Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/03 14:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,17 +16,29 @@ 16 16 == 1.1 What is LoRaWAN Pressure Sensor == 17 17 18 18 19 +((( 19 19 The Dragino PS-LB series sensors are (% style="color:blue" %)**LoRaWAN Pressure Sensor**(%%) for Internet of Things solution. PS-LB can measure Air, Water pressure and liquid level and upload the sensor data via wireless to LoRaWAN IoT server. 21 +))) 20 20 23 +((( 21 21 The PS-LB series sensors include (% style="color:blue" %)**Thread Installation Type**(%%) and (% style="color:blue" %)**Immersion Type**(%%), it supports different pressure range which can be used for different measurement requirement. 25 +))) 22 22 27 +((( 23 23 The LoRa wireless technology used in PS-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 29 +))) 24 24 31 +((( 25 25 PS-LB supports BLE configure and wireless OTA update which make user easy to use. 33 +))) 26 26 35 +((( 27 27 PS-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 37 +))) 28 28 39 +((( 29 29 Each PS-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 41 +))) 30 30 31 31 [[image:1675071321348-194.png]] 32 32 ... ... @@ -639,39 +639,39 @@ 639 639 640 640 (% style="color:blue" %)**AT Command: AT+3V3T** 641 641 642 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width: 510px" %)643 -|=(% style="width: 15 6px;" %)**Command Example**|=(% style="width: 236px;" %)**Function**|=(% style="width: 117px;" %)**Response**644 -|(% style="width:15 6px" %)AT+3V3T=?|(% style="width:236px" %)Show 3V3 open time.|(% style="width:117px" %)(((654 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:474px" %) 655 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 201px;" %)**Function**|=(% style="width: 116px;" %)**Response** 656 +|(% style="width:154px" %)AT+3V3T=?|(% style="width:201px" %)Show 3V3 open time.|(% style="width:116px" %)((( 645 645 0 646 646 OK 647 647 ))) 648 -|(% style="width:15 6px" %)AT+3V3T=0|(% style="width:236px" %)Normally open 3V3 power supply.|(% style="width:117px" %)(((660 +|(% style="width:154px" %)AT+3V3T=0|(% style="width:201px" %)Normally open 3V3 power supply.|(% style="width:116px" %)((( 649 649 OK 650 650 default setting 651 651 ))) 652 -|(% style="width:15 6px" %)AT+3V3T=1000|(% style="width:236px" %)Close after a delay of 1000 milliseconds.|(% style="width:117px" %)(((664 +|(% style="width:154px" %)AT+3V3T=1000|(% style="width:201px" %)Close after a delay of 1000 milliseconds.|(% style="width:116px" %)((( 653 653 OK 654 654 ))) 655 -|(% style="width:15 6px" %)AT+3V3T=65535|(% style="width:236px" %)Normally closed 3V3 power supply.|(% style="width:117px" %)(((667 +|(% style="width:154px" %)AT+3V3T=65535|(% style="width:201px" %)Normally closed 3V3 power supply.|(% style="width:116px" %)((( 656 656 OK 657 657 ))) 658 658 659 659 (% style="color:blue" %)**AT Command: AT+5VT** 660 660 661 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width: 510px" %)662 -|=(% style="width: 15 8px;" %)**Command Example**|=(% style="width:232px;" %)**Function**|=(% style="width: 119px;" %)**Response**663 -|(% style="width:15 8px" %)AT+5VT=?|(% style="width:232px" %)Show 5V open time.|(% style="width:119px" %)(((673 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:470px" %) 674 +|=(% style="width: 155px;" %)**Command Example**|=(% style="width: 196px;" %)**Function**|=(% style="width: 114px;" %)**Response** 675 +|(% style="width:155px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:114px" %)((( 664 664 0 665 665 OK 666 666 ))) 667 -|(% style="width:15 8px" %)AT+5VT=0|(% style="width:232px" %)Normally closed 5V power supply.|(% style="width:119px" %)(((679 +|(% style="width:155px" %)AT+5VT=0|(% style="width:196px" %)Normally closed 5V power supply.|(% style="width:114px" %)((( 668 668 OK 669 669 default setting 670 670 ))) 671 -|(% style="width:15 8px" %)AT+5VT=1000|(% style="width:232px" %)Close after a delay of 1000 milliseconds.|(% style="width:119px" %)(((683 +|(% style="width:155px" %)AT+5VT=1000|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:114px" %)((( 672 672 OK 673 673 ))) 674 -|(% style="width:15 8px" %)AT+5VT=65535|(% style="width:232px" %)Normally open 5V power supply.|(% style="width:119px" %)(((686 +|(% style="width:155px" %)AT+5VT=65535|(% style="width:196px" %)Normally open 5V power supply.|(% style="width:114px" %)((( 675 675 OK 676 676 ))) 677 677 ... ... @@ -706,17 +706,17 @@ 706 706 707 707 (% style="color:blue" %)**AT Command: AT** **+PROBE** 708 708 709 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width: 510px" %)710 -|=(% style="width: 15 7px;" %)**Command Example**|=(% style="width: 267px;" %)**Function**|=**Response**711 -|(% style="width:15 7px" %)AT +PROBE =?|(% style="width:267px" %)Get or Set the probe model.|(((721 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:448px" %) 722 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 204px;" %)**Function**|=(% style="width: 85px;" %)**Response** 723 +|(% style="width:154px" %)AT +PROBE =?|(% style="width:204px" %)Get or Set the probe model.|(% style="width:85px" %)((( 712 712 0 713 713 OK 714 714 ))) 715 -|(% style="width:15 7px" %)AT +PROBE =0003|(% style="width:267px" %)Set water depth sensor mode, 3m type.|OK716 -|(% style="width:15 7px" %)AT +PROBE =0101|(% style="width:267px" %)Set pressure transmitters mode, first type.|(((727 +|(% style="width:154px" %)AT +PROBE =0003|(% style="width:204px" %)Set water depth sensor mode, 3m type.|(% style="width:85px" %)OK 728 +|(% style="width:154px" %)AT +PROBE =0101|(% style="width:204px" %)Set pressure transmitters mode, first type.|(% style="width:85px" %)((( 717 717 OK 718 718 ))) 719 -|(% style="width:15 7px" %)AT +PROBE =0000|(% style="width:267px" %)Initial state, no settings.|(((731 +|(% style="width:154px" %)AT +PROBE =0000|(% style="width:204px" %)Initial state, no settings.|(% style="width:85px" %)((( 720 720 OK 721 721 ))) 722 722