Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/03 14:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -243,8 +243,6 @@ 243 243 == 1.11 Mechanical == 244 244 245 245 246 - 247 - 248 248 [[image:1675143884058-338.png]] 249 249 250 250 ... ... @@ -413,7 +413,6 @@ 413 413 [[image:1675144608950-310.png]] 414 414 415 415 416 - 417 417 === 2.3.3 Battery Info === 418 418 419 419 ... ... @@ -610,15 +610,14 @@ 610 610 Set transmit interval to 60000ms = 60 seconds 611 611 ))) 612 612 613 - 614 614 (% style="color:blue" %)**Downlink Command: 0x01** 615 615 616 616 Format: Command Code (0x01) followed by 3 bytes time value. 617 617 618 -If the downlink payload=0100003C, it means set the END Node ’s Transmit Interval to 0x00003C=60(S), while type code is 01.614 +If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. 619 619 620 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 621 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 616 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 617 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 622 622 623 623 624 624 ... ... @@ -630,21 +630,20 @@ 630 630 (% style="color:blue" %)**AT Command: AT+INTMOD** 631 631 632 632 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 633 -|=**Command Example**|=**Function**|=**Response** 634 -|AT+INTMOD=?|Show current interrupt mode|((( 629 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 196px;" %)**Function**|=(% style="width: 157px;" %)**Response** 630 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 635 635 0 636 636 OK 637 637 the mode is 0 = No interruption 638 638 ))) 639 -|AT+INTMOD=2|((( 635 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 640 640 Set Transmit Interval 641 641 ~1. (Disable Interrupt), 642 642 2. (Trigger by rising and falling edge) 643 643 3. (Trigger by falling edge) 644 644 4. (Trigger by rising edge) 645 -)))|OK 641 +)))|(% style="width:157px" %)OK 646 646 647 - 648 648 (% style="color:blue" %)**Downlink Command: 0x06** 649 649 650 650 Format: Command Code (0x06) followed by 3 bytes. ... ... @@ -651,8 +651,8 @@ 651 651 652 652 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 653 653 654 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 655 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 649 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 650 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 656 656 657 657 658 658 ... ... @@ -749,7 +749,6 @@ 749 749 OK 750 750 ))) 751 751 752 - 753 753 (% style="color:blue" %)**Downlink Command: 0x08** 754 754 755 755 Format: Command Code (0x08) followed by 2 bytes. ... ... @@ -766,7 +766,6 @@ 766 766 767 767 PS-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 768 768 769 - 770 770 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 771 771 772 772 [[image:1675146710956-626.png]] ... ... @@ -898,5 +898,4 @@ 898 898 899 899 900 900 901 - 902 902