Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/03 14:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -202,7 +202,6 @@ 202 202 ))) 203 203 |(% style="width:138px" %)Fast press ACT 5 times.|(% style="width:100px" %)Deactivate Device|red led will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 204 204 205 - 206 206 == 1.9 Pin Mapping == 207 207 208 208 ... ... @@ -560,7 +560,7 @@ 560 560 561 561 There are two kinds of commands to configure PS-LB, they are: 562 562 563 -* **(% style="color:#037691" %)General Commands**.562 +* (% style="color:#037691" %)**General Commands**. 564 564 565 565 These commands are to configure: 566 566 ... ... @@ -572,7 +572,7 @@ 572 572 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 573 573 574 574 575 -* **(% style="color:#037691" %)Commands special design for PS-LB**574 +* (% style="color:#037691" %)**Commands special design for PS-LB** 576 576 577 577 These commands only valid for PS-LB, as below: 578 578 ... ... @@ -582,7 +582,7 @@ 582 582 583 583 Feature: Change LoRaWAN End Node Transmit Interval. 584 584 585 - **(% style="color:blue" %)AT Command: AT+TDC**584 +(% style="color:blue" %)**AT Command: AT+TDC** 586 586 587 587 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 588 588 |**Command Example**|**Function**|**Response** ... ... @@ -599,7 +599,7 @@ 599 599 Set transmit interval to 60000ms = 60 seconds 600 600 ))) 601 601 602 - **(% style="color:blue" %)Downlink Command: 0x01**601 +(% style="color:blue" %)**Downlink Command: 0x01** 603 603 604 604 Format: Command Code (0x01) followed by 3 bytes time value. 605 605 ... ... @@ -609,13 +609,12 @@ 609 609 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 610 610 611 611 612 - 613 613 == 3.2 Set Interrupt Mode == 614 614 615 615 616 616 Feature, Set Interrupt mode for GPIO_EXIT. 617 617 618 - **(% style="color:blue" %)AT Command: AT+INTMOD**616 +(% style="color:blue" %)**AT Command: AT+INTMOD** 619 619 620 620 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 621 621 |**Command Example**|**Function**|**Response** ... ... @@ -638,7 +638,7 @@ 638 638 4. (Trigger by rising edge) 639 639 )))|OK 640 640 641 - **(% style="color:blue" %)Downlink Command: 0x06**639 +(% style="color:blue" %)**Downlink Command: 0x06** 642 642 643 643 Format: Command Code (0x06) followed by 3 bytes. 644 644 ... ... @@ -647,13 +647,12 @@ 647 647 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 648 648 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 649 649 650 - 651 651 == 3.3 Set the output time == 652 652 653 653 654 654 Feature, Control the output 3V3 , 5V or 12V. 655 655 656 - **(% style="color:blue" %)AT Command: AT+3V3T**653 +(% style="color:blue" %)**AT Command: AT+3V3T** 657 657 658 658 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 659 659 |(% style="width:156px" %)**Command Example**|(% style="width:236px" %)**Function**|(% style="width:117px" %)**Response** ... ... @@ -678,7 +678,7 @@ 678 678 679 679 ))) 680 680 681 - **(% style="color:blue" %)AT Command: AT+5VT**678 +(% style="color:blue" %)**AT Command: AT+5VT** 682 682 683 683 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 684 684 |(% style="width:158px" %)**Command Example**|(% style="width:232px" %)**Function**|(% style="width:119px" %)**Response** ... ... @@ -703,7 +703,7 @@ 703 703 704 704 ))) 705 705 706 - **(% style="color:blue" %)AT Command: AT+12VT**703 +(% style="color:blue" %)**AT Command: AT+12VT** 707 707 708 708 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 709 709 |(% style="width:156px" %)**Command Example**|(% style="width:268px" %)**Function**|**Response** ... ... @@ -719,7 +719,7 @@ 719 719 720 720 ))) 721 721 722 - **(% style="color:blue" %)Downlink Command: 0x07**719 +(% style="color:blue" %)**Downlink Command: 0x07** 723 723 724 724 Format: Command Code (0x07) followed by 3 bytes. 725 725 ... ... @@ -732,11 +732,10 @@ 732 732 * Example 5: Downlink Payload: 070301F4 -> AT+12VT=500 733 733 * Example 6: Downlink Payload: 07030000 -> AT+12VT=0 734 734 735 - 736 736 == 3.4 Set the Probe Model == 737 737 738 738 739 - **(% style="color:blue" %)AT Command: AT** **+PROBE**735 +(% style="color:blue" %)**AT Command: AT** **+PROBE** 740 740 741 741 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 742 742 |(% style="width:157px" %)**Command Example**|(% style="width:267px" %)**Function**|**Response** ... ... @@ -757,7 +757,7 @@ 757 757 758 758 ))) 759 759 760 - **(% style="color:blue" %)Downlink Command: 0x08**756 +(% style="color:blue" %)**Downlink Command: 0x08** 761 761 762 762 Format: Command Code (0x08) followed by 2 bytes. 763 763 ... ... @@ -764,7 +764,6 @@ 764 764 * Example 1: Downlink Payload: 080003 -> AT+PROBE=0003 765 765 * Example 2: Downlink Payload: 080101 -> AT+PROBE=0101 766 766 767 - 768 768 = 4. Battery & how to replace = 769 769 770 770 == 4.1 Battery Type == ... ... @@ -800,12 +800,12 @@ 800 800 Instruction to use as below: 801 801 802 802 803 - **(% style="color:blue" %)Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:798 +(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 804 804 805 805 [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]] 806 806 807 807 808 - **(% style="color:blue" %)Step 2:**(%%) Open it and choose803 +(% style="color:blue" %)**Step 2:**(%%) Open it and choose 809 809 810 810 * Product Model 811 811 * Uplink Interval ... ... @@ -887,11 +887,11 @@ 887 887 = 9. Packing Info = 888 888 889 889 890 - **(% style="color:#037691" %)Package Includes**:885 +(% style="color:#037691" %)**Package Includes**: 891 891 892 892 * PS-LB LoRaWAN Pressure Sensor 893 893 894 - **(% style="color:#037691" %)Dimension and weight**:889 +(% style="color:#037691" %)**Dimension and weight**: 895 895 896 896 * Device Size: cm 897 897 * Device Weight: g ... ... @@ -898,7 +898,6 @@ 898 898 * Package Size / pcs : cm 899 899 * Weight / pcs : g 900 900 901 - 902 902 = 10. Support = 903 903 904 904