Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/03 14:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -612,20 +612,14 @@ 612 612 |=**Command Example**|=**Function**|=**Response** 613 613 |AT+INTMOD=?|Show current interrupt mode|((( 614 614 0 615 - 616 616 OK 617 - 618 618 the mode is 0 = No interruption 619 619 ))) 620 620 |AT+INTMOD=2|((( 621 621 Set Transmit Interval 622 - 623 623 ~1. (Disable Interrupt), 624 - 625 -2. (Trigger by rising and falling edge), 626 - 621 +2. (Trigger by rising and falling edge) 627 627 3. (Trigger by falling edge) 628 - 629 629 4. (Trigger by rising edge) 630 630 )))|OK 631 631 ... ... @@ -649,23 +649,17 @@ 649 649 |=(% style="width: 156px;" %)**Command Example**|=(% style="width: 236px;" %)**Function**|=(% style="width: 117px;" %)**Response** 650 650 |(% style="width:156px" %)AT+3V3T=?|(% style="width:236px" %)Show 3V3 open time.|(% style="width:117px" %)((( 651 651 0 652 - 653 653 OK 654 654 ))) 655 655 |(% style="width:156px" %)AT+3V3T=0|(% style="width:236px" %)Normally open 3V3 power supply.|(% style="width:117px" %)((( 656 656 OK 657 - 658 658 default setting 659 659 ))) 660 660 |(% style="width:156px" %)AT+3V3T=1000|(% style="width:236px" %)Close after a delay of 1000 milliseconds.|(% style="width:117px" %)((( 661 661 OK 662 - 663 - 664 664 ))) 665 665 |(% style="width:156px" %)AT+3V3T=65535|(% style="width:236px" %)Normally closed 3V3 power supply.|(% style="width:117px" %)((( 666 666 OK 667 - 668 - 669 669 ))) 670 670 671 671 (% style="color:blue" %)**AT Command: AT+5VT** ... ... @@ -674,39 +674,30 @@ 674 674 |=(% style="width: 158px;" %)**Command Example**|=(% style="width: 232px;" %)**Function**|=(% style="width: 119px;" %)**Response** 675 675 |(% style="width:158px" %)AT+5VT=?|(% style="width:232px" %)Show 5V open time.|(% style="width:119px" %)((( 676 676 0 677 - 678 678 OK 679 679 ))) 680 680 |(% style="width:158px" %)AT+5VT=0|(% style="width:232px" %)Normally closed 5V power supply.|(% style="width:119px" %)((( 681 681 OK 682 - 683 683 default setting 684 684 ))) 685 685 |(% style="width:158px" %)AT+5VT=1000|(% style="width:232px" %)Close after a delay of 1000 milliseconds.|(% style="width:119px" %)((( 686 686 OK 687 - 688 - 689 689 ))) 690 690 |(% style="width:158px" %)AT+5VT=65535|(% style="width:232px" %)Normally open 5V power supply.|(% style="width:119px" %)((( 691 691 OK 692 - 693 - 694 694 ))) 695 695 696 696 (% style="color:blue" %)**AT Command: AT+12VT** 697 697 698 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width: 510px" %)699 -|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 268px;" %)**Function**|=**Response**700 -|(% style="width:156px" %)AT+12VT=?|(% style="width: 268px" %)Show 12V open time.|(((680 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:443px" %) 681 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 199px;" %)**Function**|=(% style="width: 83px;" %)**Response** 682 +|(% style="width:156px" %)AT+12VT=?|(% style="width:199px" %)Show 12V open time.|(% style="width:83px" %)((( 701 701 0 702 - 703 703 OK 704 704 ))) 705 -|(% style="width:156px" %)AT+12VT=0|(% style="width: 268px" %)Normally closed 12V power supply.|OK706 -|(% style="width:156px" %)AT+12VT=500|(% style="width: 268px" %)Close after a delay of 500 milliseconds.|(((686 +|(% style="width:156px" %)AT+12VT=0|(% style="width:199px" %)Normally closed 12V power supply.|(% style="width:83px" %)OK 687 +|(% style="width:156px" %)AT+12VT=500|(% style="width:199px" %)Close after a delay of 500 milliseconds.|(% style="width:83px" %)((( 707 707 OK 708 - 709 - 710 710 ))) 711 711 712 712 (% style="color:blue" %)**Downlink Command: 0x07** ... ... @@ -731,19 +731,14 @@ 731 731 |=(% style="width: 157px;" %)**Command Example**|=(% style="width: 267px;" %)**Function**|=**Response** 732 732 |(% style="width:157px" %)AT +PROBE =?|(% style="width:267px" %)Get or Set the probe model.|((( 733 733 0 734 - 735 735 OK 736 736 ))) 737 737 |(% style="width:157px" %)AT +PROBE =0003|(% style="width:267px" %)Set water depth sensor mode, 3m type.|OK 738 738 |(% style="width:157px" %)AT +PROBE =0101|(% style="width:267px" %)Set pressure transmitters mode, first type.|((( 739 739 OK 740 - 741 - 742 742 ))) 743 743 |(% style="width:157px" %)AT +PROBE =0000|(% style="width:267px" %)Initial state, no settings.|((( 744 744 OK 745 - 746 - 747 747 ))) 748 748 749 749 (% style="color:blue" %)**Downlink Command: 0x08**