... ... @@ -612,11 +612,14 @@
612 612  |=**Command Example**|=**Function**|=**Response**
613 613  |AT+INTMOD=?|Show current interrupt mode|(((
614 614  0
615 +
615 615  OK
617 +
616 616  the mode is 0 = No interruption
617 617  )))
618 618  |AT+INTMOD=2|(((
619 619  Set Transmit Interval
622 +
620 620  ~1. (Disable Interrupt),
621 621  
622 622  2. (Trigger by rising and falling edge),
... ... @@ -646,17 +646,23 @@
646 646  |=(% style="width: 156px;" %)**Command Example**|=(% style="width: 236px;" %)**Function**|=(% style="width: 117px;" %)**Response**
647 647  |(% style="width:156px" %)AT+3V3T=?|(% style="width:236px" %)Show 3V3 open time.|(% style="width:117px" %)(((
648 648  0
652 +
649 649  OK
650 650  )))
651 651  |(% style="width:156px" %)AT+3V3T=0|(% style="width:236px" %)Normally open 3V3 power supply.|(% style="width:117px" %)(((
652 652  OK
657 +
653 653  default setting
654 654  )))
655 655  |(% style="width:156px" %)AT+3V3T=1000|(% style="width:236px" %)Close after a delay of 1000 milliseconds.|(% style="width:117px" %)(((
656 656  OK
662 +
663 +
657 657  )))
658 658  |(% style="width:156px" %)AT+3V3T=65535|(% style="width:236px" %)Normally closed 3V3 power supply.|(% style="width:117px" %)(((
659 659  OK
667 +
668 +
660 660  )))
661 661  
662 662  (% style="color:blue" %)**AT Command: AT+5VT**
... ... @@ -665,17 +665,23 @@
665 665  |=(% style="width: 158px;" %)**Command Example**|=(% style="width: 232px;" %)**Function**|=(% style="width: 119px;" %)**Response**
666 666  |(% style="width:158px" %)AT+5VT=?|(% style="width:232px" %)Show 5V open time.|(% style="width:119px" %)(((
667 667  0
677 +
668 668  OK
669 669  )))
670 670  |(% style="width:158px" %)AT+5VT=0|(% style="width:232px" %)Normally closed 5V power supply.|(% style="width:119px" %)(((
671 671  OK
682 +
672 672  default setting
673 673  )))
674 674  |(% style="width:158px" %)AT+5VT=1000|(% style="width:232px" %)Close after a delay of 1000 milliseconds.|(% style="width:119px" %)(((
675 675  OK
687 +
688 +
676 676  )))
677 677  |(% style="width:158px" %)AT+5VT=65535|(% style="width:232px" %)Normally open 5V power supply.|(% style="width:119px" %)(((
678 678  OK
692 +
693 +
679 679  )))
680 680  
681 681  (% style="color:blue" %)**AT Command: AT+12VT**
... ... @@ -684,11 +684,14 @@
684 684  |=(% style="width: 156px;" %)**Command Example**|=(% style="width: 268px;" %)**Function**|=**Response**
685 685  |(% style="width:156px" %)AT+12VT=?|(% style="width:268px" %)Show 12V open time.|(((
686 686  0
702 +
687 687  OK
688 688  )))
689 689  |(% style="width:156px" %)AT+12VT=0|(% style="width:268px" %)Normally closed 12V power supply.|OK
690 690  |(% style="width:156px" %)AT+12VT=500|(% style="width:268px" %)Close after a delay of 500 milliseconds.|(((
691 691  OK
708 +
709 +
692 692  )))
693 693  
694 694  (% style="color:blue" %)**Downlink Command: 0x07**
... ... @@ -713,14 +713,19 @@
713 713  |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 267px;" %)**Function**|=**Response**
714 714  |(% style="width:157px" %)AT +PROBE =?|(% style="width:267px" %)Get or Set the probe model.|(((
715 715  0
734 +
716 716  OK
717 717  )))
718 718  |(% style="width:157px" %)AT +PROBE =0003|(% style="width:267px" %)Set water depth sensor mode, 3m type.|OK
719 719  |(% style="width:157px" %)AT +PROBE =0101|(% style="width:267px" %)Set pressure transmitters mode, first type.|(((
720 720  OK
740 +
741 +
721 721  )))
722 722  |(% style="width:157px" %)AT +PROBE =0000|(% style="width:267px" %)Initial state, no settings.|(((
723 723  OK
745 +
746 +
724 724  )))
725 725  
726 726  (% style="color:blue" %)**Downlink Command: 0x08**