Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/27 10:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -645,8 +645,6 @@ 645 645 |=(% colspan="4" style="width: 160px; background-color:#4F81BD;color:white" %)Downlink Command to poll Open/Close status (0x31) 646 646 |(% style="background-color:#f2f2f2; width:67px" %)1byte|(% style="background-color:#f2f2f2; width:145px" %)4bytes|(% style="background-color:#f2f2f2; width:133px" %)4bytes|(% style="background-color:#f2f2f2; width:163px" %)1byte 647 647 |(% style="background-color:#f2f2f2; width:67px" %)31|(% style="background-color:#f2f2f2; width:145px" %)Timestamp start|(% style="background-color:#f2f2f2; width:133px" %)((( 648 - 649 - 650 650 Timestamp end 651 651 )))|(% style="background-color:#f2f2f2; width:163px" %)Uplink Interval 652 652 ... ... @@ -679,6 +679,8 @@ 679 679 )))|(% style="width:201px" %)((( 680 680 IN1_pin_level& IN2_pin_level& Exti_pin_level&Exti_status 681 681 )))|(% style="width:86px" %)Unix Time Stamp 680 + 681 + 682 682 IN1_pin_level & IN2_pin_level & Exti_pin_level & Exti_status: 683 683 684 684 [[image:image-20250117104847-4.png]] ... ... @@ -784,13 +784,9 @@ 784 784 785 785 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 786 786 |(% style="background-color:#4f81bd; color:white; width:97px" %)((( 787 - 788 - 789 789 Size(bytes) 790 790 )))|(% style="background-color:#4f81bd; color:white; width:48px" %)2|(% style="background-color:#4f81bd; color:white; width:71px" %)2|(% style="background-color:#4f81bd; color:white; width:98px" %)2|(% style="background-color:#4f81bd; color:white; width:73px" %)2|(% style="background-color:#4f81bd; color:white; width:122px" %)1 791 -|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)((( 792 - 793 - 789 +|(% style="width:98px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)((( 794 794 [[IN1 &IN2 Interrupt flag>>||anchor="H2.3.7IN126IN226INTpin"]] & ROC_flag 795 795 ))) 796 796 ... ... @@ -856,6 +856,7 @@ 856 856 857 857 ==== 2.8.2.1 Wave alarm mode ==== 858 858 855 + 859 859 Feature: By setting the detection period and a change value, the IDC/VDC variable is monitored whether it exceeds the set change value. If this change value is exceeded, the ROC uplink is sent and the comparison value is flushed. 860 860 861 861 * Change value: The amount by which the next detection value increases/decreases relative to the previous detection value. ... ... @@ -864,48 +864,29 @@ 864 864 AT Command: AT+ROC 865 865 866 866 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 867 -|=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 154px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 19 7px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation864 +|=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 154px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 193px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation 868 868 |(% style="width:143px" %)AT+ROC=?|(% style="width:154px" %)Show current ROC setting|(% style="width:197px" %)((( 869 - 870 - 871 871 0,0,0,0(default) 872 872 OK 873 873 ))) 874 874 |(% colspan="1" rowspan="4" style="width:143px" %)((( 875 - 876 - 877 - 878 - 879 - 880 880 AT+ROC=a,b,c,d 881 881 )))|(% style="width:154px" %)((( 882 - 883 - 884 - 885 - 886 - 887 - 888 - 889 -a: Enable or disable the ROC 872 +**a:** Enable or disable the ROC 890 890 )))|(% style="width:197px" %)((( 891 - 892 - 893 -0: off 894 -1: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 895 - 896 -2: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]). 874 +**0:** off 875 +**1:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 876 +**2:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]). 897 897 ))) 898 -|(% style="width:154px" %)b: Set the detection interval|(% style="width:197px" %)((( 899 - 900 - 878 +|(% style="width:154px" %)**b:** Set the detection interval|(% style="width:197px" %)((( 901 901 Range: 0~~65535s 902 902 ))) 903 -|(% style="width:154px" %)c: Setting the IDC change value|(% style="width:197px" %)Unit: uA 904 -|(% style="width:154px" %)d: Setting the VDC change value|(% style="width:197px" %)Unit: mV 881 +|(% style="width:154px" %)**c:** Setting the IDC change value|(% style="width:197px" %)Unit: uA 882 +|(% style="width:154px" %)**d:** Setting the VDC change value|(% style="width:197px" %)Unit: mV 905 905 906 906 Example: 907 907 908 -* AT+ROC=0,0,0,0 ~/~/The ROC function is not used. 886 +* AT+ROC=0,0,0,0 ~/~/ The ROC function is not used. 909 909 * AT+ROC=1,60,3000, 500 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink, and the comparison value is refreshed. 910 910 * AT+ROC=1,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. 911 911 * AT+ROC=2,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. In addition, if the change in the IDC does not exceed 3mA, then the ROC uplink is not sent, and the comparison value is not refreshed by the ROC uplink packet. However, if the device TDC time arrives, or if the user manually sends packets, then the IDC comparison value is also refreshed. ... ... @@ -924,9 +924,9 @@ 924 924 925 925 Example: 926 926 927 -* Downlink Payload: 09 01 00 3C 0B B8 01 F4 ~/~/Equal to AT+ROC=1,60,3000, 500 928 -* Downlink Payload: 09 01 00 3C 0B B8 00 00 ~/~/Equal to AT+ROC=1,60,3000,0 929 -* Downlink Payload: 09 02 00 3C 0B B8 00 00 ~/~/Equal to AT+ROC=2,60,3000,0 905 +* Downlink Payload: 09 01 00 3C 0B B8 01 F4 ~/~/ Equal to AT+ROC=1,60,3000, 500 906 +* Downlink Payload: 09 01 00 3C 0B B8 00 00 ~/~/ Equal to AT+ROC=1,60,3000,0 907 +* Downlink Payload: 09 02 00 3C 0B B8 00 00 ~/~/ Equal to AT+ROC=2,60,3000,0 930 930 931 931 Screenshot of parsing example in TTN: 932 932 ... ... @@ -937,64 +937,44 @@ 937 937 938 938 ==== 2.8.2.2 Over-threshold alarm mode ==== 939 939 918 + 940 940 Feature: Monitors whether the IDC/VDC exceeds the threshold by setting the detection period and threshold. Alarm if the threshold is exceeded. 941 941 942 942 AT Command: AT+ROC=3,a,b,c,d,e 943 943 944 944 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 945 -|=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 160px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 18 5px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation924 +|=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 160px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 187px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation 946 946 |(% style="width:143px" %)AT+ROC=?|(% style="width:160px" %)Show current ROC setting|(% style="width:185px" %)((( 947 - 948 - 949 949 0,0,0,0(default) 950 950 OK 951 951 ))) 952 952 |(% colspan="1" rowspan="5" style="width:143px" %)((( 953 - 954 - 955 - 956 - 957 - 958 958 AT+ROC=3,a,b,c,d,e 959 959 )))|(% style="width:160px" %)((( 960 - 961 - 962 -a: Set the detection interval 932 +**a:** Set the detection interval 963 963 )))|(% style="width:185px" %)((( 964 - 965 - 966 966 Range: 0~~65535s 967 967 ))) 968 -|(% style="width:160px" %)b: Set the IDC alarm trigger condition|(% style="width:185px" %)((( 969 - 970 - 971 -0: Less than the set IDC threshold, Alarm 972 - 973 -1: Greater than the set IDC threshold, Alarm 936 +|(% style="width:160px" %)**b:** Set the IDC alarm trigger condition|(% style="width:185px" %)((( 937 +**0:** Less than the set IDC threshold, Alarm 938 +**1:** Greater than the set IDC threshold, Alarm 974 974 ))) 975 975 |(% style="width:160px" %)((( 976 - 977 - 978 -c: IDC alarm threshold 941 +**c: ** IDC alarm threshold 979 979 )))|(% style="width:185px" %)((( 980 - 981 - 982 982 Unit: uA 983 983 ))) 984 -|(% style="width:160px" %)d: Set the VDC alarm trigger condition|(% style="width:185px" %)((( 985 - 986 - 987 -0: Less than the set VDC threshold, Alarm 988 - 989 -1: Greater than the set VDC threshold, Alarm 945 +|(% style="width:160px" %)**d:** Set the VDC alarm trigger condition|(% style="width:185px" %)((( 946 +**0:** Less than the set VDC threshold, Alarm 947 +**1:** Greater than the set VDC threshold, Alarm 990 990 ))) 991 -|(% style="width:160px" %)e: VDC alarm threshold|(% style="width:185px" %)Unit: mV 949 +|(% style="width:160px" %)**e:** VDC alarm threshold|(% style="width:185px" %)Unit: mV 992 992 993 993 Example: 994 994 995 -* AT+ROC=3,60,0,3000,0,5000 ~/~/The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated. 996 -* AT+ROC=3,180,1,3000,1,5000 ~/~/The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated. 997 -* AT+ROC=3,300,0,3000,1,5000 ~/~/The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated. 953 +* AT+ROC=3,60,0,3000,0,5000 ~/~/ The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated. 954 +* AT+ROC=3,180,1,3000,1,5000 ~/~/ The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated. 955 +* AT+ROC=3,300,0,3000,1,5000 ~/~/ The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated. 998 998 999 999 Downlink Command: 0x09 03 aa bb cc dd ee 1000 1000 ... ... @@ -1013,9 +1013,9 @@ 1013 1013 1014 1014 Example: 1015 1015 1016 -* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,0,5000 1017 -* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38 ~/~/Equal to AT+ROC=3,60,1,3000,1,5000 1018 -* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,1,5000 974 +* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/ Equal to AT+ROC=3,60,0,3000,0,5000 975 +* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38 ~/~/ Equal to AT+ROC=3,60,1,3000,1,5000 976 +* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38 ~/~/ Equal to AT+ROC=3,60,0,3000,1,5000 1019 1019 1020 1020 Screenshot of parsing example in TTN: 1021 1021 ... ... @@ -1069,18 +1069,14 @@ 1069 1069 1070 1070 AT Command: AT+TDC 1071 1071 1072 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:510px" %)1030 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1073 1073 |=(% style="width: 160px; background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 160px; background-color:#4F81BD;color:white" %)Function|=(% style="width: 190px;background-color:#4F81BD;color:white" %)Response 1074 1074 |(% style="background-color:#f2f2f2; width:157px" %)AT+TDC=?|(% style="background-color:#f2f2f2; width:166px" %)Show current transmit Interval|(% style="background-color:#f2f2f2" %)((( 1075 - 1076 - 1077 1077 30000 1078 1078 OK 1079 1079 the interval is 30000ms = 30s 1080 1080 ))) 1081 1081 |(% style="background-color:#f2f2f2; width:157px" %)AT+TDC=60000|(% style="background-color:#f2f2f2; width:166px" %)Set Transmit Interval|(% style="background-color:#f2f2f2" %)((( 1082 - 1083 - 1084 1084 OK 1085 1085 Set transmit interval to 60000ms = 60 seconds 1086 1086 ))) ... ... @@ -1101,18 +1101,14 @@ 1101 1101 1102 1102 AT Command: AT+INTMOD 1103 1103 1104 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:510px" %)1058 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1105 1105 |=(% style="width: 154px;background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 196px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 160px;background-color:#4F81BD;color:white" %)Response 1106 1106 |(% style="background-color:#f2f2f2; width:154px" %)AT+INTMOD=?|(% style="background-color:#f2f2f2; width:196px" %)Show current interrupt mode|(% style="background-color:#f2f2f2; width:157px" %)((( 1107 - 1108 - 1109 1109 0 1110 1110 OK 1111 1111 the mode is 0 =Disable Interrupt 1112 1112 ))) 1113 1113 |(% style="background-color:#f2f2f2; width:154px" %)AT+INTMOD=2|(% style="background-color:#f2f2f2; width:196px" %)((( 1114 - 1115 - 1116 1116 Set Transmit Interval 1117 1117 0. (Disable Interrupt), 1118 1118 ~1. (Trigger by rising and falling edge) ... ... @@ -1136,72 +1136,52 @@ 1136 1136 1137 1137 AT Command: AT+3V3T 1138 1138 1139 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:474px" %)1089 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:474px" %) 1140 1140 |=(% style="width: 154px;background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 201px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 119px;background-color:#4F81BD;color:white" %)Response 1141 1141 |(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=?|(% style="background-color:#f2f2f2; width:201px" %)Show 3V3 open time.|(% style="background-color:#f2f2f2; width:116px" %)((( 1142 - 1143 - 1144 1144 0 1145 1145 OK 1146 1146 ))) 1147 1147 |(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=0|(% style="background-color:#f2f2f2; width:201px" %)Normally open 3V3 power supply.|(% style="background-color:#f2f2f2; width:116px" %)((( 1148 - 1149 - 1150 1150 OK 1151 1151 default setting 1152 1152 ))) 1153 1153 |(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=1000|(% style="background-color:#f2f2f2; width:201px" %)Close after a delay of 1000 milliseconds.|(% style="background-color:#f2f2f2; width:116px" %)((( 1154 - 1155 - 1156 1156 OK 1157 1157 ))) 1158 1158 |(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=65535|(% style="background-color:#f2f2f2; width:201px" %)Normally closed 3V3 power supply.|(% style="background-color:#f2f2f2; width:116px" %)((( 1159 - 1160 - 1161 1161 OK 1162 1162 ))) 1163 1163 1164 1164 AT Command: AT+5VT 1165 1165 1166 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:470px" %)1108 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:470px" %) 1167 1167 |=(% style="width: 155px;background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 196px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 119px;background-color:#4F81BD;color:white" %)Response 1168 1168 |(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=?|(% style="background-color:#f2f2f2; width:196px" %)Show 5V open time.|(% style="background-color:#f2f2f2; width:114px" %)((( 1169 - 1170 - 1171 1171 0 1172 1172 OK 1173 1173 ))) 1174 1174 |(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=0|(% style="background-color:#f2f2f2; width:196px" %)Normally closed 5V power supply.|(% style="background-color:#f2f2f2; width:114px" %)((( 1175 - 1176 - 1177 1177 OK 1178 1178 default setting 1179 1179 ))) 1180 1180 |(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=1000|(% style="background-color:#f2f2f2; width:196px" %)Close after a delay of 1000 milliseconds.|(% style="background-color:#f2f2f2; width:114px" %)((( 1181 - 1182 - 1183 1183 OK 1184 1184 ))) 1185 1185 |(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=65535|(% style="background-color:#f2f2f2; width:196px" %)Normally open 5V power supply.|(% style="background-color:#f2f2f2; width:114px" %)((( 1186 - 1187 - 1188 1188 OK 1189 1189 ))) 1190 1190 1191 1191 AT Command: AT+12VT 1192 1192 1193 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:443px" %)1127 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:443px" %) 1194 1194 |=(% style="width: 156px;background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 199px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 88px;background-color:#4F81BD;color:white" %)Response 1195 1195 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)((( 1196 - 1197 - 1198 1198 0 1199 1199 OK 1200 1200 ))) 1201 1201 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=0|(% style="background-color:#f2f2f2; width:199px" %)Normally closed 12V power supply.|(% style="background-color:#f2f2f2; width:83px" %)OK 1202 1202 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=500|(% style="background-color:#f2f2f2; width:199px" %)Close after a delay of 500 milliseconds.|(% style="background-color:#f2f2f2; width:83px" %)((( 1203 - 1204 - 1205 1205 OK 1206 1206 ))) 1207 1207 ... ... @@ -1257,8 +1257,6 @@ 1257 1257 OK 1258 1258 |(% style="background-color:#f2f2f2; width:154px" %)AT+PROBE=0003|(% style="background-color:#f2f2f2; width:269px" %)Set water depth sensor mode, 3m type.|(% style="background-color:#f2f2f2" %)OK 1259 1259 |(% style="background-color:#f2f2f2; width:154px" %)((( 1260 - 1261 - 1262 1262 AT+PROBE=000A 1263 1263 )))|(% style="background-color:#f2f2f2; width:269px" %)Set water depth sensor mode, 10m type.|(% style="background-color:#f2f2f2" %)OK 1264 1264 |(% style="background-color:#f2f2f2; width:154px" %)AT+PROBE=0064|(% style="background-color:#f2f2f2; width:269px" %)Set water depth sensor mode, 100m type.|(% style="background-color:#f2f2f2" %)OK ... ... @@ -1288,15 +1288,12 @@ 1288 1288 bb: Each collection interval (s), the value is 1~~65535 1289 1289 cc: the number of collection times, the value is 1~~120 1290 1290 1291 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:510px" %)1219 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1292 1292 |(% style="background-color:#4f81bd; color:white; width:160px" %)Command Example|(% style="background-color:#4f81bd; color:white; width:215px" %)Function|(% style="background-color:#4f81bd; color:white" %)Response 1293 1293 |(% style="background-color:#f2f2f2; width:160px" %)AT+STDC=?|(% style="background-color:#f2f2f2; width:215px" %)Get the mode of multiple acquisitions and one uplink.|(% style="background-color:#f2f2f2" %)1,10,18 1294 1294 OK 1295 1295 |(% style="background-color:#f2f2f2; width:160px" %)AT+STDC=1,10,18|(% style="background-color:#f2f2f2; width:215px" %)Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|(% style="background-color:#f2f2f2" %)((( 1296 - 1297 - 1298 1298 Attention:Take effect after ATZ 1299 - 1300 1300 OK 1301 1301 ))) 1302 1302 |(% style="background-color:#f2f2f2; width:160px" %)AT+STDC=0, 0,0|(% style="background-color:#f2f2f2; width:215px" %)((( ... ... @@ -1306,10 +1306,7 @@ 1306 1306 1307 1307 1308 1308 )))|(% style="background-color:#f2f2f2" %)((( 1309 - 1310 - 1311 1311 Attention:Take effect after ATZ 1312 - 1313 1313 OK 1314 1314 ))) 1315 1315