From version < 47.1 >
edited by Bei Jinggeng
on 2023/02/22 17:55
To version < 45.6 >
edited by Xiaoling
on 2023/02/21 15:37
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -58,9 +58,9 @@
58 58  * Uplink on periodically
59 59  * Downlink to change configure
60 60  * 8500mAh Battery for long term use
61 -* Controllable 3.3v,5v and 12v output to power external sensor
62 62  
63 63  
63 +
64 64  == 1.3 Specification ==
65 65  
66 66  
... ... @@ -108,6 +108,7 @@
108 108  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
109 109  
110 110  
111 +
111 111  == 1.4 Probe Types ==
112 112  
113 113  === 1.4.1 Thread Installation Type ===
... ... @@ -127,6 +127,7 @@
127 127  * Connector Type: Various Types, see order info
128 128  
129 129  
131 +
130 130  === 1.4.2 Immersion Type ===
131 131  
132 132  
... ... @@ -144,6 +144,7 @@
144 144  * Material: 316 stainless steels
145 145  
146 146  
149 +
147 147  == 1.5 Probe Dimension ==
148 148  
149 149  
... ... @@ -215,6 +215,7 @@
215 215  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.
216 216  
217 217  
221 +
218 218  == 1.9 Pin Mapping ==
219 219  
220 220  
... ... @@ -311,6 +311,15 @@
311 311  
312 312  == 2.3 ​Uplink Payload ==
313 313  
318 +
319 +Uplink payloads have two types:
320 +
321 +* Distance Value: Use FPORT=2
322 +* Other control commands: Use other FPORT fields.
323 +
324 +The application server should parse the correct value based on FPORT settings.
325 +
326 +
314 314  === 2.3.1 Device Status, FPORT~=5 ===
315 315  
316 316  
... ... @@ -397,12 +397,23 @@
397 397  [[image:1675144608950-310.png]]
398 398  
399 399  
400 -=== ===
413 +=== 2.3.3 Sensor value, FPORT~=7 ===
401 401  
402 402  
403 -=== 2.3.3 Battery Info ===
416 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
417 +|(% style="width:94px" %)(((
418 +**Size(bytes)**
419 +)))|(% style="width:43px" %)2|(% style="width:367px" %)n
420 +|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)(((
421 +Voltage value, each 2 bytes is a set of voltage values.
422 +)))
404 404  
424 +[[image:image-20230220171300-1.png||height="207" width="863"]]
405 405  
426 +
427 +=== 2.3.4 Battery Info ===
428 +
429 +
406 406  Check the battery voltage for PS-LB.
407 407  
408 408  Ex1: 0x0B45 = 2885mV
... ... @@ -410,28 +410,25 @@
410 410  Ex2: 0x0B49 = 2889mV
411 411  
412 412  
413 -=== 2.3.4 Probe Model ===
437 +=== 2.3.5 Probe Model ===
414 414  
415 415  
416 -PS-LB has different kind of probe, 4~~20mA represent the full scale of the measuring range. So a 12mA output means different meaning for different probe. 
440 +PS-LB has different kind of probe, 0~~20mA represent the full scale of the measuring range. So a 15mA output means different meaning for different probe. 
417 417  
418 418  
419 419  For example.
420 420  
421 421  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
422 -|**Part Number**|**Probe Used**|**4~~20mA scale**|**Example: 12mA meaning**
423 -|PS-LB-I3|immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
424 -|PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
425 -|PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure
446 +|(% style="width:111px" %)**Part Number**|(% style="width:158px" %)**Probe Used**|**0~~20mA scale**|**Example: 10mA meaning**
447 +|(% style="width:111px" %)PS-LB-I3|(% style="width:158px" %)immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
448 +|(% style="width:111px" %)PS-LB-I5|(% style="width:158px" %)immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
426 426  
427 -
450 +The probe model field provides the convenient for server to identical how it should parse the 0~~20mA sensor value and get the correct value.
428 428  
429 -The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value.
430 430  
453 +=== 2.3.6 0~~20mA value (IDC_IN) ===
431 431  
432 -=== 2.3.5 0~~20mA value (IDC_IN) ===
433 433  
434 -
435 435  The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level.
436 436  
437 437  (% style="color:#037691" %)**Example**:
... ... @@ -439,7 +439,7 @@
439 439  27AE(H) = 10158 (D)/1000 = 10.158mA.
440 440  
441 441  
442 -=== 2.3.6 0~~30V value ( pin VDC_IN) ===
463 +=== 2.3.7 0~~30V value ( pin VDC_IN) ===
443 443  
444 444  
445 445  Measure the voltage value. The range is 0 to 30V.
... ... @@ -449,7 +449,7 @@
449 449  138E(H) = 5006(D)/1000= 5.006V
450 450  
451 451  
452 -=== 2.3.7 IN1&IN2&INT pin ===
473 +=== 2.3.8 IN1&IN2&INT pin ===
453 453  
454 454  
455 455  IN1 and IN2 are used as digital input pins.
... ... @@ -471,24 +471,7 @@
471 471  
472 472  0x01: Interrupt Uplink Packet.
473 473  
474 -=== (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 ===
475 475  
476 -
477 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
478 -|(% style="width:94px" %)(((
479 -**Size(bytes)**
480 -)))|(% style="width:43px" %)2|(% style="width:367px" %)n
481 -|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)(((
482 -Voltage value, each 2 bytes is a set of voltage values.
483 -)))
484 -
485 -[[image:image-20230220171300-1.png||height="207" width="863"]]
486 -
487 -Multiple sets of data collected are displayed in this form:
488 -
489 -[voltage value1], [voltage value2], [voltage value3],…[voltage value n]
490 -
491 -
492 492  === 2.3.9 ​Decode payload in The Things Network ===
493 493  
494 494  
... ... @@ -625,6 +625,7 @@
625 625  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
626 626  
627 627  
632 +
628 628  == 3.2 Set Interrupt Mode ==
629 629  
630 630  
... ... @@ -637,14 +637,14 @@
637 637  |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
638 638  0
639 639  OK
640 -the mode is 0 =Disable Interrupt
645 +the mode is 0 = No interruption
641 641  )))
642 642  |(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
643 643  Set Transmit Interval
644 -0. (Disable Interrupt),
645 -~1. (Trigger by rising and falling edge)
646 -2. (Trigger by falling edge)
647 -3. (Trigger by rising edge)
649 +~1. (Disable Interrupt),
650 +2. (Trigger by rising and falling edge)
651 +3. (Trigger by falling edge)
652 +4. (Trigger by rising edge)
648 648  )))|(% style="width:157px" %)OK
649 649  
650 650  (% style="color:blue" %)**Downlink Command: 0x06**
... ... @@ -657,6 +657,7 @@
657 657  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
658 658  
659 659  
665 +
660 660  == 3.3 Set the output time ==
661 661  
662 662  
... ... @@ -727,46 +727,35 @@
727 727  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
728 728  
729 729  
736 +
730 730  == 3.4 Set the Probe Model ==
731 731  
732 732  
733 -Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value.
740 +(% style="color:blue" %)**AT Command: AT** **+PROBE**
734 734  
735 -**AT Command: AT** **+PROBE**
736 -
737 -AT+PROBE=aabb
738 -
739 -When aa=00, it is the water depth mode, and the current is converted into the water depth value; bb is the probe at a depth of several meters.
740 -
741 -When aa=01, it is the pressure mode, which converts the current into a pressure value;
742 -
743 -bb represents which type of pressure sensor it is.
744 -
745 -(A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C)
746 -
747 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
748 -|**Command Example**|**Function**|**Response**
749 -|AT +PROBE =?|Get or Set the probe model.|0
742 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:448px" %)
743 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 204px;" %)**Function**|=(% style="width: 85px;" %)**Response**
744 +|(% style="width:154px" %)AT +PROBE =?|(% style="width:204px" %)Get or Set the probe model.|(% style="width:85px" %)(((
745 +0
750 750  OK
751 -|AT +PROBE =0003|Set water depth sensor mode, 3m type.|OK
752 -|(((
753 -AT +PROBE =000A
747 +)))
748 +|(% style="width:154px" %)AT +PROBE =0003|(% style="width:204px" %)Set water depth sensor mode, 3m type.|(% style="width:85px" %)OK
749 +|(% style="width:154px" %)AT +PROBE =0101|(% style="width:204px" %)Set pressure transmitters mode, first type.|(% style="width:85px" %)(((
750 +OK
751 +)))
752 +|(% style="width:154px" %)AT +PROBE =0000|(% style="width:204px" %)Initial state, no settings.|(% style="width:85px" %)(((
753 +OK
754 +)))
754 754  
755 -
756 -)))|Set water depth sensor mode, 10m type.|OK
757 -|AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK
758 -|AT +PROBE =0000|Initial state, no settings.|OK
756 +(% style="color:blue" %)**Downlink Command: 0x08**
759 759  
760 -
761 -
762 -**Downlink Command: 0x08**
763 -
764 764  Format: Command Code (0x08) followed by 2 bytes.
765 765  
766 -* Example 1: Downlink Payload: 080003  **~-~-->**  AT+PROBE=0003
767 -* Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
760 +* Example 1: Downlink Payload: 080003  **~-~-->**  AT+PROBE=0003
761 +* Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
768 768  
769 769  
764 +
770 770  == 3.5 Multiple collections are one uplink(Since firmware V1.1) ==
771 771  
772 772  
... ... @@ -774,35 +774,23 @@
774 774  
775 775  (% style="color:blue" %)**AT Command: AT** **+STDC**
776 776  
777 -AT+STDC=aa,bb,bb
778 -
779 -(% style="color:#037691" %)**aa:**(%%)
780 -**0:** means disable this function and use TDC to send packets.
781 -**1:** means enable this function, use the method of multiple acquisitions to send packets.
782 -(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
783 -(% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120
784 -
785 785  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
786 -|**Command Example**|**Function**|**Response**
787 -|AT+STDC=?|Get the mode of multiple acquisitions and one uplink.|1,10,18
773 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response**
774 +|(% style="width:156px" %)AT+STDC=?|(% style="width:137px" %)(((
775 +Get the mode of multiple acquisitions and one uplink
776 +)))|(((
777 +1,10,18
788 788  OK
789 -|AT+STDC=1,10,18|Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|(((
790 -Attention:Take effect after ATZ
791 -
792 -OK
793 793  )))
794 -|AT+STDC=0, 0,0|(((
795 -Use the TDC interval to send packets.(default)
796 -
797 -
798 -)))|(((
799 -Attention:Take effect after ATZ
800 -
780 +|(% style="width:156px" %)AT+STDC=1,10,18|(% style="width:137px" %)Set the mode of multiple acquisitions and one uplink|(((
801 801  OK
782 +(% style="color:#037691" %)**aa:**(%%)
783 +**0:** means disable this function and use TDC to send packets.
784 +**1:** means enable this function, use the method of multiple acquisitions to send packets.
785 +(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
786 +(% style="color:#037691" %)**cc: **(%%)the number of collection times, the value is 1~~120
802 802  )))
803 803  
804 -
805 -
806 806  (% style="color:blue" %)**Downlink Command: 0xAE**
807 807  
808 808  Format: Command Code (0x08) followed by 5 bytes.
... ... @@ -810,6 +810,7 @@
810 810  * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->**  AT+STDC=1,600,18
811 811  
812 812  
796 +
813 813  = 4. Battery & how to replace =
814 814  
815 815  == 4.1 Battery Type ==
... ... @@ -938,6 +938,7 @@
938 938  * Weight / pcs : g
939 939  
940 940  
925 +
941 941  = 10. Support =
942 942  
943 943  
image-20230222174559-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Bei
Size
... ... @@ -1,1 +1,0 @@
1 -19.4 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0