Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 09:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -243,6 +243,8 @@ 243 243 == 1.11 Mechanical == 244 244 245 245 246 + 247 + 246 246 [[image:1675143884058-338.png]] 247 247 248 248 ... ... @@ -411,6 +411,7 @@ 411 411 [[image:1675144608950-310.png]] 412 412 413 413 416 + 414 414 === 2.3.3 Battery Info === 415 415 416 416 ... ... @@ -607,14 +607,15 @@ 607 607 Set transmit interval to 60000ms = 60 seconds 608 608 ))) 609 609 613 + 610 610 (% style="color:blue" %)**Downlink Command: 0x01** 611 611 612 612 Format: Command Code (0x01) followed by 3 bytes time value. 613 613 614 -If the downlink payload=0100003C, it means set the END Node 's Transmit Interval to 0x00003C=60(S), while type code is 01.618 +If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01. 615 615 616 -* Example 1: Downlink Payload: 0100001E 617 -* Example 2: Downlink Payload: 0100003C 620 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 621 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 618 618 619 619 620 620 ... ... @@ -626,20 +626,21 @@ 626 626 (% style="color:blue" %)**AT Command: AT+INTMOD** 627 627 628 628 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 629 -|= (% style="width: 154px;" %)**Command Example**|=(% style="width: 196px;" %)**Function**|=(% style="width: 157px;" %)**Response**630 -| (% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((633 +|=**Command Example**|=**Function**|=**Response** 634 +|AT+INTMOD=?|Show current interrupt mode|((( 631 631 0 632 632 OK 633 633 the mode is 0 = No interruption 634 634 ))) 635 -| (% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((639 +|AT+INTMOD=2|((( 636 636 Set Transmit Interval 637 637 ~1. (Disable Interrupt), 638 638 2. (Trigger by rising and falling edge) 639 639 3. (Trigger by falling edge) 640 640 4. (Trigger by rising edge) 641 -)))| (% style="width:157px" %)OK645 +)))|OK 642 642 647 + 643 643 (% style="color:blue" %)**Downlink Command: 0x06** 644 644 645 645 Format: Command Code (0x06) followed by 3 bytes. ... ... @@ -646,8 +646,8 @@ 646 646 647 647 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 648 648 649 -* Example 1: Downlink Payload: 06000000 650 -* Example 2: Downlink Payload: 06000003 654 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 655 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 651 651 652 652 653 653 ... ... @@ -744,6 +744,7 @@ 744 744 OK 745 745 ))) 746 746 752 + 747 747 (% style="color:blue" %)**Downlink Command: 0x08** 748 748 749 749 Format: Command Code (0x08) followed by 2 bytes. ... ... @@ -760,6 +760,7 @@ 760 760 761 761 PS-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 762 762 769 + 763 763 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 764 764 765 765 [[image:1675146710956-626.png]] ... ... @@ -891,4 +891,5 @@ 891 891 892 892 893 893 901 + 894 894
- image-20230201090514-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -560.9 KB - Content