... ... @@ -58,8 +58,9 @@
58 58  * Uplink on periodically
59 59  * Downlink to change configure
60 60  * 8500mAh Battery for long term use
61 -* Controllable 3.3v,5v and 12v output to power external sensor
62 62  
62 +
63 +
63 63  == 1.3 Specification ==
64 64  
65 65  
... ... @@ -106,6 +106,8 @@
106 106  * Sleep Mode: 5uA @ 3.3v
107 107  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
108 108  
110 +
111 +
109 109  == 1.4 Probe Types ==
110 110  
111 111  === 1.4.1 Thread Installation Type ===
... ... @@ -124,6 +124,8 @@
124 124  * Operating temperature: -20℃~~60℃
125 125  * Connector Type: Various Types, see order info
126 126  
130 +
131 +
127 127  === 1.4.2 Immersion Type ===
128 128  
129 129  
... ... @@ -140,6 +140,8 @@
140 140  * Operating temperature: -40℃~~85℃
141 141  * Material: 316 stainless steels
142 142  
148 +
149 +
143 143  == 1.5 Probe Dimension ==
144 144  
145 145  
... ... @@ -210,6 +210,8 @@
210 210  )))
211 211  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.
212 212  
220 +
221 +
213 213  == 1.9 Pin Mapping ==
214 214  
215 215  
... ... @@ -306,6 +306,15 @@
306 306  
307 307  == 2.3 ​Uplink Payload ==
308 308  
318 +
319 +Uplink payloads have two types:
320 +
321 +* Distance Value: Use FPORT=2
322 +* Other control commands: Use other FPORT fields.
323 +
324 +The application server should parse the correct value based on FPORT settings.
325 +
326 +
309 309  === 2.3.1 Device Status, FPORT~=5 ===
310 310  
311 311  
... ... @@ -392,12 +392,23 @@
392 392  [[image:1675144608950-310.png]]
393 393  
394 394  
395 -=== ===
413 +=== 2.3.3 Sensor value, FPORT~=7 ===
396 396  
397 397  
398 -=== 2.3.3 Battery Info ===
416 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
417 +|(% style="width:94px" %)(((
418 +**Size(bytes)**
419 +)))|(% style="width:43px" %)2|(% style="width:367px" %)n
420 +|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)(((
421 +Voltage value, each 2 bytes is a set of voltage values.
422 +)))
399 399  
424 +[[image:image-20230220171300-1.png||height="207" width="863"]]
400 400  
426 +
427 +=== 2.3.4 Battery Info ===
428 +
429 +
401 401  Check the battery voltage for PS-LB.
402 402  
403 403  Ex1: 0x0B45 = 2885mV
... ... @@ -405,27 +405,25 @@
405 405  Ex2: 0x0B49 = 2889mV
406 406  
407 407  
408 -=== 2.3.4 Probe Model ===
437 +=== 2.3.5 Probe Model ===
409 409  
410 410  
411 -PS-LB has different kind of probe, 4~~20mA represent the full scale of the measuring range. So a 12mA output means different meaning for different probe. 
440 +PS-LB has different kind of probe, 0~~20mA represent the full scale of the measuring range. So a 15mA output means different meaning for different probe. 
412 412  
413 413  
414 414  For example.
415 415  
416 416  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
417 -|**Part Number**|**Probe Used**|**4~~20mA scale**|**Example: 12mA meaning**
418 -|PS-LB-I3|immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
419 -|PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
420 -|PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure
446 +|(% style="width:111px" %)**Part Number**|(% style="width:158px" %)**Probe Used**|**0~~20mA scale**|**Example: 10mA meaning**
447 +|(% style="width:111px" %)PS-LB-I3|(% style="width:158px" %)immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
448 +|(% style="width:111px" %)PS-LB-I5|(% style="width:158px" %)immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
421 421  
450 +The probe model field provides the convenient for server to identical how it should parse the 0~~20mA sensor value and get the correct value.
422 422  
423 -The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value.
424 424  
453 +=== 2.3.6 0~~20mA value (IDC_IN) ===
425 425  
426 -=== 2.3.5 0~~20mA value (IDC_IN) ===
427 427  
428 -
429 429  The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level.
430 430  
431 431  (% style="color:#037691" %)**Example**:
... ... @@ -433,7 +433,7 @@
433 433  27AE(H) = 10158 (D)/1000 = 10.158mA.
434 434  
435 435  
436 -=== 2.3.6 0~~30V value ( pin VDC_IN) ===
463 +=== 2.3.7 0~~30V value ( pin VDC_IN) ===
437 437  
438 438  
439 439  Measure the voltage value. The range is 0 to 30V.
... ... @@ -443,7 +443,7 @@
443 443  138E(H) = 5006(D)/1000= 5.006V
444 444  
445 445  
446 -=== 2.3.7 IN1&IN2&INT pin ===
473 +=== 2.3.8 IN1&IN2&INT pin ===
447 447  
448 448  
449 449  IN1 and IN2 are used as digital input pins.
... ... @@ -465,24 +465,7 @@
465 465  
466 466  0x01: Interrupt Uplink Packet.
467 467  
468 -=== (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 ===
469 469  
470 -
471 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
472 -|(% style="width:94px" %)(((
473 -**Size(bytes)**
474 -)))|(% style="width:43px" %)2|(% style="width:367px" %)n
475 -|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)(((
476 -Voltage value, each 2 bytes is a set of voltage values.
477 -)))
478 -
479 -[[image:image-20230220171300-1.png||height="207" width="863"]]
480 -
481 -Multiple sets of data collected are displayed in this form:
482 -
483 -[voltage value1], [voltage value2], [voltage value3],…[voltage value n/2]
484 -
485 -
486 486  === 2.3.9 ​Decode payload in The Things Network ===
487 487  
488 488  
... ... @@ -618,6 +618,8 @@
618 618  * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
619 619  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
620 620  
631 +
632 +
621 621  == 3.2 Set Interrupt Mode ==
622 622  
623 623  
... ... @@ -630,14 +630,14 @@
630 630  |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
631 631  0
632 632  OK
633 -the mode is 0 =Disable Interrupt
645 +the mode is 0 = No interruption
634 634  )))
635 635  |(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
636 636  Set Transmit Interval
637 -0. (Disable Interrupt),
638 -~1. (Trigger by rising and falling edge)
639 -2. (Trigger by falling edge)
640 -3. (Trigger by rising edge)
649 +~1. (Disable Interrupt),
650 +2. (Trigger by rising and falling edge)
651 +3. (Trigger by falling edge)
652 +4. (Trigger by rising edge)
641 641  )))|(% style="width:157px" %)OK
642 642  
643 643  (% style="color:blue" %)**Downlink Command: 0x06**
... ... @@ -649,6 +649,8 @@
649 649  * Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
650 650  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
651 651  
664 +
665 +
652 652  == 3.3 Set the output time ==
653 653  
654 654  
... ... @@ -718,43 +718,35 @@
718 718  * Example 5: Downlink Payload: 070301F4  **~-~-->**  AT+12VT=500
719 719  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
720 720  
721 -== 3.4 Set the Probe Model ==
722 722  
723 723  
724 -Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value.
737 +== 3.4 Set the Probe Model ==
725 725  
726 -**AT Command: AT** **+PROBE**
727 727  
728 -AT+PROBE=aabb
740 +(% style="color:blue" %)**AT Command: AT** **+PROBE**
729 729  
730 -When aa=00, it is the water depth mode, and the current is converted into the water depth value; bb is the probe at a depth of several meters.
731 -
732 -When aa=01, it is the pressure mode, which converts the current into a pressure value;
733 -
734 -bb represents which type of pressure sensor it is.
735 -
736 -(A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C)
737 -
738 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
739 -|**Command Example**|**Function**|**Response**
740 -|AT +PROBE =?|Get or Set the probe model.|0
742 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:448px" %)
743 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 204px;" %)**Function**|=(% style="width: 85px;" %)**Response**
744 +|(% style="width:154px" %)AT +PROBE =?|(% style="width:204px" %)Get or Set the probe model.|(% style="width:85px" %)(((
745 +0
741 741  OK
742 -|AT +PROBE =0003|Set water depth sensor mode, 3m type.|OK
743 -|(((
744 -AT +PROBE =000A
747 +)))
748 +|(% style="width:154px" %)AT +PROBE =0003|(% style="width:204px" %)Set water depth sensor mode, 3m type.|(% style="width:85px" %)OK
749 +|(% style="width:154px" %)AT +PROBE =0101|(% style="width:204px" %)Set pressure transmitters mode, first type.|(% style="width:85px" %)(((
750 +OK
751 +)))
752 +|(% style="width:154px" %)AT +PROBE =0000|(% style="width:204px" %)Initial state, no settings.|(% style="width:85px" %)(((
753 +OK
754 +)))
745 745  
746 -
747 -)))|Set water depth sensor mode, 10m type.|OK
748 -|AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK
749 -|AT +PROBE =0000|Initial state, no settings.|OK
756 +(% style="color:blue" %)**Downlink Command: 0x08**
750 750  
758 +Format: Command Code (0x08) followed by 2 bytes.
751 751  
752 -**Downlink Command: 0x08**
760 +* Example 1: Downlink Payload: 080003  **~-~-->**  AT+PROBE=0003
761 +* Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
753 753  
754 -Format: Command Code (0x08) followed by 2 bytes.
755 755  
756 -* Example 1: Downlink Payload: 080003  **~-~-->**  AT+PROBE=0003
757 -* Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
758 758  
759 759  == 3.5 Multiple collections are one uplink(Since firmware V1.1) ==
760 760  
... ... @@ -763,34 +763,23 @@
763 763  
764 764  (% style="color:blue" %)**AT Command: AT** **+STDC**
765 765  
766 -AT+STDC=aa,bb,bb
767 -
768 -(% style="color:#037691" %)**aa:**(%%)
769 -**0:** means disable this function and use TDC to send packets.
770 -**1:** means enable this function, use the method of multiple acquisitions to send packets.
771 -(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
772 -(% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120
773 -
774 774  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
775 -|**Command Example**|**Function**|**Response**
776 -|AT+STDC=?|Get the mode of multiple acquisitions and one uplink.|1,10,18
773 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response**
774 +|(% style="width:156px" %)AT+STDC=?|(% style="width:137px" %)(((
775 +Get the mode of multiple acquisitions and one uplink
776 +)))|(((
777 +1,10,18
777 777  OK
778 -|AT+STDC=1,10,18|Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|(((
779 -Attention:Take effect after ATZ
780 -
781 -OK
782 782  )))
783 -|AT+STDC=0, 0,0|(((
784 -Use the TDC interval to send packets.(default)
785 -
786 -
787 -)))|(((
788 -Attention:Take effect after ATZ
789 -
780 +|(% style="width:156px" %)AT+STDC=1,10,18|(% style="width:137px" %)Set the mode of multiple acquisitions and one uplink|(((
790 790  OK
782 +(% style="color:#037691" %)**aa:**(%%)
783 +**0:** means disable this function and use TDC to send packets.
784 +**1:** means enable this function, use the method of multiple acquisitions to send packets.
785 +(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
786 +(% style="color:#037691" %)**cc: **(%%)the number of collection times, the value is 1~~120
791 791  )))
792 792  
793 -
794 794  (% style="color:blue" %)**Downlink Command: 0xAE**
795 795  
796 796  Format: Command Code (0x08) followed by 5 bytes.
... ... @@ -797,6 +797,8 @@
797 797  
798 798  * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->**  AT+STDC=1,600,18
799 799  
795 +
796 +
800 800  = 4. Battery & how to replace =
801 801  
802 802  == 4.1 Battery Type ==
... ... @@ -924,6 +924,8 @@
924 924  * Package Size / pcs : cm
925 925  * Weight / pcs : g
926 926  
924 +
925 +
927 927  = 10. Support =
928 928  
929 929  