... ... @@ -679,7 +679,6 @@
679 679  )))|(% style="width:86px" %)Unix Time Stamp
680 680  
681 681  
682 -
683 683  IN1_pin_level & IN2_pin_level & Exti_pin_level & Exti_status:
684 684  
685 685  [[image:image-20250117104847-4.png]]
... ... @@ -853,6 +853,7 @@
853 853  
854 854  ==== 2.8.2.1 Wave alarm mode ====
855 855  
855 +
856 856  Feature: By setting the detection period and a change value, the IDC/VDC variable is monitored whether it exceeds the set change value. If this change value is exceeded, the ROC uplink is sent and the comparison value is flushed.
857 857  
858 858  * Change value: The amount by which the next detection value increases/decreases relative to the previous detection value.
... ... @@ -863,46 +863,27 @@
863 863  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
864 864  |=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 154px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 197px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation
865 865  |(% style="width:143px" %)AT+ROC=?|(% style="width:154px" %)Show current ROC setting|(% style="width:197px" %)(((
866 -
867 -
868 868  0,0,0,0(default)
869 869  OK
870 870  )))
871 871  |(% colspan="1" rowspan="4" style="width:143px" %)(((
872 -
873 -
874 -
875 -
876 -
877 877  AT+ROC=a,b,c,d
878 878  )))|(% style="width:154px" %)(((
879 -
880 -
881 -
882 -
883 -
884 -
885 -
886 -a: Enable or disable the ROC
872 +**a:** Enable or disable the ROC
887 887  )))|(% style="width:197px" %)(((
888 -
889 -
890 -0: off
891 -1: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value.
892 -
893 -2: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]).
874 +**0:** off
875 +**1:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value.
876 +**2:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]).
894 894  )))
895 -|(% style="width:154px" %)b: Set the detection interval|(% style="width:197px" %)(((
896 -
897 -
878 +|(% style="width:154px" %)**b:** Set the detection interval|(% style="width:197px" %)(((
898 898  Range:  0~~65535s
899 899  )))
900 -|(% style="width:154px" %)c: Setting the IDC change value|(% style="width:197px" %)Unit: uA
901 -|(% style="width:154px" %)d: Setting the VDC change value|(% style="width:197px" %)Unit: mV
881 +|(% style="width:154px" %)**c:** Setting the IDC change value|(% style="width:197px" %)Unit: uA
882 +|(% style="width:154px" %)**d:** Setting the VDC change value|(% style="width:197px" %)Unit: mV
902 902  
903 903  Example:
904 904  
905 -* AT+ROC=0,0,0,0  ~/~/The ROC function is not used.
886 +* AT+ROC=0,0,0,0  ~/~/ The ROC function is not used.
906 906  * AT+ROC=1,60,3000, 500  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink, and the comparison value is refreshed.
907 907  * AT+ROC=1,60,3000,0  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage.
908 908  * AT+ROC=2,60,3000,0  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. In addition, if the change in the IDC does not exceed 3mA, then the ROC uplink is not sent, and the comparison value is not refreshed by the ROC uplink packet. However, if the device TDC time arrives, or if the user manually sends packets, then the IDC comparison value is also refreshed.
... ... @@ -921,9 +921,9 @@
921 921  
922 922  Example:
923 923  
924 -* Downlink Payload: 09 01 00 3C 0B B8 01 F4  ~/~/Equal to AT+ROC=1,60,3000, 500
925 -* Downlink Payload: 09 01 00 3C 0B B8 00 00  ~/~/Equal to AT+ROC=1,60,3000,0
926 -* Downlink Payload: 09 02 00 3C 0B B8 00 00  ~/~/Equal to AT+ROC=2,60,3000,0
905 +* Downlink Payload: 09 01 00 3C 0B B8 01 F4  ~/~/ Equal to AT+ROC=1,60,3000, 500
906 +* Downlink Payload: 09 01 00 3C 0B B8 00 00  ~/~/ Equal to AT+ROC=1,60,3000,0
907 +* Downlink Payload: 09 02 00 3C 0B B8 00 00  ~/~/ Equal to AT+ROC=2,60,3000,0
927 927  
928 928  Screenshot of parsing example in TTN:
929 929  
... ... @@ -934,6 +934,7 @@
934 934  
935 935  ==== 2.8.2.2 Over-threshold alarm mode ====
936 936  
918 +
937 937  Feature: Monitors whether the IDC/VDC exceeds the threshold by setting the detection period and threshold. Alarm if the threshold is exceeded.
938 938  
939 939  AT Command: AT+ROC=3,a,b,c,d,e
... ... @@ -941,8 +941,6 @@
941 941  (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
942 942  |=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 160px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 185px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation
943 943  |(% style="width:143px" %)AT+ROC=?|(% style="width:160px" %)Show current ROC setting|(% style="width:185px" %)(((
944 -
945 -
946 946  0,0,0,0(default)
947 947  OK
948 948  )))
... ... @@ -954,44 +954,32 @@
954 954  
955 955  AT+ROC=3,a,b,c,d,e
956 956  )))|(% style="width:160px" %)(((
957 -
958 -
959 -a: Set the detection interval
937 +**a:** Set the detection interval
960 960  )))|(% style="width:185px" %)(((
961 -
962 -
963 963  Range:  0~~65535s
964 964  )))
965 -|(% style="width:160px" %)b: Set the IDC alarm trigger condition|(% style="width:185px" %)(((
966 -
941 +|(% style="width:160px" %)**b:** Set the IDC alarm trigger condition|(% style="width:185px" %)(((
942 +**0:** Less than the set IDC threshold, Alarm
967 967  
968 -0: Less than the set IDC threshold, Alarm
969 -
970 -1: Greater than the set IDC threshold, Alarm
944 +**1:** Greater than the set IDC threshold, Alarm
971 971  )))
972 972  |(% style="width:160px" %)(((
973 -
974 -
975 -c:  IDC alarm threshold
947 +**c: ** IDC alarm threshold
976 976  )))|(% style="width:185px" %)(((
977 -
978 -
979 979  Unit: uA
980 980  )))
981 -|(% style="width:160px" %)d: Set the VDC alarm trigger condition|(% style="width:185px" %)(((
982 -
951 +|(% style="width:160px" %)**d:** Set the VDC alarm trigger condition|(% style="width:185px" %)(((
952 +**0:** Less than the set VDC threshold, Alarm
983 983  
984 -0: Less than the set VDC threshold, Alarm
985 -
986 -1: Greater than the set VDC threshold, Alarm
954 +**1:** Greater than the set VDC threshold, Alarm
987 987  )))
988 -|(% style="width:160px" %)e: VDC alarm threshold|(% style="width:185px" %)Unit: mV
956 +|(% style="width:160px" %)**e:** VDC alarm threshold|(% style="width:185px" %)Unit: mV
989 989  
990 990  Example:
991 991  
992 -* AT+ROC=3,60,0,3000,0,5000  ~/~/The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated.
993 -* AT+ROC=3,180,1,3000,1,5000  ~/~/The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated.
994 -* AT+ROC=3,300,0,3000,1,5000  ~/~/The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated.
960 +* AT+ROC=3,60,0,3000,0,5000  ~/~/ The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated.
961 +* AT+ROC=3,180,1,3000,1,5000  ~/~/ The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated.
962 +* AT+ROC=3,300,0,3000,1,5000  ~/~/ The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated.
995 995  
996 996  Downlink Command: 0x09 03 aa bb cc dd ee
997 997  
... ... @@ -1010,9 +1010,9 @@
1010 1010  
1011 1011  Example:
1012 1012  
1013 -* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,0,5000
1014 -* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38  ~/~/Equal to AT+ROC=3,60,1,3000,1,5000
1015 -* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38  ~/~/Equal to AT+ROC=3,60,0,3000,1,5000
981 +* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/ Equal to AT+ROC=3,60,0,3000,0,5000
982 +* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38  ~/~/ Equal to AT+ROC=3,60,1,3000,1,5000
983 +* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38  ~/~/ Equal to AT+ROC=3,60,0,3000,1,5000
1016 1016  
1017 1017  Screenshot of parsing example in TTN:
1018 1018  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved