... ... @@ -197,7 +197,7 @@
197 197  [[image:1675071855856-879.png]]
198 198  
199 199  
200 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
200 +(% border="1" cellspacing="4" style="background-color:#ffffcc; color:black; width:510px" %)
201 201  |(% style="width:138px" %)**Behavior on ACT**|(% style="width:100px" %)**Function**|**Action**
202 202  |(% style="width:138px" %)Pressing ACT between 1s < time < 3s|(% style="width:100px" %)Send an uplink|(((
203 203  If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, **blue led** will blink once.
... ... @@ -313,9 +313,12 @@
313 313  
314 314  
315 315  
316 -== 2.3 ​Uplink Payload ==
317 317  
318 318  
318 +
319 +1.
320 +11. ​Uplink Payload
321 +
319 319  Uplink payloads have two types:
320 320  
321 321  * Distance Value: Use FPORT=2
... ... @@ -324,24 +324,27 @@
324 324  The application server should parse the correct value based on FPORT settings.
325 325  
326 326  
327 -=== 2.3.1 Device Status, FPORT~=5 ===
328 328  
331 +1.
332 +11.
333 +111. Device Status, FPORT=5
329 329  
330 330  Include device configure status. Once PS-LB Joined the network, it will uplink this message to the server.
331 331  
337 +
332 332  Users can also use the downlink command(0x26 01) to ask PS-LB to resend this uplink.
333 333  
334 334  
335 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
336 336  |(% colspan="6" %)**Device Status (FPORT=5)**
337 -|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|**1**|**1**|**2**
338 -|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|Frequency Band|Sub-band|BAT
342 +|**Size (bytes)**|**1**|**2**|**1**|**1**|**2**
343 +|**Value**|Sensor Model|Firmware Version|Frequency Band|Sub-band|BAT
339 339  
340 340  Example parse in TTNv3
341 341  
342 -[[image:1675144504430-490.png]]
347 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image021.png]]
343 343  
344 344  
350 +
345 345  **Sensor Model**: For PS-LB, this value is 0x16
346 346  
347 347  **Firmware Version**: 0x0100, Means: v1.0.0 version
... ... @@ -395,13 +395,14 @@
395 395  Ex2: 0x0B49 = 2889mV
396 396  
397 397  
398 -=== 1.3.2 Sensor value, FPORT~=2 ===
399 399  
405 +1.
406 +11.
407 +111. Sensor value, FPORT=2
400 400  
401 401  Uplink payload includes in total 9 bytes.
402 402  
403 403  
404 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
405 405  |(((
406 406  **Size**
407 407  
1675144608950-310.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -31.5 KB
Content
1675144839454-913.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -59.2 KB
Content
1675144951092-237.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -62.2 KB