Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/03 14:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -300,7 +300,7 @@ 300 300 301 301 Press the button for 5 seconds to activate the PS-LB. 302 302 303 -**Green led** will fast blink 5 times, device will enter **OTA mode** for 3 seconds. And then start to JOIN LoRaWAN network. **Green led** will solidly turn on for 5 seconds after joined in network. 303 +**(% style="color:green" %)Green led**(%%) will fast blink 5 times, device will enter **(% style="color:blue" %)OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. **(% style="color:green" %)Green led**(%%) will solidly turn on for 5 seconds after joined in network. 304 304 305 305 After join success, it will start to upload messages to TTN and you can see the messages in the panel. 306 306 ... ... @@ -335,11 +335,11 @@ 335 335 [[image:1675144504430-490.png]] 336 336 337 337 338 -**Sensor Model**: For PS-LB, this value is 0x16 338 +**(% style="color:#037691" %)Sensor Model**(%%): For PS-LB, this value is 0x16 339 339 340 -**Firmware Version**: 0x0100, Means: v1.0.0 version 340 +**(% style="color:#037691" %)Firmware Version**(%%): 0x0100, Means: v1.0.0 version 341 341 342 -**Frequency Band**: 342 +**(% style="color:#037691" %)Frequency Band**: 343 343 344 344 *0x01: EU868 345 345 ... ... @@ -370,7 +370,7 @@ 370 370 *0x0e: MA869 371 371 372 372 373 -**Sub-Band**: 373 +**(% style="color:#037691" %)Sub-Band**: 374 374 375 375 AU915 and US915:value 0x00 ~~ 0x08 376 376 ... ... @@ -379,7 +379,7 @@ 379 379 Other Bands: Always 0x00 380 380 381 381 382 -**Battery Info**: 382 +**(% style="color:#037691" %)Battery Info**: 383 383 384 384 Check the battery voltage. 385 385 ... ... @@ -388,7 +388,7 @@ 388 388 Ex2: 0x0B49 = 2889mV 389 389 390 390 391 -=== 1.3.2 Sensor value, FPORT~=2 ===391 +=== 2.3.2 Sensor value, FPORT~=2 === 392 392 393 393 394 394 Uplink payload includes in total 9 bytes. ... ... @@ -435,7 +435,7 @@ 435 435 436 436 The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level. 437 437 438 -**Example**: 438 +**(% style="color:#037691" %)Example**: 439 439 440 440 27AE(H) = 10158 (D)/1000 = 10.158mA. 441 441 ... ... @@ -445,7 +445,7 @@ 445 445 446 446 Measure the voltage value. The range is 0 to 30V. 447 447 448 -**Example**: 448 +**(% style="color:#037691" %)Example**: 449 449 450 450 138E(H) = 5006(D)/1000= 5.006V 451 451 ... ... @@ -455,7 +455,7 @@ 455 455 456 456 IN1 and IN2 are used as digital input pins. 457 457 458 -**Example**: 458 +**(% style="color:#037691" %)Example**: 459 459 460 460 09 (H) :(0x09&0x08)>>3=1 IN1 pin is high level. 461 461 ... ... @@ -464,7 +464,7 @@ 464 464 465 465 This data field shows if this packet is generated by **Interrupt Pin** or not. [[Click here>>path:#Int_mod]] for the hardware and software set up. Note: The Internet Pin is a separate pin in the screw terminal. 466 466 467 -**Example:** 467 +**(% style="color:#037691" %)Example:** 468 468 469 469 09 (H) : (0x09&0x02)>>1=1 The level of the interrupt pin. 470 470 ... ... @@ -497,9 +497,9 @@ 497 497 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 498 498 499 499 500 -**Step 1: **Be sure that your device is programmed and properly connected to the network at this time. 500 +**(% style="color:blue" %)Step 1: **(%%)Be sure that your device is programmed and properly connected to the network at this time. 501 501 502 -**Step 2:** To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps: 502 +**(% style="color:blue" %)Step 2:**(%%) To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps: 503 503 504 504 505 505 [[image:1675144951092-237.png]] ... ... @@ -508,9 +508,9 @@ 508 508 [[image:1675144960452-126.png]] 509 509 510 510 511 -**Step 3:** Create an account or log in Datacake. 511 +**(% style="color:blue" %)Step 3:**(%%) Create an account or log in Datacake. 512 512 513 -**Step 4:** Create PS-LB product. 513 +**(% style="color:#blue" %)Step 4:** (%%)Create PS-LB product. 514 514 515 515 [[image:1675145004465-869.png]] 516 516 ... ... @@ -523,7 +523,7 @@ 523 523 [[image:1675145029119-717.png]] 524 524 525 525 526 -**Step 5: **add payload decode 526 +**(% style="color:blue" %)Step 5: **(%%)add payload decode 527 527 528 528 [[image:1675145051360-659.png]] 529 529