Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/27 10:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -679,7 +679,6 @@ 679 679 )))|(% style="width:86px" %)Unix Time Stamp 680 680 681 681 682 - 683 683 IN1_pin_level & IN2_pin_level & Exti_pin_level & Exti_status: 684 684 685 685 [[image:image-20250117104847-4.png]] ... ... @@ -853,6 +853,7 @@ 853 853 854 854 ==== 2.8.2.1 Wave alarm mode ==== 855 855 855 + 856 856 Feature: By setting the detection period and a change value, the IDC/VDC variable is monitored whether it exceeds the set change value. If this change value is exceeded, the ROC uplink is sent and the comparison value is flushed. 857 857 858 858 * Change value: The amount by which the next detection value increases/decreases relative to the previous detection value. ... ... @@ -869,22 +869,21 @@ 869 869 |(% colspan="1" rowspan="4" style="width:143px" %)((( 870 870 AT+ROC=a,b,c,d 871 871 )))|(% style="width:154px" %)((( 872 -a: Enable or disable the ROC 872 +**a:** Enable or disable the ROC 873 873 )))|(% style="width:197px" %)((( 874 -0: off 875 -1: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 876 - 877 -2: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]). 874 +**0:** off 875 +**1:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 876 +**2:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]). 878 878 ))) 879 -|(% style="width:154px" %)b: Set the detection interval|(% style="width:197px" %)((( 878 +|(% style="width:154px" %)**b:** Set the detection interval|(% style="width:197px" %)((( 880 880 Range: 0~~65535s 881 881 ))) 882 -|(% style="width:154px" %)c: Setting the IDC change value|(% style="width:197px" %)Unit: uA 883 -|(% style="width:154px" %)d: Setting the VDC change value|(% style="width:197px" %)Unit: mV 881 +|(% style="width:154px" %)**c:** Setting the IDC change value|(% style="width:197px" %)Unit: uA 882 +|(% style="width:154px" %)**d:** Setting the VDC change value|(% style="width:197px" %)Unit: mV 884 884 885 885 Example: 886 886 887 -* AT+ROC=0,0,0,0 ~/~/The ROC function is not used. 886 +* AT+ROC=0,0,0,0 ~/~/ The ROC function is not used. 888 888 * AT+ROC=1,60,3000, 500 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink, and the comparison value is refreshed. 889 889 * AT+ROC=1,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. 890 890 * AT+ROC=2,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. In addition, if the change in the IDC does not exceed 3mA, then the ROC uplink is not sent, and the comparison value is not refreshed by the ROC uplink packet. However, if the device TDC time arrives, or if the user manually sends packets, then the IDC comparison value is also refreshed. ... ... @@ -903,9 +903,9 @@ 903 903 904 904 Example: 905 905 906 -* Downlink Payload: 09 01 00 3C 0B B8 01 F4 ~/~/Equal to AT+ROC=1,60,3000, 500 907 -* Downlink Payload: 09 01 00 3C 0B B8 00 00 ~/~/Equal to AT+ROC=1,60,3000,0 908 -* Downlink Payload: 09 02 00 3C 0B B8 00 00 ~/~/Equal to AT+ROC=2,60,3000,0 905 +* Downlink Payload: 09 01 00 3C 0B B8 01 F4 ~/~/ Equal to AT+ROC=1,60,3000, 500 906 +* Downlink Payload: 09 01 00 3C 0B B8 00 00 ~/~/ Equal to AT+ROC=1,60,3000,0 907 +* Downlink Payload: 09 02 00 3C 0B B8 00 00 ~/~/ Equal to AT+ROC=2,60,3000,0 909 909 910 910 Screenshot of parsing example in TTN: 911 911 ... ... @@ -916,6 +916,7 @@ 916 916 917 917 ==== 2.8.2.2 Over-threshold alarm mode ==== 918 918 918 + 919 919 Feature: Monitors whether the IDC/VDC exceeds the threshold by setting the detection period and threshold. Alarm if the threshold is exceeded. 920 920 921 921 AT Command: AT+ROC=3,a,b,c,d,e ... ... @@ -923,57 +923,36 @@ 923 923 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 924 924 |=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 160px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 185px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation 925 925 |(% style="width:143px" %)AT+ROC=?|(% style="width:160px" %)Show current ROC setting|(% style="width:185px" %)((( 926 - 927 - 928 928 0,0,0,0(default) 929 929 OK 930 930 ))) 931 931 |(% colspan="1" rowspan="5" style="width:143px" %)((( 932 - 933 - 934 - 935 - 936 - 937 937 AT+ROC=3,a,b,c,d,e 938 938 )))|(% style="width:160px" %)((( 939 - 940 - 941 -a: Set the detection interval 932 +**a:** Set the detection interval 942 942 )))|(% style="width:185px" %)((( 943 - 944 - 945 945 Range: 0~~65535s 946 946 ))) 947 -|(% style="width:160px" %)b: Set the IDC alarm trigger condition|(% style="width:185px" %)((( 948 - 949 - 950 -0: Less than the set IDC threshold, Alarm 951 - 952 -1: Greater than the set IDC threshold, Alarm 936 +|(% style="width:160px" %)**b:** Set the IDC alarm trigger condition|(% style="width:185px" %)((( 937 +**0:** Less than the set IDC threshold, Alarm 938 +**1:** Greater than the set IDC threshold, Alarm 953 953 ))) 954 954 |(% style="width:160px" %)((( 955 - 956 - 957 -c: IDC alarm threshold 941 +**c: ** IDC alarm threshold 958 958 )))|(% style="width:185px" %)((( 959 - 960 - 961 961 Unit: uA 962 962 ))) 963 -|(% style="width:160px" %)d: Set the VDC alarm trigger condition|(% style="width:185px" %)((( 964 - 965 - 966 -0: Less than the set VDC threshold, Alarm 967 - 968 -1: Greater than the set VDC threshold, Alarm 945 +|(% style="width:160px" %)**d:** Set the VDC alarm trigger condition|(% style="width:185px" %)((( 946 +**0:** Less than the set VDC threshold, Alarm 947 +**1:** Greater than the set VDC threshold, Alarm 969 969 ))) 970 -|(% style="width:160px" %)e: VDC alarm threshold|(% style="width:185px" %)Unit: mV 949 +|(% style="width:160px" %)**e:** VDC alarm threshold|(% style="width:185px" %)Unit: mV 971 971 972 972 Example: 973 973 974 -* AT+ROC=3,60,0,3000,0,5000 ~/~/The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated. 975 -* AT+ROC=3,180,1,3000,1,5000 ~/~/The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated. 976 -* AT+ROC=3,300,0,3000,1,5000 ~/~/The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated. 953 +* AT+ROC=3,60,0,3000,0,5000 ~/~/ The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated. 954 +* AT+ROC=3,180,1,3000,1,5000 ~/~/ The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated. 955 +* AT+ROC=3,300,0,3000,1,5000 ~/~/ The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated. 977 977 978 978 Downlink Command: 0x09 03 aa bb cc dd ee 979 979 ... ... @@ -992,9 +992,9 @@ 992 992 993 993 Example: 994 994 995 -* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,0,5000 996 -* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38 ~/~/Equal to AT+ROC=3,60,1,3000,1,5000 997 -* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,1,5000 974 +* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/ Equal to AT+ROC=3,60,0,3000,0,5000 975 +* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38 ~/~/ Equal to AT+ROC=3,60,1,3000,1,5000 976 +* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38 ~/~/ Equal to AT+ROC=3,60,0,3000,1,5000 998 998 999 999 Screenshot of parsing example in TTN: 1000 1000