<
From version < 123.16 >
edited by Xiaoling
on 2025/04/01 17:15
To version < 125.2 >
edited by Xiaoling
on 2025/04/01 18:07
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -678,7 +678,6 @@
678 678  IN1_pin_level& IN2_pin_level& Exti_pin_level&Exti_status
679 679  )))|(% style="width:86px" %)Unix Time Stamp
680 680  
681 -
682 682  IN1_pin_level & IN2_pin_level & Exti_pin_level & Exti_status:
683 683  
684 684  [[image:image-20250117104847-4.png]]
... ... @@ -1187,8 +1187,6 @@
1187 1187  OK
1188 1188  |(% style="background-color:#f2f2f2; width:154px" %)AT+PROBE=0003|(% style="background-color:#f2f2f2; width:269px" %)Set water depth sensor mode, 3m type.|(% style="background-color:#f2f2f2" %)OK
1189 1189  |(% style="background-color:#f2f2f2; width:154px" %)(((
1190 -
1191 -
1192 1192  AT+PROBE=000A
1193 1193  )))|(% style="background-color:#f2f2f2; width:269px" %)Set water depth sensor mode, 10m type.|(% style="background-color:#f2f2f2" %)OK
1194 1194  |(% style="background-color:#f2f2f2; width:154px" %)AT+PROBE=0064|(% style="background-color:#f2f2f2; width:269px" %)Set water depth sensor mode, 100m type.|(% style="background-color:#f2f2f2" %)OK
... ... @@ -1288,18 +1288,18 @@
1288 1288  
1289 1289  Measure the corresponding current of the sensor when the liquid depth is 2.04m and 0.51m.
1290 1290  
1291 -Calculate scale factor
1288 +Calculate scale factor:
1292 1292  Use these two data to calculate the current and depth scaling factors:(7.888-5.035)/(2.04-0.51)=1.86470588235294
1293 1293  
1294 -Calculation formula
1291 +Calculation formula:
1295 1295  
1296 1296  Use the calibration formula:(Current current - Minimum calibration current)/Scale factor + Minimum actual calibration height
1297 1297  
1298 -Actual calculations
1295 +Actual calculations:
1299 1299  
1300 1300  Use this formula to calculate the value corresponding to the current at a depth of 1.5 meters: (6.918-5.035)/1.86470588235294+0.51=1.519810726
1301 1301  
1302 -Error
1299 +Error:
1303 1303  
1304 1304  0.009810726
1305 1305  
... ... @@ -1322,10 +1322,34 @@
1322 1322  
1323 1323  = 8. Order Info =
1324 1324  
1322 +== 8.1 Thread Installation Type & Immersion Type Pressure Sensor ==
1325 1325  
1326 1326  
1325 +Part Number: **PS-NB-Txx-YY or PS-NB-Ixx-YY**
1326 +
1327 +**XX: Pressure Range and Thread Type **
1328 +
1329 +**YY: The default frequency band**
1330 +
1331 +* YY: Frequency Bands, options: EU433,CN470,EU868,IN865,KR920,AS923,AU915,US915
1332 +
1327 1327  [[image:image-20241021093209-1.png]]
1328 1328  
1335 +
1336 +== 8.2 Wireless Differential Air Pressure Sensor ==
1337 +
1338 +
1339 +Part Number: **PS-NB-Dxx-YY**
1340 +
1341 +**XX: Differential Pressure Range**
1342 +
1343 +**YY: The default frequency band**
1344 +
1345 +* YY: Frequency Bands, options: EU433,CN470,EU868,IN865,KR920,AS923,AU915,US915
1346 +
1347 +[[image:image-20250401174215-1.png||height="486" width="656"]]
1348 +
1349 +
1329 1329  = 9. ​Packing Info =
1330 1330  
1331 1331  
image-20250401174215-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +42.3 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0