From version < 123.17 >
edited by Xiaoling
on 2025/04/01 17:17
To version < 125.1 >
edited by Xiaoling
on 2025/04/01 17:42
>
Change comment: Uploaded new attachment "image-20250401174215-1.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -678,7 +678,6 @@
678 678  IN1_pin_level& IN2_pin_level& Exti_pin_level&Exti_status
679 679  )))|(% style="width:86px" %)Unix Time Stamp
680 680  
681 -
682 682  IN1_pin_level & IN2_pin_level & Exti_pin_level & Exti_status:
683 683  
684 684  [[image:image-20250117104847-4.png]]
... ... @@ -1286,18 +1286,18 @@
1286 1286  
1287 1287  Measure the corresponding current of the sensor when the liquid depth is 2.04m and 0.51m.
1288 1288  
1289 -Calculate scale factor
1288 +Calculate scale factor:
1290 1290  Use these two data to calculate the current and depth scaling factors:(7.888-5.035)/(2.04-0.51)=1.86470588235294
1291 1291  
1292 -Calculation formula
1291 +Calculation formula:
1293 1293  
1294 1294  Use the calibration formula:(Current current - Minimum calibration current)/Scale factor + Minimum actual calibration height
1295 1295  
1296 -Actual calculations
1295 +Actual calculations:
1297 1297  
1298 1298  Use this formula to calculate the value corresponding to the current at a depth of 1.5 meters: (6.918-5.035)/1.86470588235294+0.51=1.519810726
1299 1299  
1300 -Error
1299 +Error:
1301 1301  
1302 1302  0.009810726
1303 1303  
image-20250401174215-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +42.3 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0