Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,17 +16,29 @@ 16 16 == 1.1 What is LoRaWAN Pressure Sensor == 17 17 18 18 19 +((( 19 19 The Dragino PS-LB series sensors are (% style="color:blue" %)**LoRaWAN Pressure Sensor**(%%) for Internet of Things solution. PS-LB can measure Air, Water pressure and liquid level and upload the sensor data via wireless to LoRaWAN IoT server. 21 +))) 20 20 23 +((( 21 21 The PS-LB series sensors include (% style="color:blue" %)**Thread Installation Type**(%%) and (% style="color:blue" %)**Immersion Type**(%%), it supports different pressure range which can be used for different measurement requirement. 25 +))) 22 22 27 +((( 23 23 The LoRa wireless technology used in PS-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 29 +))) 24 24 31 +((( 25 25 PS-LB supports BLE configure and wireless OTA update which make user easy to use. 33 +))) 26 26 35 +((( 27 27 PS-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years. 37 +))) 28 28 39 +((( 29 29 Each PS-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 41 +))) 30 30 31 31 [[image:1675071321348-194.png]] 32 32 ... ... @@ -612,20 +612,14 @@ 612 612 |=**Command Example**|=**Function**|=**Response** 613 613 |AT+INTMOD=?|Show current interrupt mode|((( 614 614 0 615 - 616 616 OK 617 - 618 618 the mode is 0 = No interruption 619 619 ))) 620 620 |AT+INTMOD=2|((( 621 621 Set Transmit Interval 622 - 623 623 ~1. (Disable Interrupt), 624 - 625 -2. (Trigger by rising and falling edge), 626 - 633 +2. (Trigger by rising and falling edge) 627 627 3. (Trigger by falling edge) 628 - 629 629 4. (Trigger by rising edge) 630 630 )))|OK 631 631 ... ... @@ -645,68 +645,53 @@ 645 645 646 646 (% style="color:blue" %)**AT Command: AT+3V3T** 647 647 648 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width: 510px" %)649 -|=(% style="width: 15 6px;" %)**Command Example**|=(% style="width: 236px;" %)**Function**|=(% style="width: 117px;" %)**Response**650 -|(% style="width:15 6px" %)AT+3V3T=?|(% style="width:236px" %)Show 3V3 open time.|(% style="width:117px" %)(((654 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:474px" %) 655 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 201px;" %)**Function**|=(% style="width: 116px;" %)**Response** 656 +|(% style="width:154px" %)AT+3V3T=?|(% style="width:201px" %)Show 3V3 open time.|(% style="width:116px" %)((( 651 651 0 652 - 653 653 OK 654 654 ))) 655 -|(% style="width:15 6px" %)AT+3V3T=0|(% style="width:236px" %)Normally open 3V3 power supply.|(% style="width:117px" %)(((660 +|(% style="width:154px" %)AT+3V3T=0|(% style="width:201px" %)Normally open 3V3 power supply.|(% style="width:116px" %)((( 656 656 OK 657 - 658 658 default setting 659 659 ))) 660 -|(% style="width:15 6px" %)AT+3V3T=1000|(% style="width:236px" %)Close after a delay of 1000 milliseconds.|(% style="width:117px" %)(((664 +|(% style="width:154px" %)AT+3V3T=1000|(% style="width:201px" %)Close after a delay of 1000 milliseconds.|(% style="width:116px" %)((( 661 661 OK 662 - 663 - 664 664 ))) 665 -|(% style="width:15 6px" %)AT+3V3T=65535|(% style="width:236px" %)Normally closed 3V3 power supply.|(% style="width:117px" %)(((667 +|(% style="width:154px" %)AT+3V3T=65535|(% style="width:201px" %)Normally closed 3V3 power supply.|(% style="width:116px" %)((( 666 666 OK 667 - 668 - 669 669 ))) 670 670 671 671 (% style="color:blue" %)**AT Command: AT+5VT** 672 672 673 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width: 510px" %)674 -|=(% style="width: 15 8px;" %)**Command Example**|=(% style="width:232px;" %)**Function**|=(% style="width: 119px;" %)**Response**675 -|(% style="width:15 8px" %)AT+5VT=?|(% style="width:232px" %)Show 5V open time.|(% style="width:119px" %)(((673 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:470px" %) 674 +|=(% style="width: 155px;" %)**Command Example**|=(% style="width: 196px;" %)**Function**|=(% style="width: 114px;" %)**Response** 675 +|(% style="width:155px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:114px" %)((( 676 676 0 677 - 678 678 OK 679 679 ))) 680 -|(% style="width:15 8px" %)AT+5VT=0|(% style="width:232px" %)Normally closed 5V power supply.|(% style="width:119px" %)(((679 +|(% style="width:155px" %)AT+5VT=0|(% style="width:196px" %)Normally closed 5V power supply.|(% style="width:114px" %)((( 681 681 OK 682 - 683 683 default setting 684 684 ))) 685 -|(% style="width:15 8px" %)AT+5VT=1000|(% style="width:232px" %)Close after a delay of 1000 milliseconds.|(% style="width:119px" %)(((683 +|(% style="width:155px" %)AT+5VT=1000|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:114px" %)((( 686 686 OK 687 - 688 - 689 689 ))) 690 -|(% style="width:15 8px" %)AT+5VT=65535|(% style="width:232px" %)Normally open 5V power supply.|(% style="width:119px" %)(((686 +|(% style="width:155px" %)AT+5VT=65535|(% style="width:196px" %)Normally open 5V power supply.|(% style="width:114px" %)((( 691 691 OK 692 - 693 - 694 694 ))) 695 695 696 696 (% style="color:blue" %)**AT Command: AT+12VT** 697 697 698 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width: 510px" %)699 -|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 268px;" %)**Function**|=**Response**700 -|(% style="width:156px" %)AT+12VT=?|(% style="width: 268px" %)Show 12V open time.|(((692 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:443px" %) 693 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 199px;" %)**Function**|=(% style="width: 83px;" %)**Response** 694 +|(% style="width:156px" %)AT+12VT=?|(% style="width:199px" %)Show 12V open time.|(% style="width:83px" %)((( 701 701 0 702 - 703 703 OK 704 704 ))) 705 -|(% style="width:156px" %)AT+12VT=0|(% style="width: 268px" %)Normally closed 12V power supply.|OK706 -|(% style="width:156px" %)AT+12VT=500|(% style="width: 268px" %)Close after a delay of 500 milliseconds.|(((698 +|(% style="width:156px" %)AT+12VT=0|(% style="width:199px" %)Normally closed 12V power supply.|(% style="width:83px" %)OK 699 +|(% style="width:156px" %)AT+12VT=500|(% style="width:199px" %)Close after a delay of 500 milliseconds.|(% style="width:83px" %)((( 707 707 OK 708 - 709 - 710 710 ))) 711 711 712 712 (% style="color:blue" %)**Downlink Command: 0x07** ... ... @@ -727,23 +727,18 @@ 727 727 728 728 (% style="color:blue" %)**AT Command: AT** **+PROBE** 729 729 730 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width: 510px" %)731 -|=(% style="width: 15 7px;" %)**Command Example**|=(% style="width: 267px;" %)**Function**|=**Response**732 -|(% style="width:15 7px" %)AT +PROBE =?|(% style="width:267px" %)Get or Set the probe model.|(((721 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:448px" %) 722 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 204px;" %)**Function**|=(% style="width: 85px;" %)**Response** 723 +|(% style="width:154px" %)AT +PROBE =?|(% style="width:204px" %)Get or Set the probe model.|(% style="width:85px" %)((( 733 733 0 734 - 735 735 OK 736 736 ))) 737 -|(% style="width:15 7px" %)AT +PROBE =0003|(% style="width:267px" %)Set water depth sensor mode, 3m type.|OK738 -|(% style="width:15 7px" %)AT +PROBE =0101|(% style="width:267px" %)Set pressure transmitters mode, first type.|(((727 +|(% style="width:154px" %)AT +PROBE =0003|(% style="width:204px" %)Set water depth sensor mode, 3m type.|(% style="width:85px" %)OK 728 +|(% style="width:154px" %)AT +PROBE =0101|(% style="width:204px" %)Set pressure transmitters mode, first type.|(% style="width:85px" %)((( 739 739 OK 740 - 741 - 742 742 ))) 743 -|(% style="width:15 7px" %)AT +PROBE =0000|(% style="width:267px" %)Initial state, no settings.|(((731 +|(% style="width:154px" %)AT +PROBE =0000|(% style="width:204px" %)Initial state, no settings.|(% style="width:85px" %)((( 744 744 OK 745 - 746 - 747 747 ))) 748 748 749 749 (% style="color:blue" %)**Downlink Command: 0x08**