Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/07/10 16:21
From version 141.1
edited by Mengting Qiu
on 2025/06/03 17:15
on 2025/06/03 17:15
Change comment:
Uploaded new attachment "image-20250603171503-2.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Xiaoling - Content
-
... ... @@ -1,8 +1,7 @@ 1 1 2 2 3 3 4 -(% style="text-align:center" %) 5 -[[image:image-20240109154731-4.png||height="546" width="769"]] 4 +[[image:image-20240109154731-4.png||data-xwiki-image-style-alignment="center" height="546" width="769"]] 6 6 7 7 8 8 ... ... @@ -246,13 +246,13 @@ 246 246 247 247 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 248 248 |=(% style="width: 167px;background-color:#4F81BD;color:white" %)Behavior on ACT|=(% style="width: 117px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 226px;background-color:#4F81BD;color:white" %)Action 249 -| (% style="background-color:#f2f2f2; width:167px" %)PressingACT between1s < time <3s|(% style="background-color:#f2f2f2; width:117px" %)Send an uplink|(% style="background-color:#f2f2f2; width:225px" %)(((248 +|[[image:1749521239729-288.png]] 1~~3s|(% style="background-color:#f2f2f2; width:117px" %)Send an uplink|(% style="background-color:#f2f2f2; width:225px" %)((( 250 250 251 251 252 252 If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, blue led will blink once. 253 253 Meanwhile, BLE module will be active and user can connect via BLE to configure device. 254 254 ))) 255 -| (% style="background-color:#f2f2f2; width:167px" %)PressingACT for more than3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)(((254 +|[[image:1749521245437-170.png]] >3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)((( 256 256 257 257 258 258 Green led will fast blink 5 times, device will enter OTA mode for 3 seconds. And then start to JOIN LoRaWAN network. ... ... @@ -259,7 +259,7 @@ 259 259 Green led will solidly turn on for 5 seconds after joined in network. 260 260 Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network. 261 261 ))) 262 -| (% style="background-color:#f2f2f2; width:167px"%)Fast press ACT5times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)Red led will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.261 +|[[image:1749521282079-419.png]] x5|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)Red led will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 263 263 264 264 == 1.8 Pin Mapping == 265 265 ... ... @@ -1440,6 +1440,30 @@ 1440 1440 [[image:image-20240329175044-1.png]] 1441 1441 1442 1442 1442 +== 6.5 Cable & Probe Material Compatibility(Immersion type) == 1443 + 1444 + 1445 +Since the installation method of immersion sensors requires immersion in a liquid environment, the discussion of liquids that can be safely installed is very important. 1446 + 1447 +(% style="color:blue" %)**The material of the immersed part of the immersion sensor:** 1448 + 1449 +* **Cable Jacket**: Black polyurethane (PU) – Resistant to water, oils, and mild chemicals. 1450 +* **Probe Material**: 316 stainless steel – Corrosion-resistant in most industrial/marine environments. 1451 + 1452 +(% style="color:blue" %)**Chemical Compatibility:** 1453 + 1454 +* **Polyurethane (PU) Cable:** Resists water, oils, fuels, and mild chemicals but may degrade with prolonged exposure to strong acids, bases, or solvents (e.g., acetone, chlorinated hydrocarbons). 1455 +* 3**16 Stainless Steel Probe:** Suitable for water, seawater, mild acids/alkalis, and industrial fluids. Avoid highly concentrated acids (e.g., hydrochloric acid) or chlorides at high temperatures. 1456 + 1457 +**Chemical Resistance Chart for Polyurethane (PU) Cable** 1458 + 1459 +[[image:image-20250603171424-1.png||height="429" width="625"]] 1460 + 1461 +**Chemical Resistance Chart for 316 Stainless Steel Probe** 1462 + 1463 +[[image:image-20250603171503-2.png||height="350" width="616"]] 1464 + 1465 + 1443 1443 = 7. Troubleshooting = 1444 1444 1445 1445 == 7.1 Water Depth Always shows 0 in payload ==
- 1749540397649-875.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.4 KB - Content