... ... @@ -582,7 +582,7 @@
582 582  
583 583  Feature: Change LoRaWAN End Node Transmit Interval.
584 584  
585 -**(% style="color:blue" %)AT Command: AT+TDC**
585 +**AT Command: AT+TDC**
586 586  
587 587  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
588 588  |**Command Example**|**Function**|**Response**
... ... @@ -599,7 +599,7 @@
599 599  Set transmit interval to 60000ms = 60 seconds
600 600  )))
601 601  
602 -**(% style="color:blue" %)Downlink Command: 0x01**
602 +**Downlink Command: 0x01**
603 603  
604 604  Format: Command Code (0x01) followed by 3 bytes time value.
605 605  
... ... @@ -608,14 +608,12 @@
608 608  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
609 609  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
610 610  
611 -
612 -
613 613  == 3.2 Set Interrupt Mode ==
614 614  
615 615  
616 616  Feature, Set Interrupt mode for GPIO_EXIT.
617 617  
618 -**(% style="color:blue" %)AT Command: AT+INTMOD**
616 +**AT Command: AT+INTMOD**
619 619  
620 620  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
621 621  |**Command Example**|**Function**|**Response**
... ... @@ -638,7 +638,7 @@
638 638  4. (Trigger by rising edge)
639 639  )))|OK
640 640  
641 -**(% style="color:blue" %)Downlink Command: 0x06**
639 +**Downlink Command: 0x06**
642 642  
643 643  Format: Command Code (0x06) followed by 3 bytes.
644 644  
... ... @@ -653,7 +653,7 @@
653 653  
654 654  Feature, Control the output 3V3 , 5V or 12V.
655 655  
656 -**(% style="color:blue" %)AT Command: AT+3V3T**
654 +**AT Command: AT+3V3T**
657 657  
658 658  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
659 659  |(% style="width:156px" %)**Command Example**|(% style="width:236px" %)**Function**|(% style="width:117px" %)**Response**
... ... @@ -678,7 +678,7 @@
678 678  
679 679  )))
680 680  
681 -**(% style="color:blue" %)AT Command: AT+5VT**
679 +**AT Command: AT+5VT**
682 682  
683 683  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
684 684  |(% style="width:158px" %)**Command Example**|(% style="width:232px" %)**Function**|(% style="width:119px" %)**Response**
... ... @@ -703,7 +703,7 @@
703 703  
704 704  )))
705 705  
706 -**(% style="color:blue" %)AT Command: AT+12VT**
704 +**AT Command: AT+12VT**
707 707  
708 708  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
709 709  |(% style="width:156px" %)**Command Example**|(% style="width:268px" %)**Function**|**Response**
... ... @@ -719,7 +719,7 @@
719 719  
720 720  )))
721 721  
722 -**(% style="color:blue" %)Downlink Command: 0x07**
720 +**Downlink Command: 0x07**
723 723  
724 724  Format: Command Code (0x07) followed by 3 bytes.
725 725  
... ... @@ -736,7 +736,7 @@
736 736  == 3.4 Set the Probe Model ==
737 737  
738 738  
739 -**(% style="color:blue" %)AT Command: AT** **+PROBE**
737 +**AT Command: AT** **+PROBE**
740 740  
741 741  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
742 742  |(% style="width:157px" %)**Command Example**|(% style="width:267px" %)**Function**|**Response**
... ... @@ -757,7 +757,7 @@
757 757  
758 758  )))
759 759  
760 -**(% style="color:blue" %)Downlink Command: 0x08**
758 +**Downlink Command: 0x08**
761 761  
762 762  Format: Command Code (0x08) followed by 2 bytes.