Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Mengting Qiu on 2025/07/08 10:59
From version 43.2
edited by Xiaoling
on 2023/02/01 11:33
on 2023/02/01 11:33
Change comment:
There is no comment for this version
To version 53.1
edited by Edwin Chen
on 2023/04/01 21:15
on 2023/04/01 21:15
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -58,6 +58,7 @@ 58 58 * Uplink on periodically 59 59 * Downlink to change configure 60 60 * 8500mAh Battery for long term use 61 +* Controllable 3.3v,5v and 12v output to power external sensor 61 61 62 62 63 63 == 1.3 Specification == ... ... @@ -135,11 +135,8 @@ 135 135 * Measuring Range: Measure range can be customized, up to 100m. 136 136 * Accuracy: 0.2% F.S 137 137 * Long-Term Stability: ±0.2% F.S / Year 138 -* Overload 200% F.S 139 -* Zero Temperature Drift: ±2% F.S) 140 -* FS Temperature Drift: ±2% F.S 141 141 * Storage temperature: -30℃~~80℃ 142 -* Operating temperature: -40℃~~85℃140 +* Operating temperature: 0℃~~50℃ 143 143 * Material: 316 stainless steels 144 144 145 145 ... ... @@ -238,8 +238,6 @@ 238 238 == 1.11 Mechanical == 239 239 240 240 241 - 242 - 243 243 [[image:1675143884058-338.png]] 244 244 245 245 ... ... @@ -310,18 +310,8 @@ 310 310 After join success, it will start to upload messages to TTN and you can see the messages in the panel. 311 311 312 312 313 - 314 314 == 2.3 Uplink Payload == 315 315 316 - 317 -Uplink payloads have two types: 318 - 319 -* Distance Value: Use FPORT=2 320 -* Other control commands: Use other FPORT fields. 321 - 322 -The application server should parse the correct value based on FPORT settings. 323 - 324 - 325 325 === 2.3.1 Device Status, FPORT~=5 === 326 326 327 327 ... ... @@ -403,12 +403,11 @@ 403 403 |(% style="width:97px" %)((( 404 404 **Size(bytes)** 405 405 )))|(% style="width:48px" %)**2**|(% style="width:71px" %)**2**|(% style="width:98px" %)**2**|(% style="width:73px" %)**2**|(% style="width:122px" %)**1** 406 -|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3. 3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.7IN126IN226INTpin"]]392 +|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.5ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.607E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.707E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.8IN126IN226INTpin"]] 407 407 408 408 [[image:1675144608950-310.png]] 409 409 410 410 411 - 412 412 === 2.3.3 Battery Info === 413 413 414 414 ... ... @@ -422,23 +422,24 @@ 422 422 === 2.3.4 Probe Model === 423 423 424 424 425 -PS-LB has different kind of probe, 0~~20mA represent the full scale of the measuring range. So a 15mA output means different meaning for different probe.410 +PS-LB has different kind of probe, 4~~20mA represent the full scale of the measuring range. So a 12mA output means different meaning for different probe. 426 426 427 427 428 428 For example. 429 429 430 430 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 431 -|(% style="width:111px" %)**Part Number**|(% style="width:158px" %)**Probe Used**|**0~~20mA scale**|**Example: 10mA meaning** 432 -|(% style="width:111px" %)PS-LB-I3|(% style="width:158px" %)immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water 433 -|(% style="width:111px" %)PS-LB-I5|(% style="width:158px" %)immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 416 +|**Part Number**|**Probe Used**|**4~~20mA scale**|**Example: 12mA meaning** 417 +|PS-LB-I3|immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water 418 +|PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 419 +|PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure 434 434 435 -The probe model field provides the convenient for server to identical how it should parse the 0~~20mA sensor value and get the correct value.421 +The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value. 436 436 437 437 438 438 === 2.3.5 0~~20mA value (IDC_IN) === 439 439 440 440 441 -The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level. 427 +The output value from **Pressure Probe**, use together with Probe Model to get the pressure value or water level. 442 442 443 443 (% style="color:#037691" %)**Example**: 444 444 ... ... @@ -445,6 +445,11 @@ 445 445 27AE(H) = 10158 (D)/1000 = 10.158mA. 446 446 447 447 434 +Instead of pressure probe, User can also connect a general 4~~20mA in this port to support different types of 4~~20mA sensors. below is the connection example: 435 + 436 +[[image:image-20230225154759-1.png||height="408" width="741"]] 437 + 438 + 448 448 === 2.3.6 0~~30V value ( pin VDC_IN) === 449 449 450 450 ... ... @@ -478,9 +478,27 @@ 478 478 0x01: Interrupt Uplink Packet. 479 479 480 480 481 -=== 2.3.8DecodepayloadTheThingsNetwork===472 +=== (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 === 482 482 483 483 475 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %) 476 +|(% style="width:94px" %)((( 477 +**Size(bytes)** 478 +)))|(% style="width:43px" %)2|(% style="width:367px" %)n 479 +|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)((( 480 +Voltage value, each 2 bytes is a set of voltage values. 481 +))) 482 + 483 +[[image:image-20230220171300-1.png||height="207" width="863"]] 484 + 485 +Multiple sets of data collected are displayed in this form: 486 + 487 +[voltage value1], [voltage value2], [voltage value3],…[voltage value n/2] 488 + 489 + 490 +=== 2.3.9 Decode payload in The Things Network === 491 + 492 + 484 484 While using TTN network, you can add the payload format to decode the payload. 485 485 486 486 ... ... @@ -558,35 +558,36 @@ 558 558 [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]] 559 559 560 560 570 += 3. Configure PS-LB = 561 561 562 -= 3. Configure PS-LB via AT Commandor LoRaWAN Downlink=572 +== 3.1 Configure Methods == 563 563 574 +PS-LB-NA supports below configure method: 564 564 565 -Use can configure PS-LB via AT Command or LoRaWAN Downlink. 576 +* AT Command via Bluetooth Connection (**Recommand Way**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 577 +* AT Command via UART Connection : See [[FAQ>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/#H7.FAQ]]. 578 +* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 566 566 567 -* AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]]. 568 -* LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 569 569 570 - Therearetwokinds of commandsto configure PS-LB, they are:581 +== 3.2 General Commands == 571 571 572 -* (% style="color:#037691" %)**General Commands** 573 - 574 574 These commands are to configure: 575 575 576 576 * General system settings like: uplink interval. 577 577 * LoRaWAN protocol & radio related command. 578 578 579 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 588 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 580 580 581 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 590 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 582 582 583 583 584 -* (% style="color:#037691" %)**Commands special design for PS-LB** 585 585 594 +== 3.3 Commands special design for PS-LB == 595 + 586 586 These commands only valid for PS-LB, as below: 587 587 588 588 589 -== 3.1 Set Transmit Interval Time == 599 +=== 3.3.1 Set Transmit Interval Time === 590 590 591 591 592 592 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -615,7 +615,7 @@ 615 615 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 616 616 617 617 618 -== 3.2 Set Interrupt Mode == 628 +=== 3.3.2 Set Interrupt Mode === 619 619 620 620 621 621 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -627,14 +627,14 @@ 627 627 |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 628 628 0 629 629 OK 630 -the mode is 0 = Nointerruption640 +the mode is 0 =Disable Interrupt 631 631 ))) 632 632 |(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 633 633 Set Transmit Interval 634 - ~1. (Disable Interrupt),635 - 2. (Trigger by rising and falling edge)636 - 3. (Trigger by falling edge)637 - 4. (Trigger by rising edge)644 +0. (Disable Interrupt), 645 +~1. (Trigger by rising and falling edge) 646 +2. (Trigger by falling edge) 647 +3. (Trigger by rising edge) 638 638 )))|(% style="width:157px" %)OK 639 639 640 640 (% style="color:blue" %)**Downlink Command: 0x06** ... ... @@ -647,7 +647,7 @@ 647 647 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 648 648 649 649 650 -== 3.3 Set the output time == 660 +=== 3.3.3 Set the output time === 651 651 652 652 653 653 Feature, Control the output 3V3 , 5V or 12V. ... ... @@ -717,135 +717,113 @@ 717 717 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 718 718 719 719 720 -== 3.4 Set the Probe Model == 730 +=== 3.3.4 Set the Probe Model === 721 721 722 722 723 - (%style="color:blue"%)**ATCommand:AT****+PROBE**733 +Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value. 724 724 725 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:448px" %) 726 -|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 204px;" %)**Function**|=(% style="width: 85px;" %)**Response** 727 -|(% style="width:154px" %)AT +PROBE =?|(% style="width:204px" %)Get or Set the probe model.|(% style="width:85px" %)((( 728 -0 729 -OK 730 -))) 731 -|(% style="width:154px" %)AT +PROBE =0003|(% style="width:204px" %)Set water depth sensor mode, 3m type.|(% style="width:85px" %)OK 732 -|(% style="width:154px" %)AT +PROBE =0101|(% style="width:204px" %)Set pressure transmitters mode, first type.|(% style="width:85px" %)((( 733 -OK 734 -))) 735 -|(% style="width:154px" %)AT +PROBE =0000|(% style="width:204px" %)Initial state, no settings.|(% style="width:85px" %)((( 736 -OK 737 -))) 735 +**AT Command: AT** **+PROBE** 738 738 739 - (% style="color:blue" %)**Downlink Command: 0x08**737 +AT+PROBE=aabb 740 740 741 - Format:CommandCode(0x08)followed by2bytes.739 +When aa=00, it is the water depth mode, and the current is converted into the water depth value; bb is the probe at a depth of several meters. 742 742 743 -* Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 744 -* Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 741 +When aa=01, it is the pressure mode, which converts the current into a pressure value; 745 745 743 +bb represents which type of pressure sensor it is. 746 746 747 - =4.Battery & how to replace =745 +(A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C) 748 748 749 -== 4.1 Battery Type == 747 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 748 +|**Command Example**|**Function**|**Response** 749 +|AT +PROBE =?|Get or Set the probe model.|0 750 +OK 751 +|AT +PROBE =0003|Set water depth sensor mode, 3m type.|OK 752 +|((( 753 +AT +PROBE =000A 750 750 755 + 756 +)))|Set water depth sensor mode, 10m type.|OK 757 +|AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK 758 +|AT +PROBE =0000|Initial state, no settings.|OK 751 751 752 - PS-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targetingfor 8~~10 years use. This type of battery is commonly usedin IoT target for long-term running, such as water meter.760 +**Downlink Command: 0x08** 753 753 762 +Format: Command Code (0x08) followed by 2 bytes. 754 754 755 -The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 764 +* Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 765 +* Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 756 756 757 -[[image:1675146710956-626.png]] 758 758 768 +=== 3.3.5 Multiple collections are one uplink(Since firmware V1.1) === 759 759 760 -Minimum Working Voltage for the PS-LB: 761 761 762 - PS-LB:2.45v~~3.6v771 +Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. 763 763 773 +(% style="color:blue" %)**AT Command: AT** **+STDC** 764 764 765 -= = 4.2 Replace Battery ==775 +AT+STDC=aa,bb,bb 766 766 777 +(% style="color:#037691" %)**aa:**(%%) 778 +**0:** means disable this function and use TDC to send packets. 779 +**1:** means enable this function, use the method of multiple acquisitions to send packets. 780 +(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535 781 +(% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120 767 767 768 -Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 783 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 784 +|**Command Example**|**Function**|**Response** 785 +|AT+STDC=?|Get the mode of multiple acquisitions and one uplink.|1,10,18 786 +OK 787 +|AT+STDC=1,10,18|Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|((( 788 +Attention:Take effect after ATZ 769 769 770 -And make sure the positive and negative pins match. 790 +OK 791 +))) 792 +|AT+STDC=0, 0,0|((( 793 +Use the TDC interval to send packets.(default) 771 771 795 + 796 +)))|((( 797 +Attention:Take effect after ATZ 772 772 773 -== 4.3 Power Consumption Analyze == 799 +OK 800 +))) 774 774 802 +(% style="color:blue" %)**Downlink Command: 0xAE** 775 775 776 - DraginoBattery powered product are all runs in Low Powermode. We have an updatebattery calculator which base on themeasurementof the realdevice.Usercan use this calculator to checkthebatterylifeand calculate thebatterylife if wantto usedifferent transmit interval.804 +Format: Command Code (0x08) followed by 5 bytes. 777 777 778 - Instructionto useas below:806 +* Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 779 779 780 -(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]] 781 781 782 - (%style="color:blue"%)**Step2:**(%%) Openitandchoose809 += 4. Battery & Power Consumption = 783 783 784 -* Product Model 785 -* Uplink Interval 786 -* Working Mode 811 +PS-LB-NA uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 787 787 788 - AndtheLifeexpectationindifference casewillbeshownntheht.813 + [[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 789 789 790 -[[image:1675146895108-304.png]] 791 791 816 += 5. OTA firmware update = 792 792 793 -The battery related documents as below: 794 794 795 -* [[Battery Dimension>>https://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]], 796 -* [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]] 797 -* [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]] 798 - 799 -[[image:image-20230131145708-3.png]] 800 - 801 - 802 -=== 4.3.1 Battery Note === 803 - 804 - 805 -The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 806 - 807 - 808 -=== 4.3.2 Replace the battery === 809 - 810 - 811 -You can change the battery in the PS-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 812 - 813 -The default battery pack of PS-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 814 - 815 - 816 -= 5. Remote Configure device = 817 - 818 -== 5.1 Connect via BLE == 819 - 820 - 821 -Please see this instruction for how to configure via BLE: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]] 822 - 823 - 824 -== 5.2 AT Command Set == 825 - 826 - 827 - 828 -= 6. OTA firmware update = 829 - 830 - 831 831 Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 832 832 833 833 834 -= 7. FAQ =822 += 6. FAQ = 835 835 836 -== 7.1 How to use AT Command to access device? ==824 +== 6.1 How to use AT Command via UART to access device? == 837 837 838 838 839 839 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 840 840 841 841 842 -== 7.2 How to update firmware via UART port? ==830 +== 6.2 How to update firmware via UART port? == 843 843 844 844 845 845 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 846 846 847 847 848 -== 7.3 How to change the LoRa Frequency Bands/Region? ==836 +== 6.3 How to change the LoRa Frequency Bands/Region? == 849 849 850 850 851 851 You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]. ... ... @@ -852,13 +852,13 @@ 852 852 When downloading the images, choose the required image file for download. 853 853 854 854 855 -= 8. Order Info =843 += 7. Order Info = 856 856 857 857 858 858 [[image:image-20230131153105-4.png]] 859 859 860 860 861 -= 9. Packing Info =849 += 8. Packing Info = 862 862 863 863 864 864 (% style="color:#037691" %)**Package Includes**: ... ... @@ -873,7 +873,7 @@ 873 873 * Weight / pcs : g 874 874 875 875 876 -= 10. Support =864 += 9. Support = 877 877 878 878 879 879 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. ... ... @@ -880,6 +880,4 @@ 880 880 881 881 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 882 882 883 - 884 - 885 885
- image-20230220171300-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +98.0 KB - Content
- image-20230222174559-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.4 KB - Content
- image-20230225154759-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +468.9 KB - Content