<
From version < 123.9 >
edited by Xiaoling
on 2025/04/01 17:02
To version < 123.12 >
edited by Xiaoling
on 2025/04/01 17:08
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -679,7 +679,6 @@
679 679  )))|(% style="width:86px" %)Unix Time Stamp
680 680  
681 681  
682 -
683 683  IN1_pin_level & IN2_pin_level & Exti_pin_level & Exti_status:
684 684  
685 685  [[image:image-20250117104847-4.png]]
... ... @@ -853,6 +853,7 @@
853 853  
854 854  ==== 2.8.2.1 Wave alarm mode ====
855 855  
855 +
856 856  Feature: By setting the detection period and a change value, the IDC/VDC variable is monitored whether it exceeds the set change value. If this change value is exceeded, the ROC uplink is sent and the comparison value is flushed.
857 857  
858 858  * Change value: The amount by which the next detection value increases/decreases relative to the previous detection value.
... ... @@ -869,22 +869,21 @@
869 869  |(% colspan="1" rowspan="4" style="width:143px" %)(((
870 870  AT+ROC=a,b,c,d
871 871  )))|(% style="width:154px" %)(((
872 -a: Enable or disable the ROC
872 +**a:** Enable or disable the ROC
873 873  )))|(% style="width:197px" %)(((
874 -0: off
875 -1: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value.
876 -
877 -2: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]).
874 +**0:** off
875 +**1:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value.
876 +**2:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]).
878 878  )))
879 -|(% style="width:154px" %)b: Set the detection interval|(% style="width:197px" %)(((
878 +|(% style="width:154px" %)**b:** Set the detection interval|(% style="width:197px" %)(((
880 880  Range:  0~~65535s
881 881  )))
882 -|(% style="width:154px" %)c: Setting the IDC change value|(% style="width:197px" %)Unit: uA
883 -|(% style="width:154px" %)d: Setting the VDC change value|(% style="width:197px" %)Unit: mV
881 +|(% style="width:154px" %)**c:** Setting the IDC change value|(% style="width:197px" %)Unit: uA
882 +|(% style="width:154px" %)**d:** Setting the VDC change value|(% style="width:197px" %)Unit: mV
884 884  
885 885  Example:
886 886  
887 -* AT+ROC=0,0,0,0  ~/~/The ROC function is not used.
886 +* AT+ROC=0,0,0,0  ~/~/ The ROC function is not used.
888 888  * AT+ROC=1,60,3000, 500  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink, and the comparison value is refreshed.
889 889  * AT+ROC=1,60,3000,0  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage.
890 890  * AT+ROC=2,60,3000,0  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. In addition, if the change in the IDC does not exceed 3mA, then the ROC uplink is not sent, and the comparison value is not refreshed by the ROC uplink packet. However, if the device TDC time arrives, or if the user manually sends packets, then the IDC comparison value is also refreshed.
... ... @@ -903,9 +903,9 @@
903 903  
904 904  Example:
905 905  
906 -* Downlink Payload: 09 01 00 3C 0B B8 01 F4  ~/~/Equal to AT+ROC=1,60,3000, 500
907 -* Downlink Payload: 09 01 00 3C 0B B8 00 00  ~/~/Equal to AT+ROC=1,60,3000,0
908 -* Downlink Payload: 09 02 00 3C 0B B8 00 00  ~/~/Equal to AT+ROC=2,60,3000,0
905 +* Downlink Payload: 09 01 00 3C 0B B8 01 F4  ~/~/ Equal to AT+ROC=1,60,3000, 500
906 +* Downlink Payload: 09 01 00 3C 0B B8 00 00  ~/~/ Equal to AT+ROC=1,60,3000,0
907 +* Downlink Payload: 09 02 00 3C 0B B8 00 00  ~/~/ Equal to AT+ROC=2,60,3000,0
909 909  
910 910  Screenshot of parsing example in TTN:
911 911  
... ... @@ -916,6 +916,7 @@
916 916  
917 917  ==== 2.8.2.2 Over-threshold alarm mode ====
918 918  
918 +
919 919  Feature: Monitors whether the IDC/VDC exceeds the threshold by setting the detection period and threshold. Alarm if the threshold is exceeded.
920 920  
921 921  AT Command: AT+ROC=3,a,b,c,d,e
... ... @@ -923,57 +923,36 @@
923 923  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
924 924  |=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 160px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 185px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation
925 925  |(% style="width:143px" %)AT+ROC=?|(% style="width:160px" %)Show current ROC setting|(% style="width:185px" %)(((
926 -
927 -
928 928  0,0,0,0(default)
929 929  OK
930 930  )))
931 931  |(% colspan="1" rowspan="5" style="width:143px" %)(((
932 -
933 -
934 -
935 -
936 -
937 937  AT+ROC=3,a,b,c,d,e
938 938  )))|(% style="width:160px" %)(((
939 -
940 -
941 -a: Set the detection interval
932 +**a:** Set the detection interval
942 942  )))|(% style="width:185px" %)(((
943 -
944 -
945 945  Range:  0~~65535s
946 946  )))
947 -|(% style="width:160px" %)b: Set the IDC alarm trigger condition|(% style="width:185px" %)(((
948 -
949 -
950 -0: Less than the set IDC threshold, Alarm
951 -
952 -1: Greater than the set IDC threshold, Alarm
936 +|(% style="width:160px" %)**b:** Set the IDC alarm trigger condition|(% style="width:185px" %)(((
937 +**0:** Less than the set IDC threshold, Alarm
938 +**1:** Greater than the set IDC threshold, Alarm
953 953  )))
954 954  |(% style="width:160px" %)(((
955 -
956 -
957 -c:  IDC alarm threshold
941 +**c: ** IDC alarm threshold
958 958  )))|(% style="width:185px" %)(((
959 -
960 -
961 961  Unit: uA
962 962  )))
963 -|(% style="width:160px" %)d: Set the VDC alarm trigger condition|(% style="width:185px" %)(((
964 -
965 -
966 -0: Less than the set VDC threshold, Alarm
967 -
968 -1: Greater than the set VDC threshold, Alarm
945 +|(% style="width:160px" %)**d:** Set the VDC alarm trigger condition|(% style="width:185px" %)(((
946 +**0:** Less than the set VDC threshold, Alarm
947 +**1:** Greater than the set VDC threshold, Alarm
969 969  )))
970 -|(% style="width:160px" %)e: VDC alarm threshold|(% style="width:185px" %)Unit: mV
949 +|(% style="width:160px" %)**e:** VDC alarm threshold|(% style="width:185px" %)Unit: mV
971 971  
972 972  Example:
973 973  
974 -* AT+ROC=3,60,0,3000,0,5000  ~/~/The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated.
975 -* AT+ROC=3,180,1,3000,1,5000  ~/~/The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated.
976 -* AT+ROC=3,300,0,3000,1,5000  ~/~/The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated.
953 +* AT+ROC=3,60,0,3000,0,5000  ~/~/ The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated.
954 +* AT+ROC=3,180,1,3000,1,5000  ~/~/ The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated.
955 +* AT+ROC=3,300,0,3000,1,5000  ~/~/ The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated.
977 977  
978 978  Downlink Command: 0x09 03 aa bb cc dd ee
979 979  
... ... @@ -992,9 +992,9 @@
992 992  
993 993  Example:
994 994  
995 -* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,0,5000
996 -* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38  ~/~/Equal to AT+ROC=3,60,1,3000,1,5000
997 -* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38  ~/~/Equal to AT+ROC=3,60,0,3000,1,5000
974 +* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/ Equal to AT+ROC=3,60,0,3000,0,5000
975 +* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38  ~/~/ Equal to AT+ROC=3,60,1,3000,1,5000
976 +* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38  ~/~/ Equal to AT+ROC=3,60,0,3000,1,5000
998 998  
999 999  Screenshot of parsing example in TTN:
1000 1000  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0