Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/27 10:31
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Edwin - Content
-
... ... @@ -136,11 +136,8 @@ 136 136 * Measuring Range: Measure range can be customized, up to 100m. 137 137 * Accuracy: 0.2% F.S 138 138 * Long-Term Stability: ±0.2% F.S / Year 139 -* Overload 200% F.S 140 -* Zero Temperature Drift: ±2% F.S) 141 -* FS Temperature Drift: ±2% F.S 142 142 * Storage temperature: -30℃~~80℃ 143 -* Operating temperature: -40℃~~85℃140 +* Operating temperature: 0℃~~50℃ 144 144 * Material: 316 stainless steels 145 145 146 146 ... ... @@ -397,9 +397,6 @@ 397 397 [[image:1675144608950-310.png]] 398 398 399 399 400 -=== === 401 - 402 - 403 403 === 2.3.3 Battery Info === 404 404 405 405 ... ... @@ -424,8 +424,6 @@ 424 424 |PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 425 425 |PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure 426 426 427 - 428 - 429 429 The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value. 430 430 431 431 ... ... @@ -432,7 +432,7 @@ 432 432 === 2.3.5 0~~20mA value (IDC_IN) === 433 433 434 434 435 -The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level. 427 +The output value from **Pressure Probe**, use together with Probe Model to get the pressure value or water level. 436 436 437 437 (% style="color:#037691" %)**Example**: 438 438 ... ... @@ -439,6 +439,11 @@ 439 439 27AE(H) = 10158 (D)/1000 = 10.158mA. 440 440 441 441 434 +Instead of pressure probe, User can also connect a general 4~~20mA in this port to support different types of 4~~20mA sensors. below is the connection example: 435 + 436 +[[image:image-20230225154759-1.png||height="408" width="741"]] 437 + 438 + 442 442 === 2.3.6 0~~30V value ( pin VDC_IN) === 443 443 444 444 ... ... @@ -471,6 +471,7 @@ 471 471 472 472 0x01: Interrupt Uplink Packet. 473 473 471 + 474 474 === (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 === 475 475 476 476 ... ... @@ -486,7 +486,7 @@ 486 486 487 487 Multiple sets of data collected are displayed in this form: 488 488 489 -[voltage value1], [voltage value2], [voltage value3],…[voltage value n] 487 +[voltage value1], [voltage value2], [voltage value3],…[voltage value n/2] 490 490 491 491 492 492 === 2.3.9 Decode payload in The Things Network === ... ... @@ -569,17 +569,18 @@ 569 569 [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]] 570 570 571 571 572 -= 3. Configure PS-LB via AT Command or LoRaWAN Downlink=570 += 3. Configure PS-LB = 573 573 572 +== 3.1 Configure Methods == 574 574 575 - Use can configurePS-LBviaATCommand orLoRaWANDownlink.574 +PS-LB-NA supports below configure method: 576 576 577 -* AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]]. 578 -* LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 576 +* AT Command via Bluetooth Connection (**Recommand Way**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 577 +* AT Command via UART Connection : See [[FAQ>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/#H7.FAQ]]. 578 +* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 579 579 580 -There are two kinds of commands to configure PS-LB, they are: 581 581 582 - * (% style="color:#037691"%)**General Commands**581 +== 3.2 General Commands == 583 583 584 584 These commands are to configure: 585 585 ... ... @@ -586,17 +586,18 @@ 586 586 * General system settings like: uplink interval. 587 587 * LoRaWAN protocol & radio related command. 588 588 589 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 588 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 590 590 591 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 590 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 592 592 593 593 594 -* (% style="color:#037691" %)**Commands special design for PS-LB** 595 595 594 +== 3.3 Commands special design for PS-LB == 595 + 596 596 These commands only valid for PS-LB, as below: 597 597 598 598 599 -== 3.1 Set Transmit Interval Time == 599 +=== 3.3.1 Set Transmit Interval Time === 600 600 601 601 602 602 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -625,7 +625,7 @@ 625 625 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 626 626 627 627 628 -== 3.2 Set Interrupt Mode == 628 +=== 3.3.2 Set Interrupt Mode === 629 629 630 630 631 631 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -657,7 +657,7 @@ 657 657 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 658 658 659 659 660 -== 3.3 Set the output time == 660 +=== 3.3.3 Set the output time === 661 661 662 662 663 663 Feature, Control the output 3V3 , 5V or 12V. ... ... @@ -727,7 +727,7 @@ 727 727 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 728 728 729 729 730 -== 3.4 Set the Probe Model == 730 +=== 3.3.4 Set the Probe Model === 731 731 732 732 733 733 Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value. ... ... @@ -757,8 +757,6 @@ 757 757 |AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK 758 758 |AT +PROBE =0000|Initial state, no settings.|OK 759 759 760 - 761 - 762 762 **Downlink Command: 0x08** 763 763 764 764 Format: Command Code (0x08) followed by 2 bytes. ... ... @@ -767,7 +767,7 @@ 767 767 * Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 768 768 769 769 770 -== 3.5 768 +=== 3.3.5 Multiple collections are one uplink(Since firmware V1.1) === 771 771 772 772 773 773 Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. ... ... @@ -801,8 +801,6 @@ 801 801 OK 802 802 ))) 803 803 804 - 805 - 806 806 (% style="color:blue" %)**Downlink Command: 0xAE** 807 807 808 808 Format: Command Code (0x08) followed by 5 bytes. ... ... @@ -810,107 +810,34 @@ 810 810 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 811 811 812 812 813 -= 4. Battery & how toreplace=809 += 4. Battery & Power Consumption = 814 814 815 - ==4.1BatteryType==811 +PS-LB-NA uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 816 816 813 + [[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 817 817 818 -PS-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 819 819 820 - Thedischargecurveis not linearso can’t simply use percentage to showthe battery level.Below is the batteryperformance.816 += 5. OTA firmware update = 821 821 822 -[[image:1675146710956-626.png]] 823 823 824 - 825 -Minimum Working Voltage for the PS-LB: 826 - 827 -PS-LB: 2.45v ~~ 3.6v 828 - 829 - 830 -== 4.2 Replace Battery == 831 - 832 - 833 -Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 834 - 835 -And make sure the positive and negative pins match. 836 - 837 - 838 -== 4.3 Power Consumption Analyze == 839 - 840 - 841 -Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 842 - 843 -Instruction to use as below: 844 - 845 -(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]] 846 - 847 -(% style="color:blue" %)**Step 2:**(%%) Open it and choose 848 - 849 -* Product Model 850 -* Uplink Interval 851 -* Working Mode 852 - 853 -And the Life expectation in difference case will be shown on the right. 854 - 855 -[[image:1675146895108-304.png]] 856 - 857 - 858 -The battery related documents as below: 859 - 860 -* [[Battery Dimension>>https://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]], 861 -* [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]] 862 -* [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]] 863 - 864 -[[image:image-20230131145708-3.png]] 865 - 866 - 867 -=== 4.3.1 Battery Note === 868 - 869 - 870 -The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 871 - 872 - 873 -=== 4.3.2 Replace the battery === 874 - 875 - 876 -You can change the battery in the PS-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 877 - 878 -The default battery pack of PS-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 879 - 880 - 881 -= 5. Remote Configure device = 882 - 883 -== 5.1 Connect via BLE == 884 - 885 - 886 -Please see this instruction for how to configure via BLE: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]] 887 - 888 - 889 -== 5.2 AT Command Set == 890 - 891 - 892 - 893 -= 6. OTA firmware update = 894 - 895 - 896 896 Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 897 897 898 898 899 -= 7. FAQ =822 += 6. FAQ = 900 900 901 -== 7.1 How to use AT Command to access device? ==824 +== 6.1 How to use AT Command via UART to access device? == 902 902 903 903 904 904 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 905 905 906 906 907 -== 7.2 How to update firmware via UART port? ==830 +== 6.2 How to update firmware via UART port? == 908 908 909 909 910 910 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 911 911 912 912 913 -== 7.3 How to change the LoRa Frequency Bands/Region? ==836 +== 6.3 How to change the LoRa Frequency Bands/Region? == 914 914 915 915 916 916 You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]. ... ... @@ -917,13 +917,13 @@ 917 917 When downloading the images, choose the required image file for download. 918 918 919 919 920 -= 8. Order Info =843 += 7. Order Info = 921 921 922 922 923 923 [[image:image-20230131153105-4.png]] 924 924 925 925 926 -= 9. Packing Info =849 += 8. Packing Info = 927 927 928 928 929 929 (% style="color:#037691" %)**Package Includes**: ... ... @@ -938,7 +938,7 @@ 938 938 * Weight / pcs : g 939 939 940 940 941 -= 10. Support =864 += 9. Support = 942 942 943 943 944 944 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- image-20230225154759-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +468.9 KB - Content