From version < 42.17 >
edited by Xiaoling
on 2023/01/31 16:12
To version < 42.19 >
edited by Xiaoling
on 2023/01/31 16:17
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -505,7 +505,7 @@
505 505  
506 506  (% style="color:blue" %)**Step 3:**(%%) Create an account or log in Datacake.
507 507  
508 -(% style="color:#blue" %)**Step 4:** (%%)Create PS-LB product.
508 +(% style="color:blue" %)**Step 4:** (%%)Create PS-LB product.
509 509  
510 510  [[image:1675145004465-869.png]]
511 511  
... ... @@ -555,12 +555,12 @@
555 555  
556 556  Use can configure PS-LB via AT Command or LoRaWAN Downlink.
557 557  
558 -* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
558 +* AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]].
559 559  * LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
560 560  
561 561  There are two kinds of commands to configure PS-LB, they are:
562 562  
563 -* **General Commands**.
563 +* **(% style="color:#037691" %)General Commands**.
564 564  
565 565  These commands are to configure:
566 566  
... ... @@ -572,7 +572,7 @@
572 572  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
573 573  
574 574  
575 -* **Commands special design for PS-LB**
575 +* **(% style="color:#037691" %)Commands special design for PS-LB**
576 576  
577 577  These commands only valid for PS-LB, as below:
578 578  
... ... @@ -582,7 +582,7 @@
582 582  
583 583  Feature: Change LoRaWAN End Node Transmit Interval.
584 584  
585 -**AT Command: AT+TDC**
585 +**(% style="color:blue" %)AT Command: AT+TDC**
586 586  
587 587  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
588 588  |**Command Example**|**Function**|**Response**
... ... @@ -599,7 +599,7 @@
599 599  Set transmit interval to 60000ms = 60 seconds
600 600  )))
601 601  
602 -**Downlink Command: 0x01**
602 +**(% style="color:blue" %)Downlink Command: 0x01**
603 603  
604 604  Format: Command Code (0x01) followed by 3 bytes time value.
605 605  
... ... @@ -608,12 +608,14 @@
608 608  * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
609 609  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
610 610  
611 +
612 +
611 611  == 3.2 Set Interrupt Mode ==
612 612  
613 613  
614 614  Feature, Set Interrupt mode for GPIO_EXIT.
615 615  
616 -**AT Command: AT+INTMOD**
618 +**(% style="color:blue" %)AT Command: AT+INTMOD**
617 617  
618 618  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
619 619  |**Command Example**|**Function**|**Response**
... ... @@ -636,7 +636,7 @@
636 636  4. (Trigger by rising edge)
637 637  )))|OK
638 638  
639 -**Downlink Command: 0x06**
641 +**(% style="color:blue" %)Downlink Command: 0x06**
640 640  
641 641  Format: Command Code (0x06) followed by 3 bytes.
642 642  
... ... @@ -651,7 +651,7 @@
651 651  
652 652  Feature, Control the output 3V3 , 5V or 12V.
653 653  
654 -**AT Command: AT+3V3T**
656 +**(% style="color:blue" %)AT Command: AT+3V3T**
655 655  
656 656  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
657 657  |(% style="width:156px" %)**Command Example**|(% style="width:236px" %)**Function**|(% style="width:117px" %)**Response**
... ... @@ -676,7 +676,7 @@
676 676  
677 677  )))
678 678  
679 -**AT Command: AT+5VT**
681 +**(% style="color:blue" %)AT Command: AT+5VT**
680 680  
681 681  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
682 682  |(% style="width:158px" %)**Command Example**|(% style="width:232px" %)**Function**|(% style="width:119px" %)**Response**
... ... @@ -701,7 +701,7 @@
701 701  
702 702  )))
703 703  
704 -**AT Command: AT+12VT**
706 +**(% style="color:blue" %)AT Command: AT+12VT**
705 705  
706 706  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
707 707  |(% style="width:156px" %)**Command Example**|(% style="width:268px" %)**Function**|**Response**
... ... @@ -717,7 +717,7 @@
717 717  
718 718  )))
719 719  
720 -**Downlink Command: 0x07**
722 +**(% style="color:blue" %)Downlink Command: 0x07**
721 721  
722 722  Format: Command Code (0x07) followed by 3 bytes.
723 723  
... ... @@ -734,7 +734,7 @@
734 734  == 3.4 Set the Probe Model ==
735 735  
736 736  
737 -**AT Command: AT** **+PROBE**
739 +**(% style="color:blue" %)AT Command: AT** **+PROBE**
738 738  
739 739  (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
740 740  |(% style="width:157px" %)**Command Example**|(% style="width:267px" %)**Function**|**Response**
... ... @@ -755,7 +755,7 @@
755 755  
756 756  )))
757 757  
758 -**Downlink Command: 0x08**
760 +**(% style="color:blue" %)Downlink Command: 0x08**
759 759  
760 760  Format: Command Code (0x08) followed by 2 bytes.
761 761  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0