multiple acquisitions and one uplink 776 +)))|((( 777 +1,10,18 777 777 OK 778 -|AT+STDC=1,10,18|Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|((( 779 -Attention:Take effect after ATZ 780 - 781 -OK 782 782 ))) 783 -|AT+STDC=0, 0,0|((( 784 -Use the TDC interval to send packets.(default) 785 - 786 - 787 -)))|((( 788 -Attention:Take effect after ATZ 789 - 780 +|(% style="width:156px" %)AT+STDC=1,10,18|(% style="width:137px" %)Set the mode of multiple acquisitions and one uplink|((( 790 790 OK 782 +(% style="color:#037691" %)**aa:**(%%) 783 +**0:** means disable this function and use TDC to send packets. 784 +**1:** means enable this function, use the method of multiple acquisitions to send packets. 785 +(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535 786 +(% style="color:#037691" %)**cc: **(%%)the number of collection times, the value is 1~~120 791 791 ))) 792 792 793 - 794 794 (% style="color:blue" %)**Downlink Command: 0xAE** 795 795 796 796 Format: Command Code (0x08) followed by 5 bytes. ... ... @@ -797,6 +797,8 @@ 797 797 798 798 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 799 799 795 + 796 + 800 800 = 4. Battery & how to replace = 801 801 802 802 == 4.1 Battery Type == ... ... @@ -924,6 +924,8 @@ 924 924 * Package Size / pcs : cm 925 925 * Weight / pcs : g 926 926 924 + 925 + 927 927 = 10. Support = 928 928 929 929