582 582  
583 583  They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
584 584  
585 -[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]]
585 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
586 586  
587 587  
588 588  * **Commands special design for PS-LB**
... ... @@ -590,13 +590,14 @@
590 590  These commands only valid for PS-LB, as below:
591 591  
592 592  
593 -1.
594 -11. Set Transmit Interval Time
593 +== 3.1 Set Transmit Interval Time ==
595 595  
595 +
596 596  Feature: Change LoRaWAN End Node Transmit Interval.
597 597  
598 598  **AT Command: AT+TDC**
599 599  
600 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
600 600  |**Command Example**|**Function**|**Response**
601 601  |AT+TDC=?|Show current transmit Interval|(((
602 602  30000
... ... @@ -621,13 +621,14 @@
621 621  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
622 622  
623 623  
624 -1.
625 -11. Set Interrupt Mode
625 +== 3.2 Set Interrupt Mode ==
626 626  
627 +
627 627  Feature, Set Interrupt mode for GPIO_EXIT.
628 628  
629 629  **AT Command: AT+INTMOD**
630 630  
632 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
631 631  |**Command Example**|**Function**|**Response**
632 632  |AT+INTMOD=?|Show current interrupt mode|(((
633 633  0
... ... @@ -639,10 +639,13 @@
639 639  |AT+INTMOD=2|(((
640 640  Set Transmit Interval
641 641  
642 -1. (Disable Interrupt),
643 -1. (Trigger by rising and falling edge),
644 -1. (Trigger by falling edge)
645 -1. (Trigger by rising edge)
644 +~1. (Disable Interrupt),
645 +
646 +2. (Trigger by rising and falling edge),
647 +
648 +3. (Trigger by falling edge)
649 +
650 +4. (Trigger by rising edge)
646 646  )))|OK
647 647  
648 648  **Downlink Command: 0x06**
... ... @@ -654,74 +654,82 @@
654 654  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
655 655  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
656 656  
657 -1.
658 -11. Set the output time
659 659  
663 +
664 +== 3.3 Set the output time ==
665 +
666 +
660 660  Feature, Control the output 3V3 , 5V or 12V.
661 661  
662 662  **AT Command: AT+3V3T**
663 663  
664 -|**Command Example**|**Function**|**Response**
665 -|AT+3V3T=?|Show 3V3 open time.|(((
671 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
672 +|(% style="width:156px" %)**Command Example**|(% style="width:236px" %)**Function**|(% style="width:117px" %)**Response**
673 +|(% style="width:156px" %)AT+3V3T=?|(% style="width:236px" %)Show 3V3 open time.|(% style="width:117px" %)(((
666 666  0
667 667  
668 668  OK
669 669  )))
670 -|AT+3V3T=0|Normally open 3V3 power supply.|(((
678 +|(% style="width:156px" %)AT+3V3T=0|(% style="width:236px" %)Normally open 3V3 power supply.|(% style="width:117px" %)(((
671 671  OK
672 672  
673 673  default setting
674 674  )))
675 -|AT+3V3T=1000|Close after a delay of 1000 milliseconds.|(((
683 +|(% style="width:156px" %)AT+3V3T=1000|(% style="width:236px" %)Close after a delay of 1000 milliseconds.|(% style="width:117px" %)(((
676 676  OK
677 677  
678 678  
679 679  )))
680 -|AT+3V3T=65535|Normally closed 3V3 power supply.|(((
688 +|(% style="width:156px" %)AT+3V3T=65535|(% style="width:236px" %)Normally closed 3V3 power supply.|(% style="width:117px" %)(((
681 681  OK
682 682  
683 683  
684 684  )))
685 685  
694 +
686 686  **AT Command: AT+5VT**
687 687  
688 -|**Command Example**|**Function**|**Response**
689 -|AT+5VT=?|Show 5V open time.|(((
697 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
698 +|(% style="width:158px" %)**Command Example**|(% style="width:232px" %)**Function**|(% style="width:119px" %)**Response**
699 +|(% style="width:158px" %)AT+5VT=?|(% style="width:232px" %)Show 5V open time.|(% style="width:119px" %)(((
690 690  0
691 691  
692 692  OK
693 693  )))
694 -|AT+5VT=0|Normally closed 5V power supply.|(((
704 +|(% style="width:158px" %)AT+5VT=0|(% style="width:232px" %)Normally closed 5V power supply.|(% style="width:119px" %)(((
695 695  OK
696 696  
697 697  default setting
698 698  )))
699 -|AT+5VT=1000|Close after a delay of 1000 milliseconds.|(((
709 +|(% style="width:158px" %)AT+5VT=1000|(% style="width:232px" %)Close after a delay of 1000 milliseconds.|(% style="width:119px" %)(((
700 700  OK
701 701  
702 702  
703 703  )))
704 -|AT+5VT=65535|Normally open 5V power supply.|(((
714 +|(% style="width:158px" %)AT+5VT=65535|(% style="width:232px" %)Normally open 5V power supply.|(% style="width:119px" %)(((
705 705  OK
706 706  
707 707  
708 708  )))
709 709  
720 +
710 710  **AT Command: AT+12VT**
711 711  
712 -|**Command Example**|**Function**|**Response**
713 -|AT+12VT=?|Show 12V open time.|(((
723 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
724 +|(% style="width:156px" %)**Command Example**|(% style="width:268px" %)**Function**|**Response**
725 +|(% style="width:156px" %)AT+12VT=?|(% style="width:268px" %)Show 12V open time.|(((
714 714  0
715 715  
716 716  OK
717 717  )))
718 -|AT+12VT=0|Normally closed 12V power supply.|OK
719 -|AT+12VT=500|Close after a delay of 500 milliseconds.|(((
730 +|(% style="width:156px" %)AT+12VT=0|(% style="width:268px" %)Normally closed 12V power supply.|OK
731 +|(% style="width:156px" %)AT+12VT=500|(% style="width:268px" %)Close after a delay of 500 milliseconds.|(((
720 720  OK
721 721  
722 722  
723 723  )))
724 724  
737 +
725 725  **Downlink Command: 0x07**
726 726  
727 727  Format: Command Code (0x07) followed by 3 bytes.
... ... @@ -735,24 +735,27 @@
735 735  * Example 5: Downlink Payload: 070301F4  -> AT+12VT=500
736 736  * Example 6: Downlink Payload: 07030000  -> AT+12VT=0
737 737  
738 -1.
739 -11. Set the Probe Model
740 740  
752 +
753 +== 3.4 Set the Probe Model ==
754 +
755 +
741 741  **AT Command: AT** **+PROBE**
742 742  
743 -|**Command Example**|**Function**|**Response**
744 -|AT +PROBE =?|Get or Set the probe model.|(((
758 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
759 +|(% style="width:157px" %)**Command Example**|(% style="width:267px" %)**Function**|**Response**
760 +|(% style="width:157px" %)AT +PROBE =?|(% style="width:267px" %)Get or Set the probe model.|(((
745 745  0
746 746  
747 747  OK
748 748  )))
749 -|AT +PROBE =0003|Set water depth sensor mode, 3m type.|OK
750 -|AT +PROBE =0101|Set pressure transmitters mode, first type.|(((
765 +|(% style="width:157px" %)AT +PROBE =0003|(% style="width:267px" %)Set water depth sensor mode, 3m type.|OK
766 +|(% style="width:157px" %)AT +PROBE =0101|(% style="width:267px" %)Set pressure transmitters mode, first type.|(((
751 751  OK
752 752  
753 753  
754 754  )))
755 -|AT +PROBE =0000|Initial state, no settings.|(((
771 +|(% style="width:157px" %)AT +PROBE =0000|(% style="width:267px" %)Initial state, no settings.|(((
756 756  OK
757 757  
758 758  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved