Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -335,11 +335,11 @@ 335 335 [[image:1675144504430-490.png]] 336 336 337 337 338 -** (% style="color:#037691" %)Sensor Model**(%%): For PS-LB, this value is 0x16338 +**Sensor Model**: For PS-LB, this value is 0x16 339 339 340 -** (% style="color:#037691" %)Firmware Version**(%%): 0x0100, Means: v1.0.0 version340 +**Firmware Version**: 0x0100, Means: v1.0.0 version 341 341 342 -** (% style="color:#037691" %)Frequency Band**:342 +**Frequency Band**: 343 343 344 344 *0x01: EU868 345 345 ... ... @@ -370,7 +370,7 @@ 370 370 *0x0e: MA869 371 371 372 372 373 -** (% style="color:#037691" %)Sub-Band**:373 +**Sub-Band**: 374 374 375 375 AU915 and US915:value 0x00 ~~ 0x08 376 376 ... ... @@ -379,7 +379,7 @@ 379 379 Other Bands: Always 0x00 380 380 381 381 382 -** (% style="color:#037691" %)Battery Info**:382 +**Battery Info**: 383 383 384 384 Check the battery voltage. 385 385 ... ... @@ -388,7 +388,7 @@ 388 388 Ex2: 0x0B49 = 2889mV 389 389 390 390 391 -=== 2.3.2 Sensor value, FPORT~=2 ===391 +=== 1.3.2 Sensor value, FPORT~=2 === 392 392 393 393 394 394 Uplink payload includes in total 9 bytes. ... ... @@ -398,7 +398,7 @@ 398 398 |(% style="width:97px" %)((( 399 399 **Size(bytes)** 400 400 )))|(% style="width:48px" %)**2**|(% style="width:58px" %)**2**|**2**|**2**|**1** 401 -|(% style="width:97px" %)**Value**|(% style="width:48px" %)[[BAT>> ||anchor="H2.3.3BatteryInfo"]]|(% style="width:58px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|[[0 ~~~~20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.7IN126IN226INTpin"]]401 +|(% style="width:97px" %)**Value**|(% style="width:48px" %)[[BAT>>path:#bat]]|(% style="width:58px" %)[[Probe Model>>path:#Probe_Model]]|0 ~~ 20mA value|[[0 ~~~~ 30v value>>path:#Voltage_30v]]|[[IN1 &IN2 Interrupt flag>>path:#Int_pin]] 402 402 403 403 [[image:1675144608950-310.png]] 404 404 ... ... @@ -435,7 +435,7 @@ 435 435 436 436 The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level. 437 437 438 -** (% style="color:#037691" %)Example**:438 +**Example**: 439 439 440 440 27AE(H) = 10158 (D)/1000 = 10.158mA. 441 441 ... ... @@ -445,7 +445,7 @@ 445 445 446 446 Measure the voltage value. The range is 0 to 30V. 447 447 448 -** (% style="color:#037691" %)Example**:448 +**Example**: 449 449 450 450 138E(H) = 5006(D)/1000= 5.006V 451 451 ... ... @@ -455,7 +455,7 @@ 455 455 456 456 IN1 and IN2 are used as digital input pins. 457 457 458 -** (% style="color:#037691" %)Example**:458 +**Example**: 459 459 460 460 09 (H) :(0x09&0x08)>>3=1 IN1 pin is high level. 461 461 ... ... @@ -464,7 +464,7 @@ 464 464 465 465 This data field shows if this packet is generated by **Interrupt Pin** or not. [[Click here>>path:#Int_mod]] for the hardware and software set up. Note: The Internet Pin is a separate pin in the screw terminal. 466 466 467 -** (% style="color:#037691" %)Example:**467 +**Example:** 468 468 469 469 09 (H) : (0x09&0x02)>>1=1 The level of the interrupt pin. 470 470 ... ... @@ -497,9 +497,9 @@ 497 497 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 498 498 499 499 500 -** (% style="color:blue" %)Step 1: **(%%)Be sure that your device is programmed and properly connected to the network at this time.500 +**Step 1: **Be sure that your device is programmed and properly connected to the network at this time. 501 501 502 -** (% style="color:blue" %)Step 2:**(%%)To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:502 +**Step 2:** To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps: 503 503 504 504 505 505 [[image:1675144951092-237.png]] ... ... @@ -508,9 +508,9 @@ 508 508 [[image:1675144960452-126.png]] 509 509 510 510 511 -** (% style="color:blue" %)Step 3:**(%%)Create an account or log in Datacake.511 +**Step 3:** Create an account or log in Datacake. 512 512 513 -** (% style="color:#blue" %)Step 4:**(%%)Create PS-LB product.513 +**Step 4:** Create PS-LB product. 514 514 515 515 [[image:1675145004465-869.png]] 516 516 ... ... @@ -523,7 +523,7 @@ 523 523 [[image:1675145029119-717.png]] 524 524 525 525 526 -** (% style="color:blue" %)Step 5: **(%%)add payload decode526 +**Step 5: **add payload decode 527 527 528 528 [[image:1675145051360-659.png]] 529 529