Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/03 14:00
Change comment:
Uploaded new attachment "image-20230220171300-1.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -59,6 +59,8 @@ 59 59 * Downlink to change configure 60 60 * 8500mAh Battery for long term use 61 61 62 + 63 + 62 62 == 1.3 Specification == 63 63 64 64 ... ... @@ -105,6 +105,8 @@ 105 105 * Sleep Mode: 5uA @ 3.3v 106 106 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 107 107 110 + 111 + 108 108 == 1.4 Probe Types == 109 109 110 110 === 1.4.1 Thread Installation Type === ... ... @@ -123,6 +123,8 @@ 123 123 * Operating temperature: -20℃~~60℃ 124 124 * Connector Type: Various Types, see order info 125 125 130 + 131 + 126 126 === 1.4.2 Immersion Type === 127 127 128 128 ... ... @@ -139,6 +139,8 @@ 139 139 * Operating temperature: -40℃~~85℃ 140 140 * Material: 316 stainless steels 141 141 148 + 149 + 142 142 == 1.5 Probe Dimension == 143 143 144 144 ... ... @@ -209,6 +209,8 @@ 209 209 ))) 210 210 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 211 211 220 + 221 + 212 212 == 1.9 Pin Mapping == 213 213 214 214 ... ... @@ -401,23 +401,9 @@ 401 401 [[image:1675144608950-310.png]] 402 402 403 403 404 -=== 2.3.3 Sensorvalue,FPORT~=7===414 +=== 2.3.3 Battery Info === 405 405 406 406 407 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %) 408 -|(% style="width:94px" %)((( 409 -**Size(bytes)** 410 -)))|(% style="width:43px" %)2|(% style="width:367px" %)n 411 -|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:367px" %)((( 412 -Voltage value, each 2 bytes is a set of voltage values. 413 -))) 414 - 415 -[[image:image-20230220171300-1.png||height="207" width="863"]] 416 - 417 - 418 -=== 2.3.4 Battery Info === 419 - 420 - 421 421 Check the battery voltage for PS-LB. 422 422 423 423 Ex1: 0x0B45 = 2885mV ... ... @@ -425,7 +425,7 @@ 425 425 Ex2: 0x0B49 = 2889mV 426 426 427 427 428 -=== 2.3. 5Probe Model ===424 +=== 2.3.4 Probe Model === 429 429 430 430 431 431 PS-LB has different kind of probe, 0~~20mA represent the full scale of the measuring range. So a 15mA output means different meaning for different probe. ... ... @@ -441,7 +441,7 @@ 441 441 The probe model field provides the convenient for server to identical how it should parse the 0~~20mA sensor value and get the correct value. 442 442 443 443 444 -=== 2.3. 60~~20mA value (IDC_IN) ===440 +=== 2.3.5 0~~20mA value (IDC_IN) === 445 445 446 446 447 447 The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level. ... ... @@ -451,7 +451,7 @@ 451 451 27AE(H) = 10158 (D)/1000 = 10.158mA. 452 452 453 453 454 -=== 2.3. 70~~30V value ( pin VDC_IN) ===450 +=== 2.3.6 0~~30V value ( pin VDC_IN) === 455 455 456 456 457 457 Measure the voltage value. The range is 0 to 30V. ... ... @@ -461,7 +461,7 @@ 461 461 138E(H) = 5006(D)/1000= 5.006V 462 462 463 463 464 -=== 2.3. 8IN1&IN2&INT pin ===460 +=== 2.3.7 IN1&IN2&INT pin === 465 465 466 466 467 467 IN1 and IN2 are used as digital input pins. ... ... @@ -484,7 +484,7 @@ 484 484 0x01: Interrupt Uplink Packet. 485 485 486 486 487 -=== 2.3. 9Decode payload in The Things Network ===483 +=== 2.3.8 Decode payload in The Things Network === 488 488 489 489 490 490 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -620,6 +620,8 @@ 620 620 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 621 621 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 622 622 619 + 620 + 623 623 == 3.2 Set Interrupt Mode == 624 624 625 625 ... ... @@ -651,6 +651,8 @@ 651 651 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 652 652 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 653 653 652 + 653 + 654 654 == 3.3 Set the output time == 655 655 656 656 ... ... @@ -675,6 +675,7 @@ 675 675 OK 676 676 ))) 677 677 678 + 678 678 (% style="color:blue" %)**AT Command: AT+5VT** 679 679 680 680 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:470px" %) ... ... @@ -694,6 +694,7 @@ 694 694 OK 695 695 ))) 696 696 698 + 697 697 (% style="color:blue" %)**AT Command: AT+12VT** 698 698 699 699 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:443px" %) ... ... @@ -707,6 +707,7 @@ 707 707 OK 708 708 ))) 709 709 712 + 710 710 (% style="color:blue" %)**Downlink Command: 0x07** 711 711 712 712 Format: Command Code (0x07) followed by 3 bytes. ... ... @@ -720,6 +720,8 @@ 720 720 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 721 721 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 722 722 726 + 727 + 723 723 == 3.4 Set the Probe Model == 724 724 725 725 ... ... @@ -746,36 +746,8 @@ 746 746 * Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 747 747 * Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 748 748 749 -== 3.5 Multiple collections are one uplink(Since firmware V1.1) == 750 750 751 751 752 -Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. 753 - 754 -(% style="color:blue" %)**AT Command: AT** **+STDC** 755 - 756 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 757 -|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response** 758 -|(% style="width:156px" %)AT+STDC=?|(% style="width:137px" %)((( 759 -Get the mode of multiple acquisitions and one uplink 760 -)))|((( 761 -1,10,18 762 -OK 763 -))) 764 -|(% style="width:156px" %)AT+STDC=1,10,18|(% style="width:137px" %)Set the mode of multiple acquisitions and one uplink|((( 765 -OK 766 -aa: 767 -0 means disable this function and use TDC to send packets. 768 -1 means enable this function, use the method of multiple acquisitions to send packets. 769 -bb: Each collection interval (s), the value is 1~~65535 770 -cc: the number of collection times, the value is 1~~120 771 -))) 772 - 773 -(% style="color:blue" %)**Downlink Command: 0xAE** 774 - 775 -Format: Command Code (0x08) followed by 5 bytes. 776 - 777 -* Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 778 - 779 779 = 4. Battery & how to replace = 780 780 781 781 == 4.1 Battery Type == ... ... @@ -903,6 +903,8 @@ 903 903 * Package Size / pcs : cm 904 904 * Weight / pcs : g 905 905 883 + 884 + 906 906 = 10. Support = 907 907 908 908 ... ... @@ -910,4 +910,6 @@ 910 910 911 911 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 912 912 892 + 893 + 913 913