... ... @@ -202,7 +202,6 @@
202 202  )))
203 203  |(% style="width:138px" %)Fast press ACT 5 times.|(% style="width:100px" %)Deactivate Device|red led will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.
204 204  
205 -
206 206  == 1.9 Pin Mapping ==
207 207  
208 208  
... ... @@ -560,7 +560,7 @@
560 560  
561 561  There are two kinds of commands to configure PS-LB, they are:
562 562  
563 -* **(% style="color:#037691" %)General Commands**.
562 +* (% style="color:#037691" %)**General Commands**.
564 564  
565 565  These commands are to configure:
566 566  
... ... @@ -572,7 +572,7 @@
572 572  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
573 573  
574 574  
575 -* **(% style="color:#037691" %)Commands special design for PS-LB**
574 +* (% style="color:#037691" %)**Commands special design for PS-LB**
576 576  
577 577  These commands only valid for PS-LB, as below:
578 578  
... ... @@ -582,7 +582,7 @@
582 582  
583 583  Feature: Change LoRaWAN End Node Transmit Interval.
584 584  
585 -**(% style="color:blue" %)AT Command: AT+TDC**
584 +(% style="color:blue" %)**AT Command: AT+TDC**
586 586  
587 587  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
588 588  |**Command Example**|**Function**|**Response**
... ... @@ -599,7 +599,7 @@
599 599  Set transmit interval to 60000ms = 60 seconds
600 600  )))
601 601  
602 -**(% style="color:blue" %)Downlink Command: 0x01**
601 +(% style="color:blue" %)**Downlink Command: 0x01**
603 603  
604 604  Format: Command Code (0x01) followed by 3 bytes time value.
605 605  
... ... @@ -609,13 +609,12 @@
609 609  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
610 610  
611 611  
612 -
613 613  == 3.2 Set Interrupt Mode ==
614 614  
615 615  
616 616  Feature, Set Interrupt mode for GPIO_EXIT.
617 617  
618 -**(% style="color:blue" %)AT Command: AT+INTMOD**
616 +(% style="color:blue" %)**AT Command: AT+INTMOD**
619 619  
620 620  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
621 621  |**Command Example**|**Function**|**Response**
... ... @@ -638,7 +638,7 @@
638 638  4. (Trigger by rising edge)
639 639  )))|OK
640 640  
641 -**(% style="color:blue" %)Downlink Command: 0x06**
639 +(% style="color:blue" %)**Downlink Command: 0x06**
642 642  
643 643  Format: Command Code (0x06) followed by 3 bytes.
644 644  
... ... @@ -647,13 +647,12 @@
647 647  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
648 648  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
649 649  
650 -
651 651  == 3.3 Set the output time ==
652 652  
653 653  
654 654  Feature, Control the output 3V3 , 5V or 12V.
655 655  
656 -**(% style="color:blue" %)AT Command: AT+3V3T**
653 +(% style="color:blue" %)**AT Command: AT+3V3T**
657 657  
658 658  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
659 659  |(% style="width:156px" %)**Command Example**|(% style="width:236px" %)**Function**|(% style="width:117px" %)**Response**
... ... @@ -678,7 +678,7 @@
678 678  
679 679  )))
680 680  
681 -**(% style="color:blue" %)AT Command: AT+5VT**
678 +(% style="color:blue" %)**AT Command: AT+5VT**
682 682  
683 683  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
684 684  |(% style="width:158px" %)**Command Example**|(% style="width:232px" %)**Function**|(% style="width:119px" %)**Response**
... ... @@ -703,7 +703,7 @@
703 703  
704 704  )))
705 705  
706 -**(% style="color:blue" %)AT Command: AT+12VT**
703 +(% style="color:blue" %)**AT Command: AT+12VT**
707 707  
708 708  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
709 709  |(% style="width:156px" %)**Command Example**|(% style="width:268px" %)**Function**|**Response**
... ... @@ -719,7 +719,7 @@
719 719  
720 720  )))
721 721  
722 -**(% style="color:blue" %)Downlink Command: 0x07**
719 +(% style="color:blue" %)**Downlink Command: 0x07**
723 723  
724 724  Format: Command Code (0x07) followed by 3 bytes.
725 725  
... ... @@ -732,11 +732,10 @@
732 732  * Example 5: Downlink Payload: 070301F4  -> AT+12VT=500
733 733  * Example 6: Downlink Payload: 07030000  -> AT+12VT=0
734 734  
735 -
736 736  == 3.4 Set the Probe Model ==
737 737  
738 738  
739 -**(% style="color:blue" %)AT Command: AT** **+PROBE**
735 +(% style="color:blue" %)**AT Command: AT** **+PROBE**
740 740  
741 741  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
742 742  |(% style="width:157px" %)**Command Example**|(% style="width:267px" %)**Function**|**Response**
... ... @@ -757,7 +757,7 @@
757 757  
758 758  )))
759 759  
760 -**(% style="color:blue" %)Downlink Command: 0x08**
756 +(% style="color:blue" %)**Downlink Command: 0x08**
761 761  
762 762  Format: Command Code (0x08) followed by 2 bytes.
763 763  
... ... @@ -764,7 +764,6 @@
764 764  * Example 1: Downlink Payload: 080003  -> AT+PROBE=0003
765 765  * Example 2: Downlink Payload: 080101  -> AT+PROBE=0101
766 766  
767 -
768 768  = 4. Battery & how to replace =
769 769  
770 770  == 4.1 Battery Type ==
... ... @@ -800,12 +800,12 @@
800 800  Instruction to use as below:
801 801  
802 802  
803 -**(% style="color:blue" %)Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
798 +(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
804 804  
805 805  [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]]
806 806  
807 807  
808 -**(% style="color:blue" %)Step 2:**(%%) Open it and choose
803 +(% style="color:blue" %)**Step 2:**(%%) Open it and choose
809 809  
810 810  * Product Model
811 811  * Uplink Interval
... ... @@ -887,11 +887,11 @@
887 887  = 9. ​Packing Info =
888 888  
889 889  
890 -**(% style="color:#037691" %)Package Includes**:
885 +(% style="color:#037691" %)**Package Includes**:
891 891  
892 892  * PS-LB LoRaWAN Pressure Sensor
893 893  
894 -**(% style="color:#037691" %)Dimension and weight**:
889 +(% style="color:#037691" %)**Dimension and weight**:
895 895  
896 896  * Device Size: cm
897 897  * Device Weight: g
... ... @@ -898,7 +898,6 @@
898 898  * Package Size / pcs : cm
899 899  * Weight / pcs : g
900 900  
901 -
902 902  = 10. Support =
903 903  
904 904  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved