<
From version < 42.32 >
edited by Xiaoling
on 2023/01/31 17:18
To version < 45.1 >
edited by Bei Jinggeng
on 2023/02/20 17:13
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -60,7 +60,6 @@
60 60  * 8500mAh Battery for long term use
61 61  
62 62  
63 -
64 64  == 1.3 Specification ==
65 65  
66 66  
... ... @@ -108,7 +108,6 @@
108 108  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
109 109  
110 110  
111 -
112 112  == 1.4 Probe Types ==
113 113  
114 114  === 1.4.1 Thread Installation Type ===
... ... @@ -128,7 +128,6 @@
128 128  * Connector Type: Various Types, see order info
129 129  
130 130  
131 -
132 132  === 1.4.2 Immersion Type ===
133 133  
134 134  
... ... @@ -146,7 +146,6 @@
146 146  * Material: 316 stainless steels
147 147  
148 148  
149 -
150 150  == 1.5 Probe Dimension ==
151 151  
152 152  
... ... @@ -218,7 +218,6 @@
218 218  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.
219 219  
220 220  
221 -
222 222  == 1.9 Pin Mapping ==
223 223  
224 224  
... ... @@ -243,8 +243,6 @@
243 243  == 1.11 Mechanical ==
244 244  
245 245  
246 -
247 -
248 248  [[image:1675143884058-338.png]]
249 249  
250 250  
... ... @@ -413,7 +413,21 @@
413 413  [[image:1675144608950-310.png]]
414 414  
415 415  
409 +(% class="wikigeneratedid" %)
410 +=== 2.3.3 Sensor value, FPORT~=7 ===
416 416  
412 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:543px" %)
413 +|(% style="width:99px" %)(((
414 +**Size(bytes)**
415 +)))|(% style="width:63px" %)2|(% style="width:378px" %)n
416 +|(% style="width:99px" %)Value|(% style="width:63px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:378px" %)(((
417 +Voltage value, each 2 bytes is a set of voltage values
418 +)))
419 +
420 +
421 +[[image:image-20230220171300-1.png||height="207" width="863"]]
422 +
423 +
417 417  === 2.3.3 Battery Info ===
418 418  
419 419  
... ... @@ -424,6 +424,7 @@
424 424  Ex2: 0x0B49 = 2889mV
425 425  
426 426  
434 +
427 427  === 2.3.4 Probe Model ===
428 428  
429 429  
... ... @@ -610,18 +610,16 @@
610 610  Set transmit interval to 60000ms = 60 seconds
611 611  )))
612 612  
613 -
614 614  (% style="color:blue" %)**Downlink Command: 0x01**
615 615  
616 616  Format: Command Code (0x01) followed by 3 bytes time value.
617 617  
618 -If the downlink payload=0100003C, it means set the END Nodes Transmit Interval to 0x00003C=60(S), while type code is 01.
625 +If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
619 619  
620 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
621 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
627 +* Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
628 +* Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
622 622  
623 623  
624 -
625 625  == 3.2 Set Interrupt Mode ==
626 626  
627 627  
... ... @@ -630,21 +630,20 @@
630 630  (% style="color:blue" %)**AT Command: AT+INTMOD**
631 631  
632 632  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
633 -|=**Command Example**|=**Function**|=**Response**
634 -|AT+INTMOD=?|Show current interrupt mode|(((
639 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 196px;" %)**Function**|=(% style="width: 157px;" %)**Response**
640 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
635 635  0
636 636  OK
637 637  the mode is 0 = No interruption
638 638  )))
639 -|AT+INTMOD=2|(((
645 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
640 640  Set Transmit Interval
641 641  ~1. (Disable Interrupt),
642 642  2. (Trigger by rising and falling edge)
643 643  3. (Trigger by falling edge)
644 644  4. (Trigger by rising edge)
645 -)))|OK
651 +)))|(% style="width:157px" %)OK
646 646  
647 -
648 648  (% style="color:blue" %)**Downlink Command: 0x06**
649 649  
650 650  Format: Command Code (0x06) followed by 3 bytes.
... ... @@ -651,11 +651,10 @@
651 651  
652 652  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
653 653  
654 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
655 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
659 +* Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
660 +* Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
656 656  
657 657  
658 -
659 659  == 3.3 Set the output time ==
660 660  
661 661  
... ... @@ -680,7 +680,6 @@
680 680  OK
681 681  )))
682 682  
683 -
684 684  (% style="color:blue" %)**AT Command: AT+5VT**
685 685  
686 686  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:470px" %)
... ... @@ -700,7 +700,6 @@
700 700  OK
701 701  )))
702 702  
703 -
704 704  (% style="color:blue" %)**AT Command: AT+12VT**
705 705  
706 706  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:443px" %)
... ... @@ -714,7 +714,6 @@
714 714  OK
715 715  )))
716 716  
717 -
718 718  (% style="color:blue" %)**Downlink Command: 0x07**
719 719  
720 720  Format: Command Code (0x07) followed by 3 bytes.
... ... @@ -729,7 +729,6 @@
729 729  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
730 730  
731 731  
732 -
733 733  == 3.4 Set the Probe Model ==
734 734  
735 735  
... ... @@ -749,7 +749,6 @@
749 749  OK
750 750  )))
751 751  
752 -
753 753  (% style="color:blue" %)**Downlink Command: 0x08**
754 754  
755 755  Format: Command Code (0x08) followed by 2 bytes.
... ... @@ -758,7 +758,40 @@
758 758  * Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
759 759  
760 760  
760 +== 3.5 Multiple collections are one uplink(Since firmware V1.1) ==
761 761  
762 +Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time.
763 +
764 +(% style="color:blue" %)**AT Command: AT** **+STDC**
765 +
766 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
767 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response**
768 +|(% style="width:156px" %)AT+STDC=?|(% style="width:137px" %)(((
769 +Get the mode of multiple acquisitions and one uplink
770 +)))|(((
771 +1,10,18
772 +OK
773 +)))
774 +|(% style="width:156px" %)AT+STDC=1,10,18|(% style="width:137px" %)Set the mode of multiple acquisitions and one uplink|(((
775 +OK
776 +
777 +aa:
778 +
779 +0 means disable this function and use TDC to send packets.
780 +
781 +1 means enable this function, use the method of multiple acquisitions to send packets.
782 +
783 +bb: Each collection interval (s), the value is 1~~65535
784 +
785 +cc: the number of collection times, the value is 1~~120
786 +)))
787 +
788 +(% style="color:blue" %)**Downlink Command: 0xAE**
789 +
790 +Format: Command Code (0x08) followed by 5 bytes.
791 +
792 +* Example 1: Downlink Payload: AE 01 02 58 12 **~-~-->**  AT+STDC=1,600,18
793 +
762 762  = 4. Battery & how to replace =
763 763  
764 764  == 4.1 Battery Type ==
... ... @@ -766,7 +766,6 @@
766 766  
767 767  PS-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
768 768  
769 -
770 770  The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
771 771  
772 772  [[image:1675146710956-626.png]]
... ... @@ -888,7 +888,6 @@
888 888  * Weight / pcs : g
889 889  
890 890  
891 -
892 892  = 10. Support =
893 893  
894 894  
... ... @@ -897,6 +897,4 @@
897 897  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
898 898  
899 899  
900 -
901 -
902 902  
image-20230201090514-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +560.9 KB
Content
image-20230220171300-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +98.0 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0