Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/07/10 16:21
From version 138.1
edited by Mengting Qiu
on 2025/05/23 08:45
on 2025/05/23 08:45
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Xiaoling - Content
-
... ... @@ -1,8 +1,7 @@ 1 1 2 2 3 3 4 -(% style="text-align:center" %) 5 -[[image:image-20240109154731-4.png||height="546" width="769"]] 4 +[[image:image-20240109154731-4.png||data-xwiki-image-style-alignment="center" height="546" width="769"]] 6 6 7 7 8 8 ... ... @@ -142,7 +142,11 @@ 142 142 * Long-Term Stability: ±0.2% F.S / Year 143 143 * Storage temperature: -30°C~~80°C 144 144 * Operating temperature: 0°C~~50°C 145 -* Material: 316 stainless steels 144 +* Probe Material: 316 stainless steels 145 +* Cable model specifications: CGYPU 5*0.2mm2 146 +* Usage characteristics of Cable 147 +1) Operating temperature:-40℃— +70℃ 148 +2) -30℃ bending cable 15 times of outer diameter can work normally 146 146 147 147 === 1.4.3 Wireless Differential Air Pressure Sensor === 148 148 ... ... @@ -242,13 +242,13 @@ 242 242 243 243 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 244 244 |=(% style="width: 167px;background-color:#4F81BD;color:white" %)Behavior on ACT|=(% style="width: 117px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 226px;background-color:#4F81BD;color:white" %)Action 245 -| (% style="background-color:#f2f2f2; width:167px" %)PressingACT between1s < time <3s|(% style="background-color:#f2f2f2; width:117px" %)Send an uplink|(% style="background-color:#f2f2f2; width:225px" %)(((248 +|[[image:1749521239729-288.png]] 1~~3s|(% style="background-color:#f2f2f2; width:117px" %)Send an uplink|(% style="background-color:#f2f2f2; width:225px" %)((( 246 246 247 247 248 248 If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, blue led will blink once. 249 249 Meanwhile, BLE module will be active and user can connect via BLE to configure device. 250 250 ))) 251 -| (% style="background-color:#f2f2f2; width:167px" %)PressingACT for more than3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)(((254 +|[[image:1749521245437-170.png]] >3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)((( 252 252 253 253 254 254 Green led will fast blink 5 times, device will enter OTA mode for 3 seconds. And then start to JOIN LoRaWAN network. ... ... @@ -255,7 +255,7 @@ 255 255 Green led will solidly turn on for 5 seconds after joined in network. 256 256 Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network. 257 257 ))) 258 -| (% style="background-color:#f2f2f2; width:167px"%)Fast press ACT5times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)Red led will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.261 +|[[image:1749521282079-419.png]] x5|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)Red led will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 259 259 260 260 == 1.8 Pin Mapping == 261 261 ... ... @@ -1265,7 +1265,6 @@ 1265 1265 1266 1266 * Example 1: Downlink Payload: AE 01 02 58 12 ~-~--> AT+STDC=1,600,18 1267 1267 1268 - 1269 1269 == 3.4 Print data entries base on page(Since v1.1.0) == 1270 1270 1271 1271 ... ... @@ -1437,6 +1437,30 @@ 1437 1437 [[image:image-20240329175044-1.png]] 1438 1438 1439 1439 1442 +== 6.5 Cable & Probe Material Compatibility(Immersion type) == 1443 + 1444 + 1445 +Since the installation method of immersion sensors requires immersion in a liquid environment, the discussion of liquids that can be safely installed is very important. 1446 + 1447 +(% style="color:blue" %)**The material of the immersed part of the immersion sensor:** 1448 + 1449 +* **Cable Jacket**: Black polyurethane (PU) – Resistant to water, oils, and mild chemicals. 1450 +* **Probe Material**: 316 stainless steel – Corrosion-resistant in most industrial/marine environments. 1451 + 1452 +(% style="color:blue" %)**Chemical Compatibility:** 1453 + 1454 +* **Polyurethane (PU) Cable:** Resists water, oils, fuels, and mild chemicals but may degrade with prolonged exposure to strong acids, bases, or solvents (e.g., acetone, chlorinated hydrocarbons). 1455 +* 3**16 Stainless Steel Probe:** Suitable for water, seawater, mild acids/alkalis, and industrial fluids. Avoid highly concentrated acids (e.g., hydrochloric acid) or chlorides at high temperatures. 1456 + 1457 +**Chemical Resistance Chart for Polyurethane (PU) Cable** 1458 + 1459 +[[image:image-20250603171424-1.png||height="429" width="625"]] 1460 + 1461 +**Chemical Resistance Chart for 316 Stainless Steel Probe** 1462 + 1463 +[[image:image-20250603171503-2.png||height="350" width="616"]] 1464 + 1465 + 1440 1440 = 7. Troubleshooting = 1441 1441 1442 1442 == 7.1 Water Depth Always shows 0 in payload ==
- image-20250603171424-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.7 KB - Content
- image-20250603171503-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +33.7 KB - Content