Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/27 10:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -679,7 +679,6 @@ 679 679 )))|(% style="width:86px" %)Unix Time Stamp 680 680 681 681 682 - 683 683 IN1_pin_level & IN2_pin_level & Exti_pin_level & Exti_status: 684 684 685 685 [[image:image-20250117104847-4.png]] ... ... @@ -853,6 +853,7 @@ 853 853 854 854 ==== 2.8.2.1 Wave alarm mode ==== 855 855 855 + 856 856 Feature: By setting the detection period and a change value, the IDC/VDC variable is monitored whether it exceeds the set change value. If this change value is exceeded, the ROC uplink is sent and the comparison value is flushed. 857 857 858 858 * Change value: The amount by which the next detection value increases/decreases relative to the previous detection value. ... ... @@ -869,24 +869,21 @@ 869 869 |(% colspan="1" rowspan="4" style="width:143px" %)((( 870 870 AT+ROC=a,b,c,d 871 871 )))|(% style="width:154px" %)((( 872 -a: Enable or disable the ROC 872 +**a:** Enable or disable the ROC 873 873 )))|(% style="width:197px" %)((( 874 -0: off 875 -1: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 876 - 877 -2: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]). 874 +**0:** off 875 +**1:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 876 +**2:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]). 878 878 ))) 879 -|(% style="width:154px" %)b: Set the detection interval|(% style="width:197px" %)((( 880 - 881 - 878 +|(% style="width:154px" %)**b:** Set the detection interval|(% style="width:197px" %)((( 882 882 Range: 0~~65535s 883 883 ))) 884 -|(% style="width:154px" %)c: Setting the IDC change value|(% style="width:197px" %)Unit: uA 885 -|(% style="width:154px" %)d: Setting the VDC change value|(% style="width:197px" %)Unit: mV 881 +|(% style="width:154px" %)**c:** Setting the IDC change value|(% style="width:197px" %)Unit: uA 882 +|(% style="width:154px" %)**d:** Setting the VDC change value|(% style="width:197px" %)Unit: mV 886 886 887 887 Example: 888 888 889 -* AT+ROC=0,0,0,0 ~/~/The ROC function is not used. 886 +* AT+ROC=0,0,0,0 ~/~/ The ROC function is not used. 890 890 * AT+ROC=1,60,3000, 500 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink, and the comparison value is refreshed. 891 891 * AT+ROC=1,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. 892 892 * AT+ROC=2,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. In addition, if the change in the IDC does not exceed 3mA, then the ROC uplink is not sent, and the comparison value is not refreshed by the ROC uplink packet. However, if the device TDC time arrives, or if the user manually sends packets, then the IDC comparison value is also refreshed. ... ... @@ -905,9 +905,9 @@ 905 905 906 906 Example: 907 907 908 -* Downlink Payload: 09 01 00 3C 0B B8 01 F4 ~/~/Equal to AT+ROC=1,60,3000, 500 909 -* Downlink Payload: 09 01 00 3C 0B B8 00 00 ~/~/Equal to AT+ROC=1,60,3000,0 910 -* Downlink Payload: 09 02 00 3C 0B B8 00 00 ~/~/Equal to AT+ROC=2,60,3000,0 905 +* Downlink Payload: 09 01 00 3C 0B B8 01 F4 ~/~/ Equal to AT+ROC=1,60,3000, 500 906 +* Downlink Payload: 09 01 00 3C 0B B8 00 00 ~/~/ Equal to AT+ROC=1,60,3000,0 907 +* Downlink Payload: 09 02 00 3C 0B B8 00 00 ~/~/ Equal to AT+ROC=2,60,3000,0 911 911 912 912 Screenshot of parsing example in TTN: 913 913 ... ... @@ -918,6 +918,7 @@ 918 918 919 919 ==== 2.8.2.2 Over-threshold alarm mode ==== 920 920 918 + 921 921 Feature: Monitors whether the IDC/VDC exceeds the threshold by setting the detection period and threshold. Alarm if the threshold is exceeded. 922 922 923 923 AT Command: AT+ROC=3,a,b,c,d,e ... ... @@ -925,57 +925,36 @@ 925 925 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 926 926 |=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 160px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 185px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation 927 927 |(% style="width:143px" %)AT+ROC=?|(% style="width:160px" %)Show current ROC setting|(% style="width:185px" %)((( 928 - 929 - 930 930 0,0,0,0(default) 931 931 OK 932 932 ))) 933 933 |(% colspan="1" rowspan="5" style="width:143px" %)((( 934 - 935 - 936 - 937 - 938 - 939 939 AT+ROC=3,a,b,c,d,e 940 940 )))|(% style="width:160px" %)((( 941 - 942 - 943 -a: Set the detection interval 932 +**a:** Set the detection interval 944 944 )))|(% style="width:185px" %)((( 945 - 946 - 947 947 Range: 0~~65535s 948 948 ))) 949 -|(% style="width:160px" %)b: Set the IDC alarm trigger condition|(% style="width:185px" %)((( 950 - 951 - 952 -0: Less than the set IDC threshold, Alarm 953 - 954 -1: Greater than the set IDC threshold, Alarm 936 +|(% style="width:160px" %)**b:** Set the IDC alarm trigger condition|(% style="width:185px" %)((( 937 +**0:** Less than the set IDC threshold, Alarm 938 +**1:** Greater than the set IDC threshold, Alarm 955 955 ))) 956 956 |(% style="width:160px" %)((( 957 - 958 - 959 -c: IDC alarm threshold 941 +**c: ** IDC alarm threshold 960 960 )))|(% style="width:185px" %)((( 961 - 962 - 963 963 Unit: uA 964 964 ))) 965 -|(% style="width:160px" %)d: Set the VDC alarm trigger condition|(% style="width:185px" %)((( 966 - 967 - 968 -0: Less than the set VDC threshold, Alarm 969 - 970 -1: Greater than the set VDC threshold, Alarm 945 +|(% style="width:160px" %)**d:** Set the VDC alarm trigger condition|(% style="width:185px" %)((( 946 +**0:** Less than the set VDC threshold, Alarm 947 +**1:** Greater than the set VDC threshold, Alarm 971 971 ))) 972 -|(% style="width:160px" %)e: VDC alarm threshold|(% style="width:185px" %)Unit: mV 949 +|(% style="width:160px" %)**e:** VDC alarm threshold|(% style="width:185px" %)Unit: mV 973 973 974 974 Example: 975 975 976 -* AT+ROC=3,60,0,3000,0,5000 ~/~/The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated. 977 -* AT+ROC=3,180,1,3000,1,5000 ~/~/The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated. 978 -* AT+ROC=3,300,0,3000,1,5000 ~/~/The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated. 953 +* AT+ROC=3,60,0,3000,0,5000 ~/~/ The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated. 954 +* AT+ROC=3,180,1,3000,1,5000 ~/~/ The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated. 955 +* AT+ROC=3,300,0,3000,1,5000 ~/~/ The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated. 979 979 980 980 Downlink Command: 0x09 03 aa bb cc dd ee 981 981 ... ... @@ -994,9 +994,9 @@ 994 994 995 995 Example: 996 996 997 -* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,0,5000 998 -* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38 ~/~/Equal to AT+ROC=3,60,1,3000,1,5000 999 -* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,1,5000 974 +* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/ Equal to AT+ROC=3,60,0,3000,0,5000 975 +* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38 ~/~/ Equal to AT+ROC=3,60,1,3000,1,5000 976 +* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38 ~/~/ Equal to AT+ROC=3,60,0,3000,1,5000 1000 1000 1001 1001 Screenshot of parsing example in TTN: 1002 1002