... ... @@ -187,18 +187,22 @@
187 187  
188 188  
189 189  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
190 -|=(% style="width: 150px;" %)**Behavior on ACT**|=(% style="width: 90px;" %)**Function**|=**Action**
191 -|(% style="width:260px" %)Pressing ACT between 1s < time < 3s|(% style="width:100px" %)Send an uplink|(((
190 +|(% style="width:138px" %)**Behavior on ACT**|(% style="width:100px" %)**Function**|**Action**
191 +|(% style="width:138px" %)Pressing ACT between 1s < time < 3s|(% style="width:100px" %)Send an uplink|(((
192 192  If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once.
193 +
193 193  Meanwhile, BLE module will be active and user can connect via BLE to configure device.
194 194  )))
195 195  |(% style="width:138px" %)Pressing ACT for more than 3s|(% style="width:100px" %)Active Device|(((
196 196  (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network.
198 +
197 197  (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
200 +
198 198  Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network.
199 199  )))
200 200  |(% style="width:138px" %)Fast press ACT 5 times.|(% style="width:100px" %)Deactivate Device|red led will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.
201 201  
205 +
202 202  == 1.9 Pin Mapping ==
203 203  
204 204  
... ... @@ -388,8 +388,8 @@
388 388  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
389 389  |(% style="width:97px" %)(((
390 390  **Size(bytes)**
391 -)))|(% style="width:48px" %)**2**|(% style="width:71px" %)**2**|(% style="width:98px" %)**2**|(% style="width:73px" %)**2**|(% style="width:122px" %)**1**
392 -|(% style="width:97px" %)**Value**|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt  flag>>||anchor="H2.3.7IN126IN226INTpin"]]
395 +)))|(% style="width:48px" %)**2**|(% style="width:58px" %)**2**|**2**|**2**|**1**
396 +|(% style="width:97px" %)**Value**|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:58px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|[[IN1 &IN2 Interrupt  flag>>||anchor="H2.3.7IN126IN226INTpin"]]
393 393  
394 394  [[image:1675144608950-310.png]]
395 395  
... ... @@ -501,7 +501,7 @@
501 501  
502 502  (% style="color:blue" %)**Step 3:**(%%) Create an account or log in Datacake.
503 503  
504 -(% style="color:blue" %)**Step 4:** (%%)Create PS-LB product.
508 +(% style="color:#blue" %)**Step 4:** (%%)Create PS-LB product.
505 505  
506 506  [[image:1675145004465-869.png]]
507 507  
... ... @@ -551,12 +551,12 @@
551 551  
552 552  Use can configure PS-LB via AT Command or LoRaWAN Downlink.
553 553  
554 -* AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]].
558 +* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
555 555  * LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
556 556  
557 557  There are two kinds of commands to configure PS-LB, they are:
558 558  
559 -* (% style="color:#037691" %)**General Commands**.
563 +* **General Commands**.
560 560  
561 561  These commands are to configure:
562 562  
... ... @@ -568,7 +568,7 @@
568 568  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
569 569  
570 570  
571 -* (% style="color:#037691" %)**Commands special design for PS-LB**
575 +* **Commands special design for PS-LB**
572 572  
573 573  These commands only valid for PS-LB, as below:
574 574  
... ... @@ -578,21 +578,24 @@
578 578  
579 579  Feature: Change LoRaWAN End Node Transmit Interval.
580 580  
581 -(% style="color:blue" %)**AT Command: AT+TDC**
585 +**AT Command: AT+TDC**
582 582  
583 583  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
584 -|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response**
585 -|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|(((
588 +|**Command Example**|**Function**|**Response**
589 +|AT+TDC=?|Show current transmit Interval|(((
586 586  30000
591 +
587 587  OK
593 +
588 588  the interval is 30000ms = 30s
589 589  )))
590 -|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|(((
596 +|AT+TDC=60000|Set Transmit Interval|(((
591 591  OK
598 +
592 592  Set transmit interval to 60000ms = 60 seconds
593 593  )))
594 594  
595 -(% style="color:blue" %)**Downlink Command: 0x01**
602 +**Downlink Command: 0x01**
596 596  
597 597  Format: Command Code (0x01) followed by 3 bytes time value.
598 598  
... ... @@ -606,17 +606,20 @@
606 606  
607 607  Feature, Set Interrupt mode for GPIO_EXIT.
608 608  
609 -(% style="color:blue" %)**AT Command: AT+INTMOD**
616 +**AT Command: AT+INTMOD**
610 610  
611 611  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
612 -|=**Command Example**|=**Function**|=**Response**
619 +|**Command Example**|**Function**|**Response**
613 613  |AT+INTMOD=?|Show current interrupt mode|(((
614 614  0
622 +
615 615  OK
624 +
616 616  the mode is 0 = No interruption
617 617  )))
618 618  |AT+INTMOD=2|(((
619 619  Set Transmit Interval
629 +
620 620  ~1. (Disable Interrupt),
621 621  
622 622  2. (Trigger by rising and falling edge),
... ... @@ -626,7 +626,7 @@
626 626  4. (Trigger by rising edge)
627 627  )))|OK
628 628  
629 -(% style="color:blue" %)**Downlink Command: 0x06**
639 +**Downlink Command: 0x06**
630 630  
631 631  Format: Command Code (0x06) followed by 3 bytes.
632 632  
... ... @@ -635,63 +635,79 @@
635 635  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
636 636  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
637 637  
648 +
638 638  == 3.3 Set the output time ==
639 639  
640 640  
641 641  Feature, Control the output 3V3 , 5V or 12V.
642 642  
643 -(% style="color:blue" %)**AT Command: AT+3V3T**
654 +**AT Command: AT+3V3T**
644 644  
645 645  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
646 -|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 236px;" %)**Function**|=(% style="width: 117px;" %)**Response**
657 +|(% style="width:156px" %)**Command Example**|(% style="width:236px" %)**Function**|(% style="width:117px" %)**Response**
647 647  |(% style="width:156px" %)AT+3V3T=?|(% style="width:236px" %)Show 3V3 open time.|(% style="width:117px" %)(((
648 648  0
660 +
649 649  OK
650 650  )))
651 651  |(% style="width:156px" %)AT+3V3T=0|(% style="width:236px" %)Normally open 3V3 power supply.|(% style="width:117px" %)(((
652 652  OK
665 +
653 653  default setting
654 654  )))
655 655  |(% style="width:156px" %)AT+3V3T=1000|(% style="width:236px" %)Close after a delay of 1000 milliseconds.|(% style="width:117px" %)(((
656 656  OK
670 +
671 +
657 657  )))
658 658  |(% style="width:156px" %)AT+3V3T=65535|(% style="width:236px" %)Normally closed 3V3 power supply.|(% style="width:117px" %)(((
659 659  OK
675 +
676 +
660 660  )))
661 661  
662 -(% style="color:blue" %)**AT Command: AT+5VT**
679 +**AT Command: AT+5VT**
663 663  
664 664  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
665 -|=(% style="width: 158px;" %)**Command Example**|=(% style="width: 232px;" %)**Function**|=(% style="width: 119px;" %)**Response**
682 +|(% style="width:158px" %)**Command Example**|(% style="width:232px" %)**Function**|(% style="width:119px" %)**Response**
666 666  |(% style="width:158px" %)AT+5VT=?|(% style="width:232px" %)Show 5V open time.|(% style="width:119px" %)(((
667 667  0
685 +
668 668  OK
669 669  )))
670 670  |(% style="width:158px" %)AT+5VT=0|(% style="width:232px" %)Normally closed 5V power supply.|(% style="width:119px" %)(((
671 671  OK
690 +
672 672  default setting
673 673  )))
674 674  |(% style="width:158px" %)AT+5VT=1000|(% style="width:232px" %)Close after a delay of 1000 milliseconds.|(% style="width:119px" %)(((
675 675  OK
695 +
696 +
676 676  )))
677 677  |(% style="width:158px" %)AT+5VT=65535|(% style="width:232px" %)Normally open 5V power supply.|(% style="width:119px" %)(((
678 678  OK
700 +
701 +
679 679  )))
680 680  
681 -(% style="color:blue" %)**AT Command: AT+12VT**
704 +**AT Command: AT+12VT**
682 682  
683 683  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
684 -|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 268px;" %)**Function**|=**Response**
707 +|(% style="width:156px" %)**Command Example**|(% style="width:268px" %)**Function**|**Response**
685 685  |(% style="width:156px" %)AT+12VT=?|(% style="width:268px" %)Show 12V open time.|(((
686 686  0
710 +
687 687  OK
688 688  )))
689 689  |(% style="width:156px" %)AT+12VT=0|(% style="width:268px" %)Normally closed 12V power supply.|OK
690 690  |(% style="width:156px" %)AT+12VT=500|(% style="width:268px" %)Close after a delay of 500 milliseconds.|(((
691 691  OK
716 +
717 +
692 692  )))
693 693  
694 -(% style="color:blue" %)**Downlink Command: 0x07**
720 +**Downlink Command: 0x07**
695 695  
696 696  Format: Command Code (0x07) followed by 3 bytes.
697 697  
... ... @@ -704,26 +704,32 @@
704 704  * Example 5: Downlink Payload: 070301F4  -> AT+12VT=500
705 705  * Example 6: Downlink Payload: 07030000  -> AT+12VT=0
706 706  
733 +
707 707  == 3.4 Set the Probe Model ==
708 708  
709 709  
710 -(% style="color:blue" %)**AT Command: AT** **+PROBE**
737 +**AT Command: AT** **+PROBE**
711 711  
712 712  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
713 -|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 267px;" %)**Function**|=**Response**
740 +|(% style="width:157px" %)**Command Example**|(% style="width:267px" %)**Function**|**Response**
714 714  |(% style="width:157px" %)AT +PROBE =?|(% style="width:267px" %)Get or Set the probe model.|(((
715 715  0
743 +
716 716  OK
717 717  )))
718 718  |(% style="width:157px" %)AT +PROBE =0003|(% style="width:267px" %)Set water depth sensor mode, 3m type.|OK
719 719  |(% style="width:157px" %)AT +PROBE =0101|(% style="width:267px" %)Set pressure transmitters mode, first type.|(((
720 720  OK
749 +
750 +
721 721  )))
722 722  |(% style="width:157px" %)AT +PROBE =0000|(% style="width:267px" %)Initial state, no settings.|(((
723 723  OK
754 +
755 +
724 724  )))
725 725  
726 -(% style="color:blue" %)**Downlink Command: 0x08**
758 +**Downlink Command: 0x08**
727 727  
728 728  Format: Command Code (0x08) followed by 2 bytes.
729 729  
... ... @@ -730,6 +730,7 @@
730 730  * Example 1: Downlink Payload: 080003  -> AT+PROBE=0003
731 731  * Example 2: Downlink Payload: 080101  -> AT+PROBE=0101
732 732  
765 +
733 733  = 4. Battery & how to replace =
734 734  
735 735  == 4.1 Battery Type ==
... ... @@ -765,12 +765,12 @@
765 765  Instruction to use as below:
766 766  
767 767  
768 -(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
801 +**Step 1:** Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
769 769  
770 770  [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]]
771 771  
772 772  
773 -(% style="color:blue" %)**Step 2:**(%%) Open it and choose
806 +**Step 2:** Open it and choose
774 774  
775 775  * Product Model
776 776  * Uplink Interval
... ... @@ -852,11 +852,11 @@
852 852  = 9. ​Packing Info =
853 853  
854 854  
855 -(% style="color:#037691" %)**Package Includes**:
888 +**Package Includes**:
856 856  
857 857  * PS-LB LoRaWAN Pressure Sensor
858 858  
859 -(% style="color:#037691" %)**Dimension and weight**:
892 +**Dimension and weight**:
860 860  
861 861  * Device Size: cm
862 862  * Device Weight: g
... ... @@ -863,11 +863,11 @@
863 863  * Package Size / pcs : cm
864 864  * Weight / pcs : g
865 865  
899 +
866 866  = 10. Support =
867 867  
868 868  
869 869  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
870 -
871 871  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
872 872  
873 873  