190 -|(% style="width:138px" %)**Behavior on ACT**|(% style="width:100px" %)**Function**|**Action**
191 -|(% style="width:138px" %)Pressing ACT between 1s < time < 3s|(% style="width:100px" %)Send an uplink|(((
190 +|=(% style="width: 150px;" %)**Behavior on ACT**|=(% style="width: 90px;" %)**Function**|=**Action**
191 +|(% style="width:260px" %)Pressing ACT between 1s < time < 3s|(% style="width:100px" %)Send an uplink|(((
192 192  If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once.
193 -
194 194  Meanwhile, BLE module will be active and user can connect via BLE to configure device.
195 195  )))
196 196  |(% style="width:138px" %)Pressing ACT for more than 3s|(% style="width:100px" %)Active Device|(((
197 197  (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network.
198 -
199 199  (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
200 -
201 201  Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network.
202 202  )))
203 203  |(% style="width:138px" %)Fast press ACT 5 times.|(% style="width:100px" %)Deactivate Device|red led will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.
204 204  
205 -
206 206  == 1.9 Pin Mapping ==
207 207  
208 208  
... ... @@ -392,8 +392,8 @@
392 392  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
393 393  |(% style="width:97px" %)(((
394 394  **Size(bytes)**
395 -)))|(% style="width:48px" %)**2**|(% style="width:58px" %)**2**|**2**|**2**|**1**
396 -|(% style="width:97px" %)**Value**|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:58px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|[[IN1 &IN2 Interrupt  flag>>||anchor="H2.3.7IN126IN226INTpin"]]
391 +)))|(% style="width:48px" %)**2**|(% style="width:71px" %)**2**|(% style="width:98px" %)**2**|(% style="width:73px" %)**2**|(% style="width:122px" %)**1**
392 +|(% style="width:97px" %)**Value**|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt  flag>>||anchor="H2.3.7IN126IN226INTpin"]]
397 397  
398 398  [[image:1675144608950-310.png]]
399 399  
... ... @@ -505,7 +505,7 @@
505 505  
506 506  (% style="color:blue" %)**Step 3:**(%%) Create an account or log in Datacake.
507 507  
508 -(% style="color:#blue" %)**Step 4:** (%%)Create PS-LB product.
504 +(% style="color:blue" %)**Step 4:** (%%)Create PS-LB product.
509 509  
510 510  [[image:1675145004465-869.png]]
511 511  
... ... @@ -555,12 +555,12 @@
555 555  
556 556  Use can configure PS-LB via AT Command or LoRaWAN Downlink.
557 557  
558 -* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
554 +* AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]].
559 559  * LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
560 560  
561 561  There are two kinds of commands to configure PS-LB, they are:
562 562  
563 -* **General Commands**.
559 +* (% style="color:#037691" %)**General Commands**.
564 564  
565 565  These commands are to configure:
566 566  
... ... @@ -572,7 +572,7 @@
572 572  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
573 573  
574 574  
575 -* **Commands special design for PS-LB**
571 +* (% style="color:#037691" %)**Commands special design for PS-LB**
576 576  
577 577  These commands only valid for PS-LB, as below:
578 578  
... ... @@ -582,24 +582,21 @@
582 582  
583 583  Feature: Change LoRaWAN End Node Transmit Interval.
584 584  
585 -**AT Command: AT+TDC**
581 +(% style="color:blue" %)**AT Command: AT+TDC**
586 586  
587 587  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
588 -|**Command Example**|**Function**|**Response**
589 -|AT+TDC=?|Show current transmit Interval|(((
584 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response**
585 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|(((
590 590  30000
591 -
592 592  OK
593 -
594 594  the interval is 30000ms = 30s
595 595  )))
596 -|AT+TDC=60000|Set Transmit Interval|(((
590 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|(((
597 597  OK
598 -
599 599  Set transmit interval to 60000ms = 60 seconds
600 600  )))
601 601  
602 -**Downlink Command: 0x01**
595 +(% style="color:blue" %)**Downlink Command: 0x01**
603 603  
604 604  Format: Command Code (0x01) followed by 3 bytes time value.
605 605  
... ... @@ -613,30 +613,24 @@
613 613  
614 614  Feature, Set Interrupt mode for GPIO_EXIT.
615 615  
616 -**AT Command: AT+INTMOD**
609 +(% style="color:blue" %)**AT Command: AT+INTMOD**
617 617  
618 618  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
619 -|**Command Example**|**Function**|**Response**
612 +|=**Command Example**|=**Function**|=**Response**
620 620  |AT+INTMOD=?|Show current interrupt mode|(((
621 621  0
622 -
623 623  OK
624 -
625 625  the mode is 0 = No interruption
626 626  )))
627 627  |AT+INTMOD=2|(((
628 628  Set Transmit Interval
629 -
630 630  ~1. (Disable Interrupt),
631 -
632 632  2. (Trigger by rising and falling edge),
633 -
634 634  3. (Trigger by falling edge)
635 -
636 636  4. (Trigger by rising edge)
637 637  )))|OK
638 638  
639 -**Downlink Command: 0x06**
626 +(% style="color:blue" %)**Downlink Command: 0x06**
640 640  
641 641  Format: Command Code (0x06) followed by 3 bytes.
642 642  
... ... @@ -645,79 +645,63 @@
645 645  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
646 646  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
647 647  
648 -
649 649  == 3.3 Set the output time ==
650 650  
651 651  
652 652  Feature, Control the output 3V3 , 5V or 12V.
653 653  
654 -**AT Command: AT+3V3T**
640 +(% style="color:blue" %)**AT Command: AT+3V3T**
655 655  
656 656  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
657 -|(% style="width:156px" %)**Command Example**|(% style="width:236px" %)**Function**|(% style="width:117px" %)**Response**
643 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 236px;" %)**Function**|=(% style="width: 117px;" %)**Response**
658 658  |(% style="width:156px" %)AT+3V3T=?|(% style="width:236px" %)Show 3V3 open time.|(% style="width:117px" %)(((
659 659  0
660 -
661 661  OK
662 662  )))
663 663  |(% style="width:156px" %)AT+3V3T=0|(% style="width:236px" %)Normally open 3V3 power supply.|(% style="width:117px" %)(((
664 664  OK
665 -
666 666  default setting
667 667  )))
668 668  |(% style="width:156px" %)AT+3V3T=1000|(% style="width:236px" %)Close after a delay of 1000 milliseconds.|(% style="width:117px" %)(((
669 669  OK
670 -
671 -
672 672  )))
673 673  |(% style="width:156px" %)AT+3V3T=65535|(% style="width:236px" %)Normally closed 3V3 power supply.|(% style="width:117px" %)(((
674 674  OK
675 -
676 -
677 677  )))
678 678  
679 -**AT Command: AT+5VT**
659 +(% style="color:blue" %)**AT Command: AT+5VT**
680 680  
681 681  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
682 -|(% style="width:158px" %)**Command Example**|(% style="width:232px" %)**Function**|(% style="width:119px" %)**Response**
662 +|=(% style="width: 158px;" %)**Command Example**|=(% style="width: 232px;" %)**Function**|=(% style="width: 119px;" %)**Response**
683 683  |(% style="width:158px" %)AT+5VT=?|(% style="width:232px" %)Show 5V open time.|(% style="width:119px" %)(((
684 684  0
685 -
686 686  OK
687 687  )))
688 688  |(% style="width:158px" %)AT+5VT=0|(% style="width:232px" %)Normally closed 5V power supply.|(% style="width:119px" %)(((
689 689  OK
690 -
691 691  default setting
692 692  )))
693 693  |(% style="width:158px" %)AT+5VT=1000|(% style="width:232px" %)Close after a delay of 1000 milliseconds.|(% style="width:119px" %)(((
694 694  OK
695 -
696 -
697 697  )))
698 698  |(% style="width:158px" %)AT+5VT=65535|(% style="width:232px" %)Normally open 5V power supply.|(% style="width:119px" %)(((
699 699  OK
700 -
701 -
702 702  )))
703 703  
704 -**AT Command: AT+12VT**
678 +(% style="color:blue" %)**AT Command: AT+12VT**
705 705  
706 706  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
707 -|(% style="width:156px" %)**Command Example**|(% style="width:268px" %)**Function**|**Response**
681 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 268px;" %)**Function**|=**Response**
708 708  |(% style="width:156px" %)AT+12VT=?|(% style="width:268px" %)Show 12V open time.|(((
709 709  0
710 -
711 711  OK
712 712  )))
713 713  |(% style="width:156px" %)AT+12VT=0|(% style="width:268px" %)Normally closed 12V power supply.|OK
714 714  |(% style="width:156px" %)AT+12VT=500|(% style="width:268px" %)Close after a delay of 500 milliseconds.|(((
715 715  OK
716 -
717 -
718 718  )))
719 719  
720 -**Downlink Command: 0x07**
691 +(% style="color:blue" %)**Downlink Command: 0x07**
721 721  
722 722  Format: Command Code (0x07) followed by 3 bytes.
723 723  
... ... @@ -730,32 +730,26 @@
730 730  * Example 5: Downlink Payload: 070301F4  -> AT+12VT=500
731 731  * Example 6: Downlink Payload: 07030000  -> AT+12VT=0
732 732  
733 -
734 734  == 3.4 Set the Probe Model ==
735 735  
736 736  
737 -**AT Command: AT** **+PROBE**
707 +(% style="color:blue" %)**AT Command: AT** **+PROBE**
738 738  
739 739  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
740 -|(% style="width:157px" %)**Command Example**|(% style="width:267px" %)**Function**|**Response**
710 +|=(% style="width: 157px;" %)**Command Example**|=(% style="width: 267px;" %)**Function**|=**Response**
741 741  |(% style="width:157px" %)AT +PROBE =?|(% style="width:267px" %)Get or Set the probe model.|(((
742 742  0
743 -
744 744  OK
745 745  )))
746 746  |(% style="width:157px" %)AT +PROBE =0003|(% style="width:267px" %)Set water depth sensor mode, 3m type.|OK
747 747  |(% style="width:157px" %)AT +PROBE =0101|(% style="width:267px" %)Set pressure transmitters mode, first type.|(((
748 748  OK
749 -
750 -
751 751  )))
752 752  |(% style="width:157px" %)AT +PROBE =0000|(% style="width:267px" %)Initial state, no settings.|(((
753 753  OK
754 -
755 -
756 756  )))
757 757  
758 -**Downlink Command: 0x08**
723 +(% style="color:blue" %)**Downlink Command: 0x08**
759 759  
760 760  Format: Command Code (0x08) followed by 2 bytes.
761 761  
... ... @@ -762,7 +762,6 @@
762 762  * Example 1: Downlink Payload: 080003  -> AT+PROBE=0003
763 763  * Example 2: Downlink Payload: 080101  -> AT+PROBE=0101
764 764  
765 -
766 766  = 4. Battery & how to replace =
767 767  
768 768  == 4.1 Battery Type ==
... ... @@ -798,12 +798,12 @@
798 798  Instruction to use as below:
799 799  
800 800  
801 -**Step 1:** Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
765 +(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
802 802  
803 803  [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]]
804 804  
805 805  
806 -**Step 2:** Open it and choose
770 +(% style="color:blue" %)**Step 2:**(%%) Open it and choose
807 807  
808 808  * Product Model
809 809  * Uplink Interval
... ... @@ -885,11 +885,11 @@
885 885  = 9. ​Packing Info =
886 886  
887 887  
888 -**Package Includes**:
852 +(% style="color:#037691" %)**Package Includes**:
889 889  
890 890  * PS-LB LoRaWAN Pressure Sensor
891 891  
892 -**Dimension and weight**:
856 +(% style="color:#037691" %)**Dimension and weight**:
893 893  
894 894  * Device Size: cm
895 895  * Device Weight: g
... ... @@ -896,11 +896,11 @@
896 896  * Package Size / pcs : cm
897 897  * Weight / pcs : g
898 898  
899 -
900 900  = 10. Support =
901 901  
902 902  
903 903  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
867 +
904 904  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
905 905  
906 906  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0