Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/03 14:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -581,8 +581,8 @@ 581 581 (% style="color:blue" %)**AT Command: AT+TDC** 582 582 583 583 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 584 -|**Command Example**|**Function**|**Response** 585 -|AT+TDC=?|Show current transmit Interval|((( 584 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response** 585 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|((( 586 586 30000 587 587 588 588 OK ... ... @@ -589,7 +589,7 @@ 589 589 590 590 the interval is 30000ms = 30s 591 591 ))) 592 -|AT+TDC=60000|Set Transmit Interval|((( 592 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|((( 593 593 OK 594 594 595 595 Set transmit interval to 60000ms = 60 seconds ... ... @@ -612,7 +612,7 @@ 612 612 (% style="color:blue" %)**AT Command: AT+INTMOD** 613 613 614 614 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 615 -|**Command Example**|**Function**|**Response** 615 +|=**Command Example**|=**Function**|=**Response** 616 616 |AT+INTMOD=?|Show current interrupt mode|((( 617 617 0 618 618 ... ... @@ -649,7 +649,7 @@ 649 649 (% style="color:blue" %)**AT Command: AT+3V3T** 650 650 651 651 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 652 -|(% style="width:156px" %)**Command Example**|(% style="width:236px" %)**Function**|(% style="width:117px" %)**Response** 652 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 236px;" %)**Function**|=(% style="width: 117px;" %)**Response** 653 653 |(% style="width:156px" %)AT+3V3T=?|(% style="width:236px" %)Show 3V3 open time.|(% style="width:117px" %)((( 654 654 0 655 655 ... ... @@ -674,7 +674,7 @@ 674 674 (% style="color:blue" %)**AT Command: AT+5VT** 675 675 676 676 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 677 -|(% style="width:158px" %)**Command Example**|(% style="width:232px" %)**Function**|(% style="width:119px" %)**Response** 677 +|=(% style="width: 158px;" %)**Command Example**|=(% style="width: 232px;" %)**Function**|=(% style="width: 119px;" %)**Response** 678 678 |(% style="width:158px" %)AT+5VT=?|(% style="width:232px" %)Show 5V open time.|(% style="width:119px" %)((( 679 679 0 680 680 ... ... @@ -699,7 +699,7 @@ 699 699 (% style="color:blue" %)**AT Command: AT+12VT** 700 700 701 701 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 702 -|(% style="width:156px" %)**Command Example**|(% style="width:268px" %)**Function**|**Response** 702 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 268px;" %)**Function**|=**Response** 703 703 |(% style="width:156px" %)AT+12VT=?|(% style="width:268px" %)Show 12V open time.|((( 704 704 0 705 705 ... ... @@ -731,7 +731,7 @@ 731 731 (% style="color:blue" %)**AT Command: AT** **+PROBE** 732 732 733 733 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 734 -|(% style="width:157px" %)**Command Example**|(% style="width:267px" %)**Function**|**Response** 734 +|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 267px;" %)**Function**|=**Response** 735 735 |(% style="width:157px" %)AT +PROBE =?|(% style="width:267px" %)Get or Set the probe model.|((( 736 736 0 737 737