Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/27 10:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -645,8 +645,6 @@ 645 645 |=(% colspan="4" style="width: 160px; background-color:#4F81BD;color:white" %)Downlink Command to poll Open/Close status (0x31) 646 646 |(% style="background-color:#f2f2f2; width:67px" %)1byte|(% style="background-color:#f2f2f2; width:145px" %)4bytes|(% style="background-color:#f2f2f2; width:133px" %)4bytes|(% style="background-color:#f2f2f2; width:163px" %)1byte 647 647 |(% style="background-color:#f2f2f2; width:67px" %)31|(% style="background-color:#f2f2f2; width:145px" %)Timestamp start|(% style="background-color:#f2f2f2; width:133px" %)((( 648 - 649 - 650 650 Timestamp end 651 651 )))|(% style="background-color:#f2f2f2; width:163px" %)Uplink Interval 652 652 ... ... @@ -671,23 +671,16 @@ 671 671 Size(bytes) 672 672 )))|=(% style="width: 70px; background-color:#4F81BD;color:white" %)2|=(% style="width: 70px; background-color:#4F81BD;color:white" %)2|=(% style="width: 80px; background-color: rgb(79, 129, 189); color: white;" %)2|=(% style="width: 150px; background-color: rgb(79, 129, 189); color: white;" %)1|=(% style="width: 80px; background-color: rgb(79, 129, 189); color: white;" %)4 673 673 |(% style="width:103px" %)Value|(% style="width:68px" %)((( 674 - 675 - 676 676 Probe_mod 677 677 )))|(% style="width:104px" %)((( 678 - 679 - 680 680 VDC_intput_V 681 681 )))|(% style="width:83px" %)((( 682 - 683 - 684 684 IDC_intput_mA 685 685 )))|(% style="width:201px" %)((( 686 - 687 - 688 688 IN1_pin_level& IN2_pin_level& Exti_pin_level&Exti_status 689 689 )))|(% style="width:86px" %)Unix Time Stamp 690 690 681 + 691 691 IN1_pin_level & IN2_pin_level & Exti_pin_level & Exti_status: 692 692 693 693 [[image:image-20250117104847-4.png]] ... ... @@ -793,13 +793,9 @@ 793 793 794 794 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 795 795 |(% style="background-color:#4f81bd; color:white; width:97px" %)((( 796 - 797 - 798 798 Size(bytes) 799 799 )))|(% style="background-color:#4f81bd; color:white; width:48px" %)2|(% style="background-color:#4f81bd; color:white; width:71px" %)2|(% style="background-color:#4f81bd; color:white; width:98px" %)2|(% style="background-color:#4f81bd; color:white; width:73px" %)2|(% style="background-color:#4f81bd; color:white; width:122px" %)1 800 -|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)((( 801 - 802 - 789 +|(% style="width:98px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)((( 803 803 [[IN1 &IN2 Interrupt flag>>||anchor="H2.3.7IN126IN226INTpin"]] & ROC_flag 804 804 ))) 805 805 ... ... @@ -865,6 +865,7 @@ 865 865 866 866 ==== 2.8.2.1 Wave alarm mode ==== 867 867 855 + 868 868 Feature: By setting the detection period and a change value, the IDC/VDC variable is monitored whether it exceeds the set change value. If this change value is exceeded, the ROC uplink is sent and the comparison value is flushed. 869 869 870 870 * Change value: The amount by which the next detection value increases/decreases relative to the previous detection value. ... ... @@ -873,48 +873,29 @@ 873 873 AT Command: AT+ROC 874 874 875 875 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 876 -|=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 154px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 19 7px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation864 +|=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 154px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 193px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation 877 877 |(% style="width:143px" %)AT+ROC=?|(% style="width:154px" %)Show current ROC setting|(% style="width:197px" %)((( 878 - 879 - 880 880 0,0,0,0(default) 881 881 OK 882 882 ))) 883 883 |(% colspan="1" rowspan="4" style="width:143px" %)((( 884 - 885 - 886 - 887 - 888 - 889 889 AT+ROC=a,b,c,d 890 890 )))|(% style="width:154px" %)((( 891 - 892 - 893 - 894 - 895 - 896 - 897 - 898 -a: Enable or disable the ROC 872 +**a:** Enable or disable the ROC 899 899 )))|(% style="width:197px" %)((( 900 - 901 - 902 -0: off 903 -1: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 904 - 905 -2: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]). 874 +**0:** off 875 +**1:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 876 +**2:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]). 906 906 ))) 907 -|(% style="width:154px" %)b: Set the detection interval|(% style="width:197px" %)((( 908 - 909 - 878 +|(% style="width:154px" %)**b:** Set the detection interval|(% style="width:197px" %)((( 910 910 Range: 0~~65535s 911 911 ))) 912 -|(% style="width:154px" %)c: Setting the IDC change value|(% style="width:197px" %)Unit: uA 913 -|(% style="width:154px" %)d: Setting the VDC change value|(% style="width:197px" %)Unit: mV 881 +|(% style="width:154px" %)**c:** Setting the IDC change value|(% style="width:197px" %)Unit: uA 882 +|(% style="width:154px" %)**d:** Setting the VDC change value|(% style="width:197px" %)Unit: mV 914 914 915 915 Example: 916 916 917 -* AT+ROC=0,0,0,0 ~/~/The ROC function is not used. 886 +* AT+ROC=0,0,0,0 ~/~/ The ROC function is not used. 918 918 * AT+ROC=1,60,3000, 500 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink, and the comparison value is refreshed. 919 919 * AT+ROC=1,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. 920 920 * AT+ROC=2,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. In addition, if the change in the IDC does not exceed 3mA, then the ROC uplink is not sent, and the comparison value is not refreshed by the ROC uplink packet. However, if the device TDC time arrives, or if the user manually sends packets, then the IDC comparison value is also refreshed. ... ... @@ -933,9 +933,9 @@ 933 933 934 934 Example: 935 935 936 -* Downlink Payload: 09 01 00 3C 0B B8 01 F4 ~/~/Equal to AT+ROC=1,60,3000, 500 937 -* Downlink Payload: 09 01 00 3C 0B B8 00 00 ~/~/Equal to AT+ROC=1,60,3000,0 938 -* Downlink Payload: 09 02 00 3C 0B B8 00 00 ~/~/Equal to AT+ROC=2,60,3000,0 905 +* Downlink Payload: 09 01 00 3C 0B B8 01 F4 ~/~/ Equal to AT+ROC=1,60,3000, 500 906 +* Downlink Payload: 09 01 00 3C 0B B8 00 00 ~/~/ Equal to AT+ROC=1,60,3000,0 907 +* Downlink Payload: 09 02 00 3C 0B B8 00 00 ~/~/ Equal to AT+ROC=2,60,3000,0 939 939 940 940 Screenshot of parsing example in TTN: 941 941 ... ... @@ -946,64 +946,44 @@ 946 946 947 947 ==== 2.8.2.2 Over-threshold alarm mode ==== 948 948 918 + 949 949 Feature: Monitors whether the IDC/VDC exceeds the threshold by setting the detection period and threshold. Alarm if the threshold is exceeded. 950 950 951 951 AT Command: AT+ROC=3,a,b,c,d,e 952 952 953 953 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 954 -|=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 160px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 18 5px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation924 +|=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 160px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 187px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation 955 955 |(% style="width:143px" %)AT+ROC=?|(% style="width:160px" %)Show current ROC setting|(% style="width:185px" %)((( 956 - 957 - 958 958 0,0,0,0(default) 959 959 OK 960 960 ))) 961 961 |(% colspan="1" rowspan="5" style="width:143px" %)((( 962 - 963 - 964 - 965 - 966 - 967 967 AT+ROC=3,a,b,c,d,e 968 968 )))|(% style="width:160px" %)((( 969 - 970 - 971 -a: Set the detection interval 932 +**a:** Set the detection interval 972 972 )))|(% style="width:185px" %)((( 973 - 974 - 975 975 Range: 0~~65535s 976 976 ))) 977 -|(% style="width:160px" %)b: Set the IDC alarm trigger condition|(% style="width:185px" %)((( 978 - 979 - 980 -0: Less than the set IDC threshold, Alarm 981 - 982 -1: Greater than the set IDC threshold, Alarm 936 +|(% style="width:160px" %)**b:** Set the IDC alarm trigger condition|(% style="width:185px" %)((( 937 +**0:** Less than the set IDC threshold, Alarm 938 +**1:** Greater than the set IDC threshold, Alarm 983 983 ))) 984 984 |(% style="width:160px" %)((( 985 - 986 - 987 -c: IDC alarm threshold 941 +**c: ** IDC alarm threshold 988 988 )))|(% style="width:185px" %)((( 989 - 990 - 991 991 Unit: uA 992 992 ))) 993 -|(% style="width:160px" %)d: Set the VDC alarm trigger condition|(% style="width:185px" %)((( 994 - 995 - 996 -0: Less than the set VDC threshold, Alarm 997 - 998 -1: Greater than the set VDC threshold, Alarm 945 +|(% style="width:160px" %)**d:** Set the VDC alarm trigger condition|(% style="width:185px" %)((( 946 +**0:** Less than the set VDC threshold, Alarm 947 +**1:** Greater than the set VDC threshold, Alarm 999 999 ))) 1000 -|(% style="width:160px" %)e: VDC alarm threshold|(% style="width:185px" %)Unit: mV 949 +|(% style="width:160px" %)**e:** VDC alarm threshold|(% style="width:185px" %)Unit: mV 1001 1001 1002 1002 Example: 1003 1003 1004 -* AT+ROC=3,60,0,3000,0,5000 ~/~/The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated. 1005 -* AT+ROC=3,180,1,3000,1,5000 ~/~/The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated. 1006 -* AT+ROC=3,300,0,3000,1,5000 ~/~/The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated. 953 +* AT+ROC=3,60,0,3000,0,5000 ~/~/ The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated. 954 +* AT+ROC=3,180,1,3000,1,5000 ~/~/ The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated. 955 +* AT+ROC=3,300,0,3000,1,5000 ~/~/ The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated. 1007 1007 1008 1008 Downlink Command: 0x09 03 aa bb cc dd ee 1009 1009 ... ... @@ -1022,9 +1022,9 @@ 1022 1022 1023 1023 Example: 1024 1024 1025 -* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,0,5000 1026 -* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38 ~/~/Equal to AT+ROC=3,60,1,3000,1,5000 1027 -* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,1,5000 974 +* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/ Equal to AT+ROC=3,60,0,3000,0,5000 975 +* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38 ~/~/ Equal to AT+ROC=3,60,1,3000,1,5000 976 +* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38 ~/~/ Equal to AT+ROC=3,60,0,3000,1,5000 1028 1028 1029 1029 Screenshot of parsing example in TTN: 1030 1030 ... ... @@ -1078,18 +1078,14 @@ 1078 1078 1079 1079 AT Command: AT+TDC 1080 1080 1081 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:510px" %)1030 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1082 1082 |=(% style="width: 160px; background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 160px; background-color:#4F81BD;color:white" %)Function|=(% style="width: 190px;background-color:#4F81BD;color:white" %)Response 1083 1083 |(% style="background-color:#f2f2f2; width:157px" %)AT+TDC=?|(% style="background-color:#f2f2f2; width:166px" %)Show current transmit Interval|(% style="background-color:#f2f2f2" %)((( 1084 - 1085 - 1086 1086 30000 1087 1087 OK 1088 1088 the interval is 30000ms = 30s 1089 1089 ))) 1090 1090 |(% style="background-color:#f2f2f2; width:157px" %)AT+TDC=60000|(% style="background-color:#f2f2f2; width:166px" %)Set Transmit Interval|(% style="background-color:#f2f2f2" %)((( 1091 - 1092 - 1093 1093 OK 1094 1094 Set transmit interval to 60000ms = 60 seconds 1095 1095 ))) ... ... @@ -1110,18 +1110,14 @@ 1110 1110 1111 1111 AT Command: AT+INTMOD 1112 1112 1113 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:510px" %)1058 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1114 1114 |=(% style="width: 154px;background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 196px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 160px;background-color:#4F81BD;color:white" %)Response 1115 1115 |(% style="background-color:#f2f2f2; width:154px" %)AT+INTMOD=?|(% style="background-color:#f2f2f2; width:196px" %)Show current interrupt mode|(% style="background-color:#f2f2f2; width:157px" %)((( 1116 - 1117 - 1118 1118 0 1119 1119 OK 1120 1120 the mode is 0 =Disable Interrupt 1121 1121 ))) 1122 1122 |(% style="background-color:#f2f2f2; width:154px" %)AT+INTMOD=2|(% style="background-color:#f2f2f2; width:196px" %)((( 1123 - 1124 - 1125 1125 Set Transmit Interval 1126 1126 0. (Disable Interrupt), 1127 1127 ~1. (Trigger by rising and falling edge) ... ... @@ -1145,72 +1145,52 @@ 1145 1145 1146 1146 AT Command: AT+3V3T 1147 1147 1148 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:474px" %)1089 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:474px" %) 1149 1149 |=(% style="width: 154px;background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 201px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 119px;background-color:#4F81BD;color:white" %)Response 1150 1150 |(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=?|(% style="background-color:#f2f2f2; width:201px" %)Show 3V3 open time.|(% style="background-color:#f2f2f2; width:116px" %)((( 1151 - 1152 - 1153 1153 0 1154 1154 OK 1155 1155 ))) 1156 1156 |(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=0|(% style="background-color:#f2f2f2; width:201px" %)Normally open 3V3 power supply.|(% style="background-color:#f2f2f2; width:116px" %)((( 1157 - 1158 - 1159 1159 OK 1160 1160 default setting 1161 1161 ))) 1162 1162 |(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=1000|(% style="background-color:#f2f2f2; width:201px" %)Close after a delay of 1000 milliseconds.|(% style="background-color:#f2f2f2; width:116px" %)((( 1163 - 1164 - 1165 1165 OK 1166 1166 ))) 1167 1167 |(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=65535|(% style="background-color:#f2f2f2; width:201px" %)Normally closed 3V3 power supply.|(% style="background-color:#f2f2f2; width:116px" %)((( 1168 - 1169 - 1170 1170 OK 1171 1171 ))) 1172 1172 1173 1173 AT Command: AT+5VT 1174 1174 1175 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:470px" %)1108 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:470px" %) 1176 1176 |=(% style="width: 155px;background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 196px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 119px;background-color:#4F81BD;color:white" %)Response 1177 1177 |(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=?|(% style="background-color:#f2f2f2; width:196px" %)Show 5V open time.|(% style="background-color:#f2f2f2; width:114px" %)((( 1178 - 1179 - 1180 1180 0 1181 1181 OK 1182 1182 ))) 1183 1183 |(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=0|(% style="background-color:#f2f2f2; width:196px" %)Normally closed 5V power supply.|(% style="background-color:#f2f2f2; width:114px" %)((( 1184 - 1185 - 1186 1186 OK 1187 1187 default setting 1188 1188 ))) 1189 1189 |(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=1000|(% style="background-color:#f2f2f2; width:196px" %)Close after a delay of 1000 milliseconds.|(% style="background-color:#f2f2f2; width:114px" %)((( 1190 - 1191 - 1192 1192 OK 1193 1193 ))) 1194 1194 |(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=65535|(% style="background-color:#f2f2f2; width:196px" %)Normally open 5V power supply.|(% style="background-color:#f2f2f2; width:114px" %)((( 1195 - 1196 - 1197 1197 OK 1198 1198 ))) 1199 1199 1200 1200 AT Command: AT+12VT 1201 1201 1202 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:443px" %)1127 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:443px" %) 1203 1203 |=(% style="width: 156px;background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 199px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 88px;background-color:#4F81BD;color:white" %)Response 1204 1204 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)((( 1205 - 1206 - 1207 1207 0 1208 1208 OK 1209 1209 ))) 1210 1210 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=0|(% style="background-color:#f2f2f2; width:199px" %)Normally closed 12V power supply.|(% style="background-color:#f2f2f2; width:83px" %)OK 1211 1211 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=500|(% style="background-color:#f2f2f2; width:199px" %)Close after a delay of 500 milliseconds.|(% style="background-color:#f2f2f2; width:83px" %)((( 1212 - 1213 - 1214 1214 OK 1215 1215 ))) 1216 1216 ... ... @@ -1297,15 +1297,12 @@ 1297 1297 bb: Each collection interval (s), the value is 1~~65535 1298 1298 cc: the number of collection times, the value is 1~~120 1299 1299 1300 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:510px" %)1221 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1301 1301 |(% style="background-color:#4f81bd; color:white; width:160px" %)Command Example|(% style="background-color:#4f81bd; color:white; width:215px" %)Function|(% style="background-color:#4f81bd; color:white" %)Response 1302 1302 |(% style="background-color:#f2f2f2; width:160px" %)AT+STDC=?|(% style="background-color:#f2f2f2; width:215px" %)Get the mode of multiple acquisitions and one uplink.|(% style="background-color:#f2f2f2" %)1,10,18 1303 1303 OK 1304 1304 |(% style="background-color:#f2f2f2; width:160px" %)AT+STDC=1,10,18|(% style="background-color:#f2f2f2; width:215px" %)Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|(% style="background-color:#f2f2f2" %)((( 1305 - 1306 - 1307 1307 Attention:Take effect after ATZ 1308 - 1309 1309 OK 1310 1310 ))) 1311 1311 |(% style="background-color:#f2f2f2; width:160px" %)AT+STDC=0, 0,0|(% style="background-color:#f2f2f2; width:215px" %)((( ... ... @@ -1315,10 +1315,7 @@ 1315 1315 1316 1316 1317 1317 )))|(% style="background-color:#f2f2f2" %)((( 1318 - 1319 - 1320 1320 Attention:Take effect after ATZ 1321 - 1322 1322 OK 1323 1323 ))) 1324 1324