Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -187,18 +187,22 @@ 187 187 188 188 189 189 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 190 -| =(% style="width:50px;" %)**Behavior on ACT**|=(% style="width:90px;" %)**Function**|=**Action**191 -|(% style="width: 260px" %)Pressing ACT between 1s < time < 3s|(% style="width:100px" %)Send an uplink|(((190 +|(% style="width:138px" %)**Behavior on ACT**|(% style="width:100px" %)**Function**|**Action** 191 +|(% style="width:138px" %)Pressing ACT between 1s < time < 3s|(% style="width:100px" %)Send an uplink|((( 192 192 If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once. 193 + 193 193 Meanwhile, BLE module will be active and user can connect via BLE to configure device. 194 194 ))) 195 195 |(% style="width:138px" %)Pressing ACT for more than 3s|(% style="width:100px" %)Active Device|((( 196 196 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. 198 + 197 197 (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 200 + 198 198 Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network. 199 199 ))) 200 200 |(% style="width:138px" %)Fast press ACT 5 times.|(% style="width:100px" %)Deactivate Device|red led will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 201 201 205 + 202 202 == 1.9 Pin Mapping == 203 203 204 204 ... ... @@ -388,8 +388,8 @@ 388 388 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 389 389 |(% style="width:97px" %)((( 390 390 **Size(bytes)** 391 -)))|(% style="width:48px" %)**2**|(% style="width: 71px" %)**2**|(% style="width:98px" %)**2**|(% style="width:73px" %)**2**|(% style="width:122px" %)**1**392 -|(% style="width:97px" %)**Value**|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width: 71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.7IN126IN226INTpin"]]395 +)))|(% style="width:48px" %)**2**|(% style="width:58px" %)**2**|**2**|**2**|**1** 396 +|(% style="width:97px" %)**Value**|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:58px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.7IN126IN226INTpin"]] 393 393 394 394 [[image:1675144608950-310.png]] 395 395 ... ... @@ -501,7 +501,7 @@ 501 501 502 502 (% style="color:blue" %)**Step 3:**(%%) Create an account or log in Datacake. 503 503 504 -(% style="color:blue" %)**Step 4:** (%%)Create PS-LB product. 508 +(% style="color:#blue" %)**Step 4:** (%%)Create PS-LB product. 505 505 506 506 [[image:1675145004465-869.png]] 507 507 ... ... @@ -551,12 +551,12 @@ 551 551 552 552 Use can configure PS-LB via AT Command or LoRaWAN Downlink. 553 553 554 -* AT Command Connection: See [[FAQ>> ||anchor="H7.FAQ"]].558 +* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]]. 555 555 * LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 556 556 557 557 There are two kinds of commands to configure PS-LB, they are: 558 558 559 -* (% style="color:#037691" %)**General Commands**.563 +* **General Commands**. 560 560 561 561 These commands are to configure: 562 562 ... ... @@ -568,7 +568,7 @@ 568 568 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 569 569 570 570 571 -* (% style="color:#037691" %)**Commands special design for PS-LB**575 +* **Commands special design for PS-LB** 572 572 573 573 These commands only valid for PS-LB, as below: 574 574 ... ... @@ -578,21 +578,24 @@ 578 578 579 579 Feature: Change LoRaWAN End Node Transmit Interval. 580 580 581 - (% style="color:blue" %)**AT Command: AT+TDC**585 +**AT Command: AT+TDC** 582 582 583 583 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 584 -| =(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response**585 -| (% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|(((588 +|**Command Example**|**Function**|**Response** 589 +|AT+TDC=?|Show current transmit Interval|((( 586 586 30000 591 + 587 587 OK 593 + 588 588 the interval is 30000ms = 30s 589 589 ))) 590 -| (% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|(((596 +|AT+TDC=60000|Set Transmit Interval|((( 591 591 OK 598 + 592 592 Set transmit interval to 60000ms = 60 seconds 593 593 ))) 594 594 595 - (% style="color:blue" %)**Downlink Command: 0x01**602 +**Downlink Command: 0x01** 596 596 597 597 Format: Command Code (0x01) followed by 3 bytes time value. 598 598 ... ... @@ -606,10 +606,10 @@ 606 606 607 607 Feature, Set Interrupt mode for GPIO_EXIT. 608 608 609 - (% style="color:blue" %)**AT Command: AT+INTMOD**616 +**AT Command: AT+INTMOD** 610 610 611 611 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 612 -| =**Command Example**|=**Function**|=**Response**619 +|**Command Example**|**Function**|**Response** 613 613 |AT+INTMOD=?|Show current interrupt mode|((( 614 614 0 615 615 ... ... @@ -629,7 +629,7 @@ 629 629 4. (Trigger by rising edge) 630 630 )))|OK 631 631 632 - (% style="color:blue" %)**Downlink Command: 0x06**639 +**Downlink Command: 0x06** 633 633 634 634 Format: Command Code (0x06) followed by 3 bytes. 635 635 ... ... @@ -638,15 +638,16 @@ 638 638 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 639 639 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 640 640 648 + 641 641 == 3.3 Set the output time == 642 642 643 643 644 644 Feature, Control the output 3V3 , 5V or 12V. 645 645 646 - (% style="color:blue" %)**AT Command: AT+3V3T**654 +**AT Command: AT+3V3T** 647 647 648 648 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 649 -| =(% style="width:;" %)**Command Example**|=(% style="width:;" %)**Function**|=(% style="width:;" %)**Response**657 +|(% style="width:156px" %)**Command Example**|(% style="width:236px" %)**Function**|(% style="width:117px" %)**Response** 650 650 |(% style="width:156px" %)AT+3V3T=?|(% style="width:236px" %)Show 3V3 open time.|(% style="width:117px" %)((( 651 651 0 652 652 ... ... @@ -668,10 +668,10 @@ 668 668 669 669 ))) 670 670 671 - (% style="color:blue" %)**AT Command: AT+5VT**679 +**AT Command: AT+5VT** 672 672 673 673 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 674 -| =(% style="width:;" %)**Command Example**|=(% style="width:;" %)**Function**|=(% style="width:;" %)**Response**682 +|(% style="width:158px" %)**Command Example**|(% style="width:232px" %)**Function**|(% style="width:119px" %)**Response** 675 675 |(% style="width:158px" %)AT+5VT=?|(% style="width:232px" %)Show 5V open time.|(% style="width:119px" %)((( 676 676 0 677 677 ... ... @@ -693,10 +693,10 @@ 693 693 694 694 ))) 695 695 696 - (% style="color:blue" %)**AT Command: AT+12VT**704 +**AT Command: AT+12VT** 697 697 698 698 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 699 -| =(% style="width:;" %)**Command Example**|=(% style="width:;" %)**Function**|=**Response**707 +|(% style="width:156px" %)**Command Example**|(% style="width:268px" %)**Function**|**Response** 700 700 |(% style="width:156px" %)AT+12VT=?|(% style="width:268px" %)Show 12V open time.|((( 701 701 0 702 702 ... ... @@ -709,7 +709,7 @@ 709 709 710 710 ))) 711 711 712 - (% style="color:blue" %)**Downlink Command: 0x07**720 +**Downlink Command: 0x07** 713 713 714 714 Format: Command Code (0x07) followed by 3 bytes. 715 715 ... ... @@ -722,13 +722,14 @@ 722 722 * Example 5: Downlink Payload: 070301F4 -> AT+12VT=500 723 723 * Example 6: Downlink Payload: 07030000 -> AT+12VT=0 724 724 733 + 725 725 == 3.4 Set the Probe Model == 726 726 727 727 728 - (% style="color:blue" %)**AT Command: AT** **+PROBE**737 +**AT Command: AT** **+PROBE** 729 729 730 730 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 731 -| =(% style="width:;" %)**Command Example**|=(% style="width:;" %)**Function**|=**Response**740 +|(% style="width:157px" %)**Command Example**|(% style="width:267px" %)**Function**|**Response** 732 732 |(% style="width:157px" %)AT +PROBE =?|(% style="width:267px" %)Get or Set the probe model.|((( 733 733 0 734 734 ... ... @@ -746,7 +746,7 @@ 746 746 747 747 ))) 748 748 749 - (% style="color:blue" %)**Downlink Command: 0x08**758 +**Downlink Command: 0x08** 750 750 751 751 Format: Command Code (0x08) followed by 2 bytes. 752 752 ... ... @@ -753,6 +753,7 @@ 753 753 * Example 1: Downlink Payload: 080003 -> AT+PROBE=0003 754 754 * Example 2: Downlink Payload: 080101 -> AT+PROBE=0101 755 755 765 + 756 756 = 4. Battery & how to replace = 757 757 758 758 == 4.1 Battery Type == ... ... @@ -788,12 +788,12 @@ 788 788 Instruction to use as below: 789 789 790 790 791 - (% style="color:blue" %)**Step 1:**(%%)Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:801 +**Step 1:** Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 792 792 793 793 [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]] 794 794 795 795 796 - (% style="color:blue" %)**Step 2:**(%%)Open it and choose806 +**Step 2:** Open it and choose 797 797 798 798 * Product Model 799 799 * Uplink Interval ... ... @@ -875,11 +875,11 @@ 875 875 = 9. Packing Info = 876 876 877 877 878 - (% style="color:#037691" %)**Package Includes**:888 +**Package Includes**: 879 879 880 880 * PS-LB LoRaWAN Pressure Sensor 881 881 882 - (% style="color:#037691" %)**Dimension and weight**:892 +**Dimension and weight**: 883 883 884 884 * Device Size: cm 885 885 * Device Weight: g ... ... @@ -886,11 +886,11 @@ 886 886 * Package Size / pcs : cm 887 887 * Weight / pcs : g 888 888 899 + 889 889 = 10. Support = 890 890 891 891 892 892 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 893 - 894 894 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 895 895 896 896