... ... @@ -58,7 +58,9 @@
58 58  * Uplink on periodically
59 59  * Downlink to change configure
60 60  * 8500mAh Battery for long term use
61 +* Controllable 3.3v,5v and 12v output to power external sensor
61 61  
63 +
62 62  == 1.3 Specification ==
63 63  
64 64  
... ... @@ -105,6 +105,7 @@
105 105  * Sleep Mode: 5uA @ 3.3v
106 106  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
107 107  
110 +
108 108  == 1.4 Probe Types ==
109 109  
110 110  === 1.4.1 Thread Installation Type ===
... ... @@ -123,6 +123,7 @@
123 123  * Operating temperature: -20℃~~60℃
124 124  * Connector Type: Various Types, see order info
125 125  
129 +
126 126  === 1.4.2 Immersion Type ===
127 127  
128 128  
... ... @@ -132,13 +132,11 @@
132 132  * Measuring Range: Measure range can be customized, up to 100m.
133 133  * Accuracy: 0.2% F.S
134 134  * Long-Term Stability: ±0.2% F.S / Year
135 -* Overload 200% F.S
136 -* Zero Temperature Drift: ±2% F.S)
137 -* FS Temperature Drift: ±2% F.S
138 138  * Storage temperature: -30℃~~80℃
139 -* Operating temperature: -40℃~~85℃
140 +* Operating temperature: 0℃~~50
140 140  * Material: 316 stainless steels
141 141  
143 +
142 142  == 1.5 Probe Dimension ==
143 143  
144 144  
... ... @@ -209,6 +209,7 @@
209 209  )))
210 210  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.
211 211  
214 +
212 212  == 1.9 Pin Mapping ==
213 213  
214 214  
... ... @@ -303,18 +303,8 @@
303 303  After join success, it will start to upload messages to TTN and you can see the messages in the panel.
304 304  
305 305  
306 -
307 307  == 2.3 ​Uplink Payload ==
308 308  
309 -
310 -Uplink payloads have two types:
311 -
312 -* Distance Value: Use FPORT=2
313 -* Other control commands: Use other FPORT fields.
314 -
315 -The application server should parse the correct value based on FPORT settings.
316 -
317 -
318 318  === 2.3.1 Device Status, FPORT~=5 ===
319 319  
320 320  
... ... @@ -396,28 +396,14 @@
396 396  |(% style="width:97px" %)(((
397 397  **Size(bytes)**
398 398  )))|(% style="width:48px" %)**2**|(% style="width:71px" %)**2**|(% style="width:98px" %)**2**|(% style="width:73px" %)**2**|(% style="width:122px" %)**1**
399 -|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt  flag>>||anchor="H2.3.7IN126IN226INTpin"]]
392 +|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.5ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.607E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.707E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt  flag>>||anchor="H2.3.8IN126IN226INTpin"]]
400 400  
401 401  [[image:1675144608950-310.png]]
402 402  
403 403  
404 -=== 2.3.3 Sensor value, FPORT~=7 ===
397 +=== 2.3.3 Battery Info ===
405 405  
406 406  
407 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
408 -|(% style="width:94px" %)(((
409 -**Size(bytes)**
410 -)))|(% style="width:43px" %)2|(% style="width:367px" %)n
411 -|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:367px" %)(((
412 -Voltage value, each 2 bytes is a set of voltage values.
413 -)))
414 -
415 -[[image:image-20230220171300-1.png||height="207" width="863"]]
416 -
417 -
418 -=== 2.3.4 Battery Info ===
419 -
420 -
421 421  Check the battery voltage for PS-LB.
422 422  
423 423  Ex1: 0x0B45 = 2885mV
... ... @@ -425,26 +425,27 @@
425 425  Ex2: 0x0B49 = 2889mV
426 426  
427 427  
428 -=== 2.3.5 Probe Model ===
407 +=== 2.3.4 Probe Model ===
429 429  
430 430  
431 -PS-LB has different kind of probe, 0~~20mA represent the full scale of the measuring range. So a 15mA output means different meaning for different probe. 
410 +PS-LB has different kind of probe, 4~~20mA represent the full scale of the measuring range. So a 12mA output means different meaning for different probe. 
432 432  
433 433  
434 434  For example.
435 435  
436 436  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
437 -|(% style="width:111px" %)**Part Number**|(% style="width:158px" %)**Probe Used**|**0~~20mA scale**|**Example: 10mA meaning**
438 -|(% style="width:111px" %)PS-LB-I3|(% style="width:158px" %)immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
439 -|(% style="width:111px" %)PS-LB-I5|(% style="width:158px" %)immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
416 +|**Part Number**|**Probe Used**|**4~~20mA scale**|**Example: 12mA meaning**
417 +|PS-LB-I3|immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
418 +|PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
419 +|PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure
440 440  
441 -The probe model field provides the convenient for server to identical how it should parse the 0~~20mA sensor value and get the correct value.
421 +The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value.
442 442  
443 443  
444 -=== 2.3.6 0~~20mA value (IDC_IN) ===
424 +=== 2.3.5 0~~20mA value (IDC_IN) ===
445 445  
446 446  
447 -The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level.
427 +The output value from **Pressure Probe**, use together with Probe Model to get the pressure value or water level.
448 448  
449 449  (% style="color:#037691" %)**Example**:
450 450  
... ... @@ -451,9 +451,14 @@
451 451  27AE(H) = 10158 (D)/1000 = 10.158mA.
452 452  
453 453  
454 -=== 2.3.7 0~~30V value ( pin VDC_IN) ===
434 +Instead of pressure probe, User can also connect a general 4~~20mA in this port to support different types of 4~~20mA sensors. below is the connection example:
455 455  
436 +[[image:image-20230225154759-1.png||height="408" width="741"]]
456 456  
438 +
439 +=== 2.3.6 0~~30V value ( pin VDC_IN) ===
440 +
441 +
457 457  Measure the voltage value. The range is 0 to 30V.
458 458  
459 459  (% style="color:#037691" %)**Example**:
... ... @@ -461,7 +461,7 @@
461 461  138E(H) = 5006(D)/1000= 5.006V
462 462  
463 463  
464 -=== 2.3.8 IN1&IN2&INT pin ===
449 +=== 2.3.7 IN1&IN2&INT pin ===
465 465  
466 466  
467 467  IN1 and IN2 are used as digital input pins.
... ... @@ -484,6 +484,24 @@
484 484  0x01: Interrupt Uplink Packet.
485 485  
486 486  
472 +=== (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 ===
473 +
474 +
475 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
476 +|(% style="width:94px" %)(((
477 +**Size(bytes)**
478 +)))|(% style="width:43px" %)2|(% style="width:367px" %)n
479 +|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)(((
480 +Voltage value, each 2 bytes is a set of voltage values.
481 +)))
482 +
483 +[[image:image-20230220171300-1.png||height="207" width="863"]]
484 +
485 +Multiple sets of data collected are displayed in this form:
486 +
487 +[voltage value1], [voltage value2], [voltage value3],…[voltage value n/2]
488 +
489 +
487 487  === 2.3.9 ​Decode payload in The Things Network ===
488 488  
489 489  
... ... @@ -564,7 +564,6 @@
564 564  [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]
565 565  
566 566  
567 -
568 568  = 3. Configure PS-LB via AT Command or LoRaWAN Downlink =
569 569  
570 570  
... ... @@ -620,6 +620,7 @@
620 620  * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
621 621  * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
622 622  
625 +
623 623  == 3.2 Set Interrupt Mode ==
624 624  
625 625  
... ... @@ -632,14 +632,14 @@
632 632  |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
633 633  0
634 634  OK
635 -the mode is 0 = No interruption
638 +the mode is 0 =Disable Interrupt
636 636  )))
637 637  |(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
638 638  Set Transmit Interval
639 -~1. (Disable Interrupt),
640 -2. (Trigger by rising and falling edge)
641 -3. (Trigger by falling edge)
642 -4. (Trigger by rising edge)
642 +0. (Disable Interrupt),
643 +~1. (Trigger by rising and falling edge)
644 +2. (Trigger by falling edge)
645 +3. (Trigger by rising edge)
643 643  )))|(% style="width:157px" %)OK
644 644  
645 645  (% style="color:blue" %)**Downlink Command: 0x06**
... ... @@ -651,6 +651,7 @@
651 651  * Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
652 652  * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
653 653  
657 +
654 654  == 3.3 Set the output time ==
655 655  
656 656  
... ... @@ -720,32 +720,45 @@
720 720  * Example 5: Downlink Payload: 070301F4  **~-~-->**  AT+12VT=500
721 721  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
722 722  
727 +
723 723  == 3.4 Set the Probe Model ==
724 724  
725 725  
726 -(% style="color:blue" %)**AT Command: AT** **+PROBE**
731 +Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value.
727 727  
728 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:448px" %)
729 -|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 204px;" %)**Function**|=(% style="width: 85px;" %)**Response**
730 -|(% style="width:154px" %)AT +PROBE =?|(% style="width:204px" %)Get or Set the probe model.|(% style="width:85px" %)(((
731 -0
733 +**AT Command: AT** **+PROBE**
734 +
735 +AT+PROBE=aabb
736 +
737 +When aa=00, it is the water depth mode, and the current is converted into the water depth value; bb is the probe at a depth of several meters.
738 +
739 +When aa=01, it is the pressure mode, which converts the current into a pressure value;
740 +
741 +bb represents which type of pressure sensor it is.
742 +
743 +(A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C)
744 +
745 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
746 +|**Command Example**|**Function**|**Response**
747 +|AT +PROBE =?|Get or Set the probe model.|0
732 732  OK
733 -)))
734 -|(% style="width:154px" %)AT +PROBE =0003|(% style="width:204px" %)Set water depth sensor mode, 3m type.|(% style="width:85px" %)OK
735 -|(% style="width:154px" %)AT +PROBE =0101|(% style="width:204px" %)Set pressure transmitters mode, first type.|(% style="width:85px" %)(((
736 -OK
737 -)))
738 -|(% style="width:154px" %)AT +PROBE =0000|(% style="width:204px" %)Initial state, no settings.|(% style="width:85px" %)(((
739 -OK
740 -)))
749 +|AT +PROBE =0003|Set water depth sensor mode, 3m type.|OK
750 +|(((
751 +AT +PROBE =000A
741 741  
742 -(% style="color:blue" %)**Downlink Command: 0x08**
753 +
754 +)))|Set water depth sensor mode, 10m type.|OK
755 +|AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK
756 +|AT +PROBE =0000|Initial state, no settings.|OK
743 743  
758 +**Downlink Command: 0x08**
759 +
744 744  Format: Command Code (0x08) followed by 2 bytes.
745 745  
746 -* Example 1: Downlink Payload: 080003  **~-~-->**  AT+PROBE=0003
747 -* Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
762 +* Example 1: Downlink Payload: 080003  **~-~-->**  AT+PROBE=0003
763 +* Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
748 748  
765 +
749 749  == 3.5 Multiple collections are one uplink(Since firmware V1.1) ==
750 750  
751 751  
... ... @@ -753,21 +753,31 @@
753 753  
754 754  (% style="color:blue" %)**AT Command: AT** **+STDC**
755 755  
773 +AT+STDC=aa,bb,bb
774 +
775 +(% style="color:#037691" %)**aa:**(%%)
776 +**0:** means disable this function and use TDC to send packets.
777 +**1:** means enable this function, use the method of multiple acquisitions to send packets.
778 +(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
779 +(% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120
780 +
756 756  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
757 -|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response**
758 -|(% style="width:156px" %)AT+STDC=?|(% style="width:137px" %)(((
759 -Get the mode of multiple acquisitions and one uplink
760 -)))|(((
761 -1,10,18
782 +|**Command Example**|**Function**|**Response**
783 +|AT+STDC=?|Get the mode of multiple acquisitions and one uplink.|1,10,18
762 762  OK
785 +|AT+STDC=1,10,18|Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|(((
786 +Attention:Take effect after ATZ
787 +
788 +OK
763 763  )))
764 -|(% style="width:156px" %)AT+STDC=1,10,18|(% style="width:137px" %)Set the mode of multiple acquisitions and one uplink|(((
790 +|AT+STDC=0, 0,0|(((
791 +Use the TDC interval to send packets.(default)
792 +
793 +
794 +)))|(((
795 +Attention:Take effect after ATZ
796 +
765 765  OK
766 -**(% style="color:#037691" %)aa:**(%%)
767 -**0** means disable this function and use TDC to send packets.
768 -**1** means enable this function, use the method of multiple acquisitions to send packets.
769 -**(% style="color:#037691" %)bb:**(%%) Each collection interval (s), the value is 1~~65535
770 -**(% style="color:#037691" %)cc:**(%%)the number of collection times, the value is 1~~120
771 771  )))
772 772  
773 773  (% style="color:blue" %)**Downlink Command: 0xAE**
... ... @@ -776,6 +776,7 @@
776 776  
777 777  * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->**  AT+STDC=1,600,18
778 778  
806 +
779 779  = 4. Battery & how to replace =
780 780  
781 781  == 4.1 Battery Type ==
... ... @@ -903,6 +903,7 @@
903 903  * Package Size / pcs : cm
904 904  * Weight / pcs : g
905 905  
934 +
906 906  = 10. Support =
907 907  
908 908  
image-20230222174559-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +19.4 KB
Content
image-20230225154759-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +468.9 KB
Content