Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/03 14:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -60,7 +60,6 @@ 60 60 * 8500mAh Battery for long term use 61 61 62 62 63 - 64 64 == 1.3 Specification == 65 65 66 66 ... ... @@ -108,7 +108,6 @@ 108 108 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 109 109 110 110 111 - 112 112 == 1.4 Probe Types == 113 113 114 114 === 1.4.1 Thread Installation Type === ... ... @@ -128,7 +128,6 @@ 128 128 * Connector Type: Various Types, see order info 129 129 130 130 131 - 132 132 === 1.4.2 Immersion Type === 133 133 134 134 ... ... @@ -146,7 +146,6 @@ 146 146 * Material: 316 stainless steels 147 147 148 148 149 - 150 150 == 1.5 Probe Dimension == 151 151 152 152 ... ... @@ -218,7 +218,6 @@ 218 218 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 219 219 220 220 221 - 222 222 == 1.9 Pin Mapping == 223 223 224 224 ... ... @@ -405,7 +405,7 @@ 405 405 |(% style="width:97px" %)((( 406 406 **Size(bytes)** 407 407 )))|(% style="width:48px" %)**2**|(% style="width:71px" %)**2**|(% style="width:98px" %)**2**|(% style="width:73px" %)**2**|(% style="width:122px" %)**1** 408 -|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3. 3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.7IN126IN226INTpin"]]403 +|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.5ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.607E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.707E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.8IN126IN226INTpin"]] 409 409 410 410 [[image:1675144608950-310.png]] 411 411 ... ... @@ -417,7 +417,7 @@ 417 417 |(% style="width:94px" %)((( 418 418 **Size(bytes)** 419 419 )))|(% style="width:43px" %)2|(% style="width:367px" %)n 420 -|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3. 3BatteryInfo"]]|(% style="width:367px" %)(((415 +|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)((( 421 421 Voltage value, each 2 bytes is a set of voltage values. 422 422 ))) 423 423 ... ... @@ -630,7 +630,6 @@ 630 630 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 631 631 632 632 633 - 634 634 == 3.2 Set Interrupt Mode == 635 635 636 636 ... ... @@ -663,7 +663,6 @@ 663 663 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 664 664 665 665 666 - 667 667 == 3.3 Set the output time == 668 668 669 669 ... ... @@ -734,7 +734,6 @@ 734 734 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 735 735 736 736 737 - 738 738 == 3.4 Set the Probe Model == 739 739 740 740 ... ... @@ -762,7 +762,6 @@ 762 762 * Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 763 763 764 764 765 - 766 766 == 3.5 Multiple collections are one uplink(Since firmware V1.1) == 767 767 768 768 ... ... @@ -794,7 +794,6 @@ 794 794 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 795 795 796 796 797 - 798 798 = 4. Battery & how to replace = 799 799 800 800 == 4.1 Battery Type == ... ... @@ -923,7 +923,6 @@ 923 923 * Weight / pcs : g 924 924 925 925 926 - 927 927 = 10. Support = 928 928 929 929