From version < 16.3 >
edited by Xiaoling
on 2023/01/31 12:00
To version < 16.1 >
edited by Xiaoling
on 2023/01/31 11:52
>
Change comment: Uploaded new attachment "image-20230131115217-1.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -1,10 +1,12 @@
1 -[[image:image-20230131115217-1.png]]
1 +[[image:image-20230130161957-1.jpeg||height="493" width="493"]] [[image:image-20230130162222-3.png||height="495" width="477"]]
2 2  
3 3  
4 4  
5 +
5 5  **Table of Contents:**
6 6  
7 7  
9 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image002.png]]
8 8  
9 9  
10 10  
... ... @@ -18,8 +18,9 @@
18 18  
19 19  
20 20  
21 -= 1. Introduction =
22 22  
24 += 1. Introduction =
25 +
23 23  == 1.1 What is LoRaWAN Pressure Sensor ==
24 24  
25 25  
... ... @@ -56,6 +56,7 @@
56 56  * 8500mAh Battery for long term use
57 57  
58 58  
62 +
59 59  == 1.3 Specification ==
60 60  
61 61  
... ... @@ -103,11 +103,14 @@
103 103  * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
104 104  
105 105  
110 +
106 106  == 1.4 Probe Types ==
107 107  
113 +
108 108  === 1.4.1 Thread Installation Type ===
109 109  
110 110  
117 +
111 111  [[image:1675071448299-229.png]]
112 112  
113 113  * Hersman Pressure Transmitter
... ... @@ -122,9 +122,11 @@
122 122  * Connector Type: Various Types, see order info
123 123  
124 124  
132 +
125 125  === 1.4.2 Immersion Type ===
126 126  
127 127  
136 +
128 128  [[image:1675071521308-426.png]]
129 129  
130 130  * Immersion Type, Probe IP Level: IP68
... ... @@ -139,6 +139,7 @@
139 139  * Material: 316 stainless steels
140 140  
141 141  
151 +
142 142  == 1.5 Probe Dimension ==
143 143  
144 144  
... ... @@ -159,6 +159,7 @@
159 159  * Constant Pressure Water Supply
160 160  * Liquid Pressure measuring
161 161  
172 +
162 162  Order the suitable thread size and install to measure the air / liquid pressure
163 163  
164 164  [[image:1675071670469-145.png]]
... ... @@ -197,14 +197,13 @@
197 197  [[image:1675071855856-879.png]]
198 198  
199 199  
200 -(% border="1" cellspacing="4" style="background-color:#ffffcc; color:black; width:510px" %)
201 -|(% style="width:138px" %)**Behavior on ACT**|(% style="width:100px" %)**Function**|**Action**
202 -|(% style="width:138px" %)Pressing ACT between 1s < time < 3s|(% style="width:100px" %)Send an uplink|(((
211 +|**Behavior on ACT**|**Function**|**Action**
212 +|Pressing ACT between 1s < time < 3s|Send an uplink|(((
203 203  If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, **blue led** will blink once.
204 204  
205 205  Meanwhile, BLE module will be active and user can connect via BLE to configure device.
206 206  )))
207 -|(% style="width:138px" %)Pressing ACT for more than 3s|(% style="width:100px" %)Active Device|(((
217 +|Pressing ACT for more than 3s|Active Device|(((
208 208  **Green led** will fast blink 5 times, device will enter **OTA mode** for 3 seconds. And then start to JOIN LoRaWAN network.
209 209  
210 210  **Green led** will solidly turn on for 5 seconds after joined in network.
... ... @@ -211,10 +211,9 @@
211 211  
212 212  Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network.
213 213  )))
214 -|(% style="width:138px" %)Fast press ACT 5 times.|(% style="width:100px" %)Deactivate Device|red led will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.
224 +|Fast press ACT 5 times.|Deactivate Device|red led will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.
215 215  
216 216  
217 -
218 218  == 1.9 Pin Mapping ==
219 219  
220 220  
... ... @@ -221,8 +221,9 @@
221 221  [[image:1675072568006-274.png]]
222 222  
223 223  
224 -== 1.10 BLE connection ==
225 225  
234 +1.
235 +11. BLE connection
226 226  
227 227  PS-LB support BLE remote configure.
228 228  
... ... @@ -238,7 +238,7 @@
238 238  
239 239  
240 240  
241 -1.
251 +1.
242 242  11. Mechanical
243 243  
244 244  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image012.png]]
... ... @@ -256,7 +256,7 @@
256 256  The PS-LB is configured as **LoRaWAN OTAA Class A** mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and activate the PS-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
257 257  
258 258  
259 -1.
269 +1.
260 260  11. ​Quick guide to connect to LoRaWAN server (OTAA)
261 261  
262 262  Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example.
... ... @@ -333,8 +333,8 @@
333 333  
334 334  
335 335  
336 -1.
337 -11.
346 +1.
347 +11.
338 338  111. Device Status, FPORT=5
339 339  
340 340  Include device configure status. Once PS-LB Joined the network, it will uplink this message to the server.
... ... @@ -407,10 +407,11 @@
407 407  
408 408  
409 409  
410 -1.
411 -11.
420 +1.
421 +11.
412 412  111. Sensor value, FPORT=2
413 413  
424 +
414 414  Uplink payload includes in total 9 bytes.
415 415  
416 416  
... ... @@ -425,12 +425,13 @@
425 425  
426 426  
427 427  
439 +
428 428  [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image020.png]]
429 429  
430 430  
431 431  
432 432  1.
433 -11.
445 +11.
434 434  111. Battery Info
435 435  
436 436  Check the battery voltage for PS-LB.
... ... @@ -440,8 +440,8 @@
440 440  Ex2: 0x0B49 = 2889mV
441 441  
442 442  
443 -1.
444 -11.
455 +1.
456 +11.
445 445  111. Probe Model
446 446  
447 447  PS-LB has different kind of probe, 0~~20mA represent the full scale of the measuring range. So a 15mA output means different meaning for different probe. 
... ... @@ -456,8 +456,8 @@
456 456  The probe model field provides the convenient for server to identical how it should parse the 0~~20mA sensor value and get the correct value.
457 457  
458 458  
459 -1.
460 -11.
471 +1.
472 +11.
461 461  111. 0~~20mA value (IDC_IN)
462 462  
463 463  The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level.
... ... @@ -468,8 +468,8 @@
468 468  27AE(H) = 10158 (D)/1000 = 10.158mA.
469 469  
470 470  
471 -1.
472 -11.
483 +1.
484 +11.
473 473  111. 0~~30V value ( pin VDC_IN)
474 474  
475 475  Measure the voltage value. The range is 0 to 30V.
... ... @@ -480,10 +480,11 @@
480 480  138E(H) = 5006(D)/1000= 5.006V
481 481  
482 482  
483 -1.
484 -11.
495 +1.
496 +11.
485 485  111. IN1&IN2&INT pin
486 486  
499 +
487 487  IN1 and IN2 are used as digital input pins.
488 488  
489 489  **Example**:
... ... @@ -511,8 +511,8 @@
511 511  
512 512  
513 513  
514 -1.
515 -11.
527 +1.
528 +11.
516 516  111. ​Decode payload in The Things Network
517 517  
518 518  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -525,7 +525,7 @@
525 525  [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]]
526 526  
527 527  
528 -1.
541 +1.
529 529  11. Uplink Interval
530 530  
531 531  The PS-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:
... ... @@ -534,7 +534,7 @@
534 534  
535 535  
536 536  
537 -1.
550 +1.
538 538  11. ​Show Data in DataCake IoT Server
539 539  
540 540  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
... ... @@ -606,7 +606,7 @@
606 606  
607 607  
608 608  
609 -1.
622 +1.
610 610  11. ​Firmware Change Log
611 611  
612 612  **Firmware download link:**
... ... @@ -644,7 +644,7 @@
644 644  These commands only valid for PS-LB, as below:
645 645  
646 646  
647 -1.
660 +1.
648 648  11. Set Transmit Interval Time
649 649  
650 650  Feature: Change LoRaWAN End Node Transmit Interval.
... ... @@ -675,7 +675,8 @@
675 675  * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
676 676  
677 677  
678 -1.
691 +
692 +1.
679 679  11. Set Interrupt Mode
680 680  
681 681  Feature, Set Interrupt mode for GPIO_EXIT.
... ... @@ -708,7 +708,7 @@
708 708  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
709 709  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
710 710  
711 -1.
725 +1.
712 712  11. Set the output time
713 713  
714 714  Feature, Control the output 3V3 , 5V or 12V.
... ... @@ -789,7 +789,7 @@
789 789  * Example 5: Downlink Payload: 070301F4  -> AT+12VT=500
790 790  * Example 6: Downlink Payload: 07030000  -> AT+12VT=0
791 791  
792 -1.
806 +1.
793 793  11. Set the Probe Model
794 794  
795 795  **AT Command: AT** **+PROBE**
... ... @@ -821,6 +821,7 @@
821 821  
822 822  
823 823  
838 +
824 824  1. Battery & how to replace
825 825  11. Battery Type
826 826  
... ... @@ -837,7 +837,7 @@
837 837  PS-LB:  2.45v ~~ 3.6v
838 838  
839 839  
840 -1.
855 +1.
841 841  11. Replace Battery
842 842  
843 843  Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
... ... @@ -846,7 +846,7 @@
846 846  
847 847  
848 848  
849 -1.
864 +1.
850 850  11. Power Consumption Analyze
851 851  
852 852  Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
... ... @@ -877,6 +877,7 @@
877 877  * [[Lithium-Thionyl Chloride Battery>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/ER18505_datasheet-EN.pdf]] datasheet, [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/ER18505_datasheet_PM-ER18505-S-02-LF_EN.pdf]]
878 878  * [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
879 879  
895 +
880 880  |(((
881 881  JST-XH-2P connector
882 882  )))
... ... @@ -886,14 +886,14 @@
886 886  
887 887  
888 888  1.
889 -11.
905 +11.
890 890  111. ​Battery Note
891 891  
892 892  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
893 893  
894 894  
895 -1.
896 -11.
911 +1.
912 +11.
897 897  111. ​Replace the battery
898 898  
899 899  You can change the battery in the PS-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
... ... @@ -914,9 +914,10 @@
914 914  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]
915 915  
916 916  
917 -1.
933 +1.
918 918  11. AT Command Set
919 919  
936 +
920 920  1. OTA firmware update
921 921  
922 922  Please see this link for how to do OTA firmware update.
... ... @@ -933,7 +933,7 @@
933 933  See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]
934 934  
935 935  
936 -1.
953 +1.
937 937  11. How to update firmware via UART port?
938 938  
939 939  See:
... ... @@ -941,7 +941,7 @@
941 941  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]
942 942  
943 943  
944 -1.
961 +1.
945 945  11. How to change the LoRa Frequency Bands/Region
946 946  
947 947  You can follow the instructions for [[how to upgrade image>>path:#3ygebqi]].
... ... @@ -974,6 +974,7 @@
974 974  
975 975  
976 976  
994 +
977 977  1. ​Support
978 978  
979 979  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0