Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/07/10 16:21
From version 146.1
edited by Xiaoling
on 2025/06/10 15:28
on 2025/06/10 15:28
Change comment:
There is no comment for this version
To version 140.1
edited by Mengting Qiu
on 2025/06/03 17:14
on 2025/06/03 17:14
Change comment:
Uploaded new attachment "image-20250603171424-1.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.ting - Content
-
... ... @@ -1,7 +1,8 @@ 1 1 2 2 3 3 4 -[[image:image-20240109154731-4.png||data-xwiki-image-style-alignment="center" height="546" width="769"]] 4 +(% style="text-align:center" %) 5 +[[image:image-20240109154731-4.png||height="546" width="769"]] 5 5 6 6 7 7 ... ... @@ -245,16 +245,20 @@ 245 245 246 246 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 247 247 |=(% style="width: 167px;background-color:#4F81BD;color:white" %)Behavior on ACT|=(% style="width: 117px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 226px;background-color:#4F81BD;color:white" %)Action 248 -|[[image:1749540420016-961.png]] 1~~3s|(% style="background-color:#f2f2f2; width:117px" %)Send an uplink|(% style="background-color:#f2f2f2; width:225px" %)((( 249 +|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2; width:117px" %)Send an uplink|(% style="background-color:#f2f2f2; width:225px" %)((( 250 + 251 + 249 249 If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, blue led will blink once. 250 250 Meanwhile, BLE module will be active and user can connect via BLE to configure device. 251 251 ))) 252 -|[[image:1749540423574-437.png]] >3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)((( 255 +|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT for more than 3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)((( 256 + 257 + 253 253 Green led will fast blink 5 times, device will enter OTA mode for 3 seconds. And then start to JOIN LoRaWAN network. 254 254 Green led will solidly turn on for 5 seconds after joined in network. 255 255 Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network. 256 256 ))) 257 -| [[image:1749540397649-875.png]]x5|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)Red led will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.262 +|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)Red led will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 258 258 259 259 == 1.8 Pin Mapping == 260 260 ... ... @@ -1435,30 +1435,6 @@ 1435 1435 [[image:image-20240329175044-1.png]] 1436 1436 1437 1437 1438 -== 6.5 Cable & Probe Material Compatibility(Immersion type) == 1439 - 1440 - 1441 -Since the installation method of immersion sensors requires immersion in a liquid environment, the discussion of liquids that can be safely installed is very important. 1442 - 1443 -(% style="color:blue" %)**The material of the immersed part of the immersion sensor:** 1444 - 1445 -* **Cable Jacket**: Black polyurethane (PU) – Resistant to water, oils, and mild chemicals. 1446 -* **Probe Material**: 316 stainless steel – Corrosion-resistant in most industrial/marine environments. 1447 - 1448 -(% style="color:blue" %)**Chemical Compatibility:** 1449 - 1450 -* **Polyurethane (PU) Cable:** Resists water, oils, fuels, and mild chemicals but may degrade with prolonged exposure to strong acids, bases, or solvents (e.g., acetone, chlorinated hydrocarbons). 1451 -* 3**16 Stainless Steel Probe:** Suitable for water, seawater, mild acids/alkalis, and industrial fluids. Avoid highly concentrated acids (e.g., hydrochloric acid) or chlorides at high temperatures. 1452 - 1453 -**Chemical Resistance Chart for Polyurethane (PU) Cable** 1454 - 1455 -[[image:image-20250603171424-1.png||height="429" width="625"]] 1456 - 1457 -**Chemical Resistance Chart for 316 Stainless Steel Probe** 1458 - 1459 -[[image:image-20250603171503-2.png||height="350" width="616"]] 1460 - 1461 - 1462 1462 = 7. Troubleshooting = 1463 1463 1464 1464 == 7.1 Water Depth Always shows 0 in payload ==
- 1749540397649-875.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.4 KB - Content
- 1749540420016-961.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.9 KB - Content
- 1749540423574-437.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.9 KB - Content
- image-20250603171503-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -33.7 KB - Content