... ... @@ -58,8 +58,10 @@
58 58  * Uplink on periodically
59 59  * Downlink to change configure
60 60  * 8500mAh Battery for long term use
61 +* Controllable 3.3v,5v and 12v output to power external sensor
61 61  
62 62  
64 +
63 63  == 1.3 Specification ==
64 64  
65 65  
... ... @@ -107,6 +107,7 @@
107 107  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
108 108  
109 109  
112 +
110 110  == 1.4 Probe Types ==
111 111  
112 112  === 1.4.1 Thread Installation Type ===
... ... @@ -126,6 +126,7 @@
126 126  * Connector Type: Various Types, see order info
127 127  
128 128  
132 +
129 129  === 1.4.2 Immersion Type ===
130 130  
131 131  
... ... @@ -143,6 +143,7 @@
143 143  * Material: 316 stainless steels
144 144  
145 145  
150 +
146 146  == 1.5 Probe Dimension ==
147 147  
148 148  
... ... @@ -214,6 +214,7 @@
214 214  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.
215 215  
216 216  
222 +
217 217  == 1.9 Pin Mapping ==
218 218  
219 219  
... ... @@ -310,15 +310,6 @@
310 310  
311 311  == 2.3 ​Uplink Payload ==
312 312  
313 -
314 -Uplink payloads have two types:
315 -
316 -* Distance Value: Use FPORT=2
317 -* Other control commands: Use other FPORT fields.
318 -
319 -The application server should parse the correct value based on FPORT settings.
320 -
321 -
322 322  === 2.3.1 Device Status, FPORT~=5 ===
323 323  
324 324  
... ... @@ -405,23 +405,9 @@
405 405  [[image:1675144608950-310.png]]
406 406  
407 407  
408 -=== 2.3.3 Sensor value, FPORT~=7 ===
405 +=== 2.3.3 Battery Info ===
409 409  
410 410  
411 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
412 -|(% style="width:94px" %)(((
413 -**Size(bytes)**
414 -)))|(% style="width:43px" %)2|(% style="width:367px" %)n
415 -|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)(((
416 -Voltage value, each 2 bytes is a set of voltage values.
417 -)))
418 -
419 -[[image:image-20230220171300-1.png||height="207" width="863"]]
420 -
421 -
422 -=== 2.3.4 Battery Info ===
423 -
424 -
425 425  Check the battery voltage for PS-LB.
426 426  
427 427  Ex1: 0x0B45 = 2885mV
... ... @@ -429,26 +429,27 @@
429 429  Ex2: 0x0B49 = 2889mV
430 430  
431 431  
432 -=== 2.3.5 Probe Model ===
415 +=== 2.3.4 Probe Model ===
433 433  
434 434  
435 -PS-LB has different kind of probe, 0~~20mA represent the full scale of the measuring range. So a 15mA output means different meaning for different probe. 
418 +PS-LB has different kind of probe, 4~~20mA represent the full scale of the measuring range. So a 12mA output means different meaning for different probe. 
436 436  
437 437  
438 438  For example.
439 439  
440 440  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
441 -|(% style="width:111px" %)**Part Number**|(% style="width:158px" %)**Probe Used**|**0~~20mA scale**|**Example: 10mA meaning**
442 -|(% style="width:111px" %)PS-LB-I3|(% style="width:158px" %)immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
443 -|(% style="width:111px" %)PS-LB-I5|(% style="width:158px" %)immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
424 +|**Part Number**|**Probe Used**|**4~~20mA scale**|**Example: 12mA meaning**
425 +|PS-LB-I3|immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
426 +|PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
427 +|PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure
444 444  
445 -The probe model field provides the convenient for server to identical how it should parse the 0~~20mA sensor value and get the correct value.
429 +The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value.
446 446  
447 447  
448 -=== 2.3.6 0~~20mA value (IDC_IN) ===
432 +=== 2.3.5 0~~20mA value (IDC_IN) ===
449 449  
450 450  
451 -The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level.
435 +The output value from **Pressure Probe**, use together with Probe Model to get the pressure value or water level.
452 452  
453 453  (% style="color:#037691" %)**Example**:
454 454  
... ... @@ -455,9 +455,14 @@
455 455  27AE(H) = 10158 (D)/1000 = 10.158mA.
456 456  
457 457  
458 -=== 2.3.7 0~~30V value ( pin VDC_IN) ===
442 +Instead of pressure probe, User can also connect a general 4~~20mA in this port to support different types of 4~~20mA sensors. below is the connection example:
459 459  
444 +[[image:image-20230225154759-1.png||height="408" width="741"]]
460 460  
446 +
447 +=== 2.3.6 0~~30V value ( pin VDC_IN) ===
448 +
449 +
461 461  Measure the voltage value. The range is 0 to 30V.
462 462  
463 463  (% style="color:#037691" %)**Example**:
... ... @@ -465,7 +465,7 @@
465 465  138E(H) = 5006(D)/1000= 5.006V
466 466  
467 467  
468 -=== 2.3.8 IN1&IN2&INT pin ===
457 +=== 2.3.7 IN1&IN2&INT pin ===
469 469  
470 470  
471 471  IN1 and IN2 are used as digital input pins.
... ... @@ -488,6 +488,24 @@
488 488  0x01: Interrupt Uplink Packet.
489 489  
490 490  
480 +=== (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 ===
481 +
482 +
483 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
484 +|(% style="width:94px" %)(((
485 +**Size(bytes)**
486 +)))|(% style="width:43px" %)2|(% style="width:367px" %)n
487 +|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)(((
488 +Voltage value, each 2 bytes is a set of voltage values.
489 +)))
490 +
491 +[[image:image-20230220171300-1.png||height="207" width="863"]]
492 +
493 +Multiple sets of data collected are displayed in this form:
494 +
495 +[voltage value1], [voltage value2], [voltage value3],…[voltage value n/2]
496 +
497 +
491 491  === 2.3.9 ​Decode payload in The Things Network ===
492 492  
493 493  
... ... @@ -568,7 +568,6 @@
568 568  [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]
569 569  
570 570  
571 -
572 572  = 3. Configure PS-LB via AT Command or LoRaWAN Downlink =
573 573  
574 574  
... ... @@ -625,6 +625,7 @@
625 625  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
626 626  
627 627  
634 +
628 628  == 3.2 Set Interrupt Mode ==
629 629  
630 630  
... ... @@ -637,14 +637,14 @@
637 637  |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
638 638  0
639 639  OK
640 -the mode is 0 = No interruption
647 +the mode is 0 =Disable Interrupt
641 641  )))
642 642  |(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
643 643  Set Transmit Interval
644 -~1. (Disable Interrupt),
645 -2. (Trigger by rising and falling edge)
646 -3. (Trigger by falling edge)
647 -4. (Trigger by rising edge)
651 +0. (Disable Interrupt),
652 +~1. (Trigger by rising and falling edge)
653 +2. (Trigger by falling edge)
654 +3. (Trigger by rising edge)
648 648  )))|(% style="width:157px" %)OK
649 649  
650 650  (% style="color:blue" %)**Downlink Command: 0x06**
... ... @@ -657,6 +657,7 @@
657 657  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
658 658  
659 659  
667 +
660 660  == 3.3 Set the output time ==
661 661  
662 662  
... ... @@ -727,33 +727,46 @@
727 727  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
728 728  
729 729  
738 +
730 730  == 3.4 Set the Probe Model ==
731 731  
732 732  
733 -(% style="color:blue" %)**AT Command: AT** **+PROBE**
742 +Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value.
734 734  
735 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:448px" %)
736 -|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 204px;" %)**Function**|=(% style="width: 85px;" %)**Response**
737 -|(% style="width:154px" %)AT +PROBE =?|(% style="width:204px" %)Get or Set the probe model.|(% style="width:85px" %)(((
738 -0
744 +**AT Command: AT** **+PROBE**
745 +
746 +AT+PROBE=aabb
747 +
748 +When aa=00, it is the water depth mode, and the current is converted into the water depth value; bb is the probe at a depth of several meters.
749 +
750 +When aa=01, it is the pressure mode, which converts the current into a pressure value;
751 +
752 +bb represents which type of pressure sensor it is.
753 +
754 +(A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C)
755 +
756 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
757 +|**Command Example**|**Function**|**Response**
758 +|AT +PROBE =?|Get or Set the probe model.|0
739 739  OK
740 -)))
741 -|(% style="width:154px" %)AT +PROBE =0003|(% style="width:204px" %)Set water depth sensor mode, 3m type.|(% style="width:85px" %)OK
742 -|(% style="width:154px" %)AT +PROBE =0101|(% style="width:204px" %)Set pressure transmitters mode, first type.|(% style="width:85px" %)(((
743 -OK
744 -)))
745 -|(% style="width:154px" %)AT +PROBE =0000|(% style="width:204px" %)Initial state, no settings.|(% style="width:85px" %)(((
746 -OK
747 -)))
760 +|AT +PROBE =0003|Set water depth sensor mode, 3m type.|OK
761 +|(((
762 +AT +PROBE =000A
748 748  
749 -(% style="color:blue" %)**Downlink Command: 0x08**
764 +
765 +)))|Set water depth sensor mode, 10m type.|OK
766 +|AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK
767 +|AT +PROBE =0000|Initial state, no settings.|OK
750 750  
769 +**Downlink Command: 0x08**
770 +
751 751  Format: Command Code (0x08) followed by 2 bytes.
752 752  
753 -* Example 1: Downlink Payload: 080003  **~-~-->**  AT+PROBE=0003
754 -* Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
773 +* Example 1: Downlink Payload: 080003  **~-~-->**  AT+PROBE=0003
774 +* Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
755 755  
756 756  
777 +
757 757  == 3.5 Multiple collections are one uplink(Since firmware V1.1) ==
758 758  
759 759  
... ... @@ -761,21 +761,31 @@
761 761  
762 762  (% style="color:blue" %)**AT Command: AT** **+STDC**
763 763  
785 +AT+STDC=aa,bb,bb
786 +
787 +(% style="color:#037691" %)**aa:**(%%)
788 +**0:** means disable this function and use TDC to send packets.
789 +**1:** means enable this function, use the method of multiple acquisitions to send packets.
790 +(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
791 +(% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120
792 +
764 764  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
765 -|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response**
766 -|(% style="width:156px" %)AT+STDC=?|(% style="width:137px" %)(((
767 -Get the mode of multiple acquisitions and one uplink
768 -)))|(((
769 -1,10,18
794 +|**Command Example**|**Function**|**Response**
795 +|AT+STDC=?|Get the mode of multiple acquisitions and one uplink.|1,10,18
770 770  OK
797 +|AT+STDC=1,10,18|Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|(((
798 +Attention:Take effect after ATZ
799 +
800 +OK
771 771  )))
772 -|(% style="width:156px" %)AT+STDC=1,10,18|(% style="width:137px" %)Set the mode of multiple acquisitions and one uplink|(((
802 +|AT+STDC=0, 0,0|(((
803 +Use the TDC interval to send packets.(default)
804 +
805 +
806 +)))|(((
807 +Attention:Take effect after ATZ
808 +
773 773  OK
774 -(% style="color:#037691" %)**aa:**(%%)
775 -**0:** means disable this function and use TDC to send packets.
776 -**1:** means enable this function, use the method of multiple acquisitions to send packets.
777 -(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
778 -(% style="color:#037691" %)**cc: **(%%)the number of collection times, the value is 1~~120
779 779  )))
780 780  
781 781  (% style="color:blue" %)**Downlink Command: 0xAE**
... ... @@ -785,6 +785,7 @@
785 785  * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->**  AT+STDC=1,600,18
786 786  
787 787  
819 +
788 788  = 4. Battery & how to replace =
789 789  
790 790  == 4.1 Battery Type ==
... ... @@ -913,6 +913,7 @@
913 913  * Weight / pcs : g
914 914  
915 915  
948 +
916 916  = 10. Support =
917 917  
918 918  
image-20230222174559-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +19.4 KB
Content
image-20230225154759-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +468.9 KB
Content